MAURY USCG vessel records
← All vessels

PAC ALKAID

PAC ALKAID is a 2003 freight ship. The Coast Guard has recorded 17 inspections since 2016, most recently in April 2020, along with 17 deficiencies and 6 operational controls, 1 with no removal date recorded.

Records from 2016 to 2020. Most recent: inspection, 7 April 2020.

Built
2003
Last inspected
7 April 2020
Documentation
Not in the documentation file of 10 August 2026
Controls
1 with no removal date recorded

Identity

9265914
665554
Flag
SINGAPORE
Maury page id
psix-665554

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded2
Years with a record 5 calendar years (2016–2020)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it10630 - Convention (Subpart B), Net Ton
38046 - Displacement, Metric Ton
27465 - Dead Weight, Metric Ton
20471 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 17

7 April 2020 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6936747
5 April 2020 Ballast Water Examination · PSC A
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6935079
26 March 2020 Administrative Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6931802
23 March 2020 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6930439
17 March 2020 PSC B
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6924729
6 April 2019 Explosive Handling Operation-Commercial
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6670255
4 April 2019 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6655437
26 November 2018 ISPS III Exam · NPV Safety Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6586519
5 November 2018 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6574528
3 June 2018 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6432784
29 December 2017 ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6328655
20 August 2017 In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6245785
20 August 2017 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6247548
27 March 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6112426
16 March 2017 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6105522
10 June 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5903564
9 January 2016 PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5793972

Deficiency record · 17

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 March 2020 Resolved
Satisfactory means (in the form of guard rails, lifelines, etc) shall be provided for the protection of the crew in getting to and from their quarters, the machinery space, and all other parts used in the necessary work of the ship. PSCO noticed two wasted and detached guard rails on the port and stbd side of the #3 cargo hold. ICLL(88) I/25(4) 50A/C
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2020
Resolved 26 March 2020
Resolution: Reviewed and accepted class report attesting to proper repairs.
09 - Working and Living Conditions › 091 - Living Conditions › Cold room
Issued 17 March 2020 Resolved
The condition of the ship shall be maintained to comform witht he present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. PSCO pbserved the drip tray in the refrigerated chambers was corroded and nolonger secured to the overhead, posing an overhead hazard. Additionally, the temperature sensorsthat open the valved to the refrigeration lines were improperly installed, exposed, and ziptied to the piping system. 74SOLAS(14) I/11 50A/C
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2020
Resolved 26 March 2020
Resolution: Reviewed and accepted outstanding condition issued by ABS 26Mar2020. See report in documents for details.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 17 March 2020 Resolved
Every liferaft shall be stowed with its painter permanently attached to the ship. PSCO observed that the painter to the forward liferaft was not attached. 74 SOLAS (14) III/13.4.1 10C
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 17 March 2020
Resolved 31 March 2020
Resolution: Painter line reattached.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 March 2020 Resolved
All steering gear components and the rudder stock shall be of sound and reliable construction. PSCO noticed fixed hydraulic fluid storage tank for the steering gear was leaking, creating a puddle on the deck. 74SOLAS(04) II-1/20.2.1 17A/C
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 April 2020
Resolved 26 March 2020
Resolution: Class Survey report provided
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 17 March 2020 Resolved
A portable foam applicator unit shall consist of an air foam nozzle of an inductor type capable of being connected to the fire main by fire hose. The nozzle shall be capable of producing effective foam suitable for extinguishing an oil fire. PSCO noted kinked discharge hose on the portable foam applicator unit by the engine room escape tunnel and kinked, as well as, cracked. Discharge hose on foam applicator by the purifier room which would prevent the effective production of foam in the event of a fire. 74 SOLAS(01)II-2/6.4 17A/C
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 March 2020
Resolved 18 March 2020
Resolution: Vessel provided Class report with mitigating conditions. Action changed from 17 to 40.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 17 March 2020 Resolved
The steering gear compartments shall include handrails and gratings or toehr non slip surfaces to ensure suitable working conditions in the event of a hydraulic leakage. PSCO noted broken, raised gratinfs in multiple locations in the steering gear room, creating unsuitable working conditions. 74SOLAS(04)II-1/29.13.2 16A/C
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2020
Resolved 26 March 2020
Resolution: Reviewed and accepted class report attesting to proper repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 March 2020 Resolved
The machinery boiler and other pressure vessels shall be so installed and protected as to reduce to a minimum any danger to the person onboard, due regard being paid to moving parts, hot surfaces, and other hazards. PSCO noted missing exhaust pipe lagging on the #1 and #3 ship service generators (SSDG). Additionally PSCO noted an exhaust leak on the #2 SSDG. 74 SOLAS (04)II – 1/26 17A/C
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 March 2020
Resolved 26 March 2020
Resolution: Class Survey report provided.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 17 March 2020 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. PSCO noted multiple housings fractured and or hanging loose on the engine room light fixtures on the upper platform, outside the purifier room, and in the back of the engine room control room. 74SOLAS(14) I/11(a) 50A/C
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2020
Resolved 26 March 2020
Resolution: Reviewed and accepted outstanding condition issued by ABS 26Mar2020. See report in documents for details.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 March 2020 Resolved
After survey of the ship under regulations 7, 8, 9, or 10 has been completed, no change shall made in the structural arrangements, machinery equipment and other items covered by the survey without the sanction of the administration. PSCO noted the fuel oil drain pipe to the (Low Sulfur Marine Grade Oil) LSMGO tank was found disconnected and laying on the deck. 74SOLAS(14)I/11(b) 17A/C
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 March 2020
Resolved 26 March 2020
Resolution: Class Survey report provided.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 17 March 2020 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. PSCO observed a container of Amergy 222 (UN 3082) in the steering gear room to be distorted and leaking onto the deck grating creating a hazard to the crew. 74SOLAS(14) I/11(a) 17A/C
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 March 2020
Resolved 26 March 2020
Resolution: Class Survey report provided.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 17 March 2020 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. PSCO noted the passageway to the engine room boiler platform was found to have cracking concrete on the deck and concreet inset at the base of the door, creating a tripping hazard. 74SOLAS(14) I/11(a) 50A/C
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2020
Resolved 26 March 2020
Resolution: Reviewed and accepted outstanding condition issued by ABS 26Mar2020. See report in documents for details.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 17 March 2020 Resolved
The purpose of this regulation is to maintain and monitor the effectivemess of the fire safety measures the ship is provided with. For this purpose, the following functional requirements shall be met. Fire protection systems and firefighting systems and appliances shall be maintained ready for use. During spot check of the emergency generator, the PSCO discovered the switchboard in the manual selection mode. Although posted instructions in the space stated is should have been left in the automatic position prior to securing the space. Additionally, during testing of the quick closing arangements, it was noted the generators fuel oil valvecould not secure the generator. furthermore, the piping bracket which holds the wire rope that operates the valve (in the event of fire) broke away from the bulkhead when the crewmember tested. it. Two attempts by crew to repair valve without success. PSCO believes that these arrangements present a hazardous condition onboard in the event of fire or emergency. 74SOLAS(14)II-2/14.1.1 30A/C
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 17 March 2020
Resolved 26 March 2020
Resolution: Class Survey report provided.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 17 March 2020 Resolved
The company should establish procedureds to ensure that the ship in maintained in accordance with the provisions of the relevant rules and regulations established by the company. Due to the objective evidence in the deficiencies listed herein, the vessel is not in substantial compliance with the relevant conventions. The COTP questions the adequacy and/or implementation of the vessels SMS under the ISM codeAn external audit is recommended to be conducted within 30 days by the Flag or RO to determine whether the ship is operating in accordance with the ISM Code. Provide decision to USCG prior to departure from port. 74SOLAS(14) XI-1/4.1 ISM Code 10.1 30A/C
Condition: Improper Installation
Action required: 30 - Ship detained
Due 17 April 2020
Resolved 26 March 2020
Resolution: Reviewed and accepted class report attesting to the external audit being carried out. See documents for details.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 29 December 2017 Resolved
0715-Fire fighting appliances(Detection)- The condition of the ship and its equipment shall be mantained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to ship or persons on board. PSCO observed the fire control panel displayed a fault which rendered the general alarm inoperable. SOLAS 74 (2001) I/11(a) 17(a)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 January 2018
Resolved 3 June 2018
Resolution: Recieved Class Report, Tech Report and Flag Dispensation letter attesting to the successful repair of the fire control panel.
Lifesaving › Inflatable Liferafts › Painter
Issued 29 December 2017 Resolved
0620-Inflatable liferafts- Each liferaft or group of liferafts shall be stowed with a float free arrangement complying with requirements of paragraph 4.1.6 of the code so that each floats free and if, inflatable, inflates automatically when the ship sinks. PSCO observed the liferaft inflation line (painter) was incorrectly attached directly to the liferaft cradle. SOLAS 74 (2001) III/13.4.2 10(c)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 December 2017
Resolved 29 December 2017
Resolution: PSCO observed Crew re instaled the painter correctly and following manufactures instructions.
Lifesaving › Launching Appliances › Davit
Issued 29 December 2017 Resolved
0635-Launch arrangements for rescue boat- Launching and embarkation appliances complying with the requirements of section 6.1 of the code shall be provided for all survival craft. Where davit arms are recovered by power safety devices shall be fitted wich will automatically cut off power before the davit arms reach the stops. PSCO observed limit switch on winch utilized for rescue boat release hoisting inoperable. SOLAS 74 (2001) III/16.1 10(C)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 December 2017
Resolved 29 December 2017
Resolution: PSCO Observed crew replace the limit switch and properly operate the winch.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 16 March 2017 Resolved
The conditin of the ship and its equipment shal be maintained....to proceed to sea without danger to the ship or persons on board. Vessel had damage done to cargo hold #2 due to bad weather making the cargo shift while transiting.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 March 2017
Resolution: Received Class Survey attesting to Cargo Hold Damage

Ownership record