PAC ALKAID is a 2003 freight ship. The Coast Guard has recorded 78 inspections since 2004, most recently in April 2020, along with 39 deficiencies and 27 operational controls, 2 with no removal date recorded.
Records from 2004 to 2020. Most recent: inspection, 7 April 2020.
- Built
- 2003
- Last inspected
- 7 April 2020
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 39 recorded · 0 without a recorded resolution
- Controls
- 2 with no removal date recorded
Identity
9265914 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
S6DU6
665554
Flag
SINGAPORE
—
Maury page id
psix-665554
Inspections, by type
…with no type recorded28
Years with a record
15 calendar years (2004–2020)
The 78 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it10630 - Convention (Subpart B), Net Ton
38046 - Displacement, Metric Ton
27465 - Dead Weight, Metric Ton
20471 - Convention (Subpart B), Gross Ton
38046 - Displacement, Metric Ton
27465 - Dead Weight, Metric Ton
20471 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 78
7 April 2020
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6936747
5 April 2020
Ballast Water Examination · PSC A
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6935079
26 March 2020
Administrative Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6931802
23 March 2020
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6930439
17 March 2020
PSC B
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6924729
6 April 2019
Explosive Handling Operation-Commercial
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6670255
4 April 2019
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6655437
26 November 2018
ISPS III Exam · NPV Safety Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6586519
5 November 2018
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6574528
3 June 2018
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6432784
29 December 2017
ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6328655
20 August 2017
In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6245785
20 August 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6247548
27 March 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6112426
16 March 2017
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6105522
10 June 2016
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5903564
9 January 2016
PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5793972
3 September 2015
PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5228795
22 August 2015
MARPOL Annex I Examination · PII Safety Exam · ISPS II Exam · Ballast Water Examination · Administrative Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5219712
27 June 2014
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 4901323
27 June 2014
PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4901872
25 December 2011
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4213826
23 December 2011
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 4208690
23 December 2011
COE-Offshore
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4252461
16 August 2011
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4117246
15 August 2011
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4115952
12 August 2011
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 4116449
10 August 2011
ISPS I Exam · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4111027
10 August 2011
COE-Offshore
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4113171
9 August 2011
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 4105975
26 November 2010
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3899175
21 November 2010
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3895823
18 November 2010
ISPS I Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 3893836
17 November 2010
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3893606
9 March 2010
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3692398
4 March 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3689604
26 February 2010
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3686837
22 February 2010
Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3680330
21 February 2010
ISPS I Exam · PII Safety Exam
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 3683695
8 July 2009
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3528430
8 July 2009
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3528449
3 July 2009
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 3514333
21 February 2009
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3421613
18 February 2009
ISPS I Exam · PII Safety Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3414815
17 February 2009
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 3416016
6 November 2008
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3358411
5 November 2008
ISPS I Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3357767
4 November 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3357049
27 October 2008
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 3348831
11 July 2008
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3264854
2 July 2008
ISPS I Exam · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3244073
2 July 2008
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 3252936
26 February 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3153588
26 February 2008
ISPS III Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · Ballast Water Examination · PI Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3153831
4 February 2008
ISPS II Exam · PII Safety Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3134127
1 February 2008
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 3134472
2 October 2007
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 3067229
4 June 2007
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 2944608
5 February 2007
MARPOL Annex V Examination · MARPOL Annex I Examination · Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2866774
1 February 2007
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2865500
25 January 2007
Random ISPS/MTSA/PSC
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2859643
9 October 2006
Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 2796882
14 September 2006
Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2777926
11 September 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2776000
5 May 2006
MARPOL Annex V Examination · MARPOL Annex I Examination · Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2640679
14 April 2006
PII Safety Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2624630
3 January 2006
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2560162
23 August 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2472872
19 August 2005
ISPS II Exam
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2464637
18 April 2005
NPV Safety Exam
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2336796
9 September 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2192630
9 September 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2361104
8 September 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2190715
2 September 2004
Random ISPS/MTSA/PSC
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2184051
4 May 2004
MTSA/ISPS Verification · Re-Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2059170
28 April 2004
Administrative Inspection
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2059034
7 January 2004
Security Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1977973
6 January 2004
Annual Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1975043
Deficiency record · 39
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 March 2020
Resolved
Satisfactory means (in the form of guard rails, lifelines, etc) shall be provided for the protection of the crew in getting to and from their quarters, the machinery space, and all other parts used in the necessary work of the ship. PSCO noticed two wasted and detached guard rails on the port and stbd side of the #3 cargo hold.
ICLL(88) I/25(4)
50A/C
09 - Working and Living Conditions › 091 - Living Conditions › Cold room
Issued 17 March 2020
Resolved
The condition of the ship shall be maintained to comform witht he present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. PSCO pbserved the drip tray in the refrigerated chambers was corroded and nolonger secured to the overhead, posing an overhead hazard. Additionally, the temperature sensorsthat open the valved to the refrigeration lines were improperly installed, exposed, and ziptied to the piping system.
74SOLAS(14) I/11
50A/C
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 17 March 2020
Resolved
Every liferaft shall be stowed with its painter permanently attached to the ship. PSCO observed that the painter to the forward liferaft was not attached.
74 SOLAS (14) III/13.4.1
10C
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 March 2020
Resolved
All steering gear components and the rudder stock shall be of sound and reliable construction. PSCO noticed fixed hydraulic fluid storage tank for the steering gear was leaking, creating a puddle on the deck.
74SOLAS(04) II-1/20.2.1
17A/C
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 17 March 2020
Resolved
A portable foam applicator unit shall consist of an air foam nozzle of an inductor type capable of being connected to the fire main by fire hose. The nozzle shall be capable of producing effective foam suitable for extinguishing an oil fire. PSCO noted kinked discharge hose on the portable foam applicator unit by the engine room escape tunnel and kinked, as well as, cracked. Discharge hose on foam applicator by the purifier room which would prevent the effective production of foam in the event of a fire.
74 SOLAS(01)II-2/6.4
17A/C
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 17 March 2020
Resolved
The steering gear compartments shall include handrails and gratings or toehr non slip surfaces to ensure suitable working conditions in the event of a hydraulic leakage. PSCO noted broken, raised gratinfs in multiple locations in the steering gear room, creating unsuitable working conditions.
74SOLAS(04)II-1/29.13.2
16A/C
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 March 2020
Resolved
The machinery boiler and other pressure vessels shall be so installed and protected as to reduce to a minimum any danger to the person onboard, due regard being paid to moving parts, hot surfaces, and other hazards. PSCO noted missing exhaust pipe lagging on the #1 and #3 ship service generators (SSDG). Additionally PSCO noted an exhaust leak on the #2 SSDG.
74 SOLAS (04)II – 1/26
17A/C
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 17 March 2020
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. PSCO noted multiple housings fractured and or hanging loose on the engine room light fixtures on the upper platform, outside the purifier room, and in the back of the engine room control room.
74SOLAS(14) I/11(a)
50A/C
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 March 2020
Resolved
After survey of the ship under regulations 7, 8, 9, or 10 has been completed, no change shall made in the structural arrangements, machinery equipment and other items covered by the survey without the sanction of the administration. PSCO noted the fuel oil drain pipe to the (Low Sulfur Marine Grade Oil) LSMGO tank was found disconnected and laying on the deck.
74SOLAS(14)I/11(b)
17A/C
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 17 March 2020
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. PSCO observed a container of Amergy 222 (UN 3082) in the steering gear room to be distorted and leaking onto the deck grating creating a hazard to the crew.
74SOLAS(14) I/11(a)
17A/C
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 17 March 2020
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. PSCO noted the passageway to the engine room boiler platform was found to have cracking concrete on the deck and concreet inset at the base of the door, creating a tripping hazard.
74SOLAS(14) I/11(a)
50A/C
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 17 March 2020
Resolved
The purpose of this regulation is to maintain and monitor the effectivemess of the fire safety measures the ship is provided with. For this purpose, the following functional requirements shall be met. Fire protection systems and firefighting systems and appliances shall be maintained ready for use. During spot check of the emergency generator, the PSCO discovered the switchboard in the manual selection mode. Although posted instructions in the space stated is should have been left in the automatic position prior to securing the space. Additionally, during testing of the quick closing arangements, it was noted the generators fuel oil valvecould not secure the generator. furthermore, the piping bracket which holds the wire rope that operates the valve (in the event of fire) broke away from the bulkhead when the crewmember tested. it. Two attempts by crew to repair valve without success. PSCO believes that these arrangements present a hazardous condition onboard in the event of fire or emergency.
74SOLAS(14)II-2/14.1.1
30A/C
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 17 March 2020
Resolved
The company should establish procedureds to ensure that the ship in maintained in accordance with the provisions of the relevant rules and regulations established by the company. Due to the objective evidence in the deficiencies listed herein, the vessel is not in substantial compliance with the relevant conventions. The COTP questions the adequacy and/or implementation of the vessels SMS under the ISM codeAn external audit is recommended to be conducted within 30 days by the Flag or RO to determine whether the ship is operating in accordance with the ISM Code. Provide decision to USCG prior to departure from port.
74SOLAS(14) XI-1/4.1
ISM Code 10.1
30A/C
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 29 December 2017
Resolved
0715-Fire fighting appliances(Detection)- The condition of the ship and its equipment shall be mantained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to ship or persons on board. PSCO observed the fire control panel displayed a fault which rendered the general alarm inoperable. SOLAS 74 (2001) I/11(a) 17(a)
Lifesaving › Inflatable Liferafts › Painter
Issued 29 December 2017
Resolved
0620-Inflatable liferafts- Each liferaft or group of liferafts shall be stowed with a float free arrangement complying with requirements of paragraph 4.1.6 of the code so that each floats free and if, inflatable, inflates automatically when the ship sinks. PSCO observed the liferaft inflation line (painter) was incorrectly attached directly to the liferaft cradle. SOLAS 74 (2001) III/13.4.2 10(c)
Lifesaving › Launching Appliances › Davit
Issued 29 December 2017
Resolved
0635-Launch arrangements for rescue boat- Launching and embarkation appliances complying with the requirements of section 6.1 of the code shall be provided for all survival craft. Where davit arms are recovered by power safety devices shall be fitted wich will automatically cut off power before the davit arms reach the stops. PSCO observed limit switch on winch utilized for rescue boat release hoisting inoperable. SOLAS 74 (2001) III/16.1 10(C)
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 16 March 2017
Resolved
The conditin of the ship and its equipment shal be maintained....to proceed to sea without danger to the ship or persons on board. Vessel had damage done to cargo hold #2 due to bad weather making the cargo shift while transiting.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 3 September 2015
Resolved
0899 - Each transfer pipe system used for the transfer of oil or liquid hazardous material to or from a vessel with the capacity of 250 barrels or more must not leak under static pressure at least 1.5 times the maximum allowable working pressure annually. Chief engineer stated that last hydrostatic test of bunker lines was conducted using air as a medium. 33CFR156.170
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 22 August 2015
Resolved
1730 - Oil filtering equipment referred to in paragraph 2 of this regulation shall comply with paragraph 6 of this regulation. In addition, it shall be provided with alarm arrangements to indicate when this level cannot be maintained. See narrative and documents in activity 5219712 for full deficiency write up. 30abc
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 22 August 2015
Resolved
1420 - The bilge around the main engine is covered in excessive amounts of oil which poses a serious fire and safety hazard to the vessel and crew. In particular, large amounts of insulation and rags were found in the bilge to collect oily waste. 74 SOLAS (14) XI-1/4.1 17abc
Engineering › Sea-water System (primary cooling) › Piping
Issued 22 August 2015
Resolved
1499 - The seawater cooling delivery line from the sea chest to the fresh water heat exchanger is severely corroded and has multiple temporary repairs in place. Furthermore, the heat exchangers for the fresh water cooling have been altered to allow cross connecting of sea water inlet and discharge resulting from the corrosion of the sea water pipe.
74 SOLAS (04)
II-1/26.3.6 17 abc
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 22 August 2015
Resolved
1420 - The fuel delivery valve on the #3 HFO Storage Tank is leaking excessively; the crew has stuffed rags around the valve which poses a fire hazard to the vessel. 74 SOLAS (01)
II-2/15.2 17abc
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 22 August 2015
Resolved
0999 - Modified ball valve fitting to the Dirty Oil Tank hatch cover would not prevent the ingress of water into the engine room in the event of overfilling or flooding from the tank. 74 SOLAS (14)
I/11(a) 17abc
Electrical › Lighting (service) › Conductor
Issued 22 August 2015
Resolved
0950 - Cables and wiring shall be installed and supported in such a manner as to avoid chafing or other damage. Electrical wiring for lighting in engine room in way of the Marine Sanitation Device is secured with manila line and plastic ties. 74 SOLAS (04)
II-1/45.5.5 17 abc
Engineering › Steering Gear System › Power Unit
Issued 22 August 2015
Resolved
1499 - The fixed storage tank is leaking from the bottom of the sight glass. Crew has stuffed rags into the sight glass to control leaking. 74 SOLAS (04)
II-1/29.12.3 17abc
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 22 August 2015
Resolved
1420 - Signs of cleaning and work continue in void above #2 HFO Storage Tank. Crew claims ABS approved repairs to #2 HFO Storage Tank after damage in June 2015. Class to verify if void space contains fuel oil leaks from the fuel tank. 74 SOLAS (14) XI-1/4.1 17abc
Fire Fighting › Portable Foam Applicators › General
Issued 22 August 2015
Resolved
0720 - The 20 liter portable foam extinguishing system on the lower deck of the engine room was not ready for use. The foam agent had leaked out of the bottles and filled the containment box. Crew cleaned the box and replaced foam agent with spares on board.
Lifesaving › Immersion Suits › Readily Accessible
Issued 22 August 2015
Resolved
0663 - The immersion suit storage box in the engine control room was covered in old computer parts and was not available for immediate use. Crew cleaned the area and removed equipment that was in the way of life saving equipment. 74 SOLAS (14)
III/20.2 10c
Navigation › Piloting/Steering › Gyro Compass
Issued 9 March 2010
Resolved
Vessel reported an inoperative gyro compass.
Electrical › Lighting (service) › Lighting Fixture
Issued 21 February 2010
Resolved
COVERS ON LIGHT FIXTURES WERE NOT IN PLACE IN CREW ACCOMMODATIONS.
Electrical › Lighting (service) › Switch
Issued 21 February 2010
Resolved
HAD PLASTIC WRAPPED AROUND STERN LIGHT ELECTRICAL HOUSING AS WELL AS VENTILATION CONTROL BOXES.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 21 February 2010
Resolved
REPLACE DAMPENER SCREENS ON VENTILATION DUCTS. REPAIR INSULATION HOUSING ON EXHAUST.
Construction/Loadline › Hull › Side Shell
Issued 26 February 2008
Resolved
The side shell was inset and frame 26 is tripped. HFO tank was empty at the time of the allision.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 4 February 2008
Resolved
Deck in Reefer room is soft and rotted due to condensation dripping onto the deck. Ship is to make temporary repairs and make permanent repairs at dry dock.
Engineering › Fuel Oil Service System › Valve
Issued 1 February 2008
Resolved
Vessel is using improper procedure for drawing water from purifier sludge tank via unapproved valve. The draw line valve is to be removed/ blanked off and a tracking seal is to be installed and logged according to ships policy. Company to develop procedure for removing excess water from purifier sludge tank by installing fixed piping.
Personnel › Certificates/Documents/Licenses › License, Second Assistant Engineer
Issued 25 January 2007
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Personnel › Certificates/Documents/Licenses › License, Chief Engineer
Issued 25 January 2007
Resolved
Chief Engineer had only a fax copy of his Certificate of Endorsement from the Flag administration. Vessel is required to provide original.
Personnel › Certificates/Documents/Licenses › License, Second Assistant Engineer
Issued 25 January 2007
Resolved
Second Engineer received email copy of valid Certificate of Endorsement from the Flag administration. Vessel is required to provide original.
Pollution Prevention/Response › Prevention Equipment
Issued 4 May 2004
Resolved
Oily Water Seperator alarm for oily waste of greater than 15ppm does not function as per system design. However, the automatic stoppage device does function properly. Make repairs and prove satisfactory operation of the Oily Water Seperator system to the satisfaction of the attending class society. LEGACY COMPONENT DESC: Oily Water Separator Alarm