MAURY USCG vessel records
← All vessels

GEES BEND

GEES BEND is a 2004 passenger vessel (inspected). The Coast Guard has recorded 15 inspections since 2016, most recently in April 2026, along with 11 deficiencies and 1 casualty investigation in 2022.

Records from 2016 to 2026. Most recent: inspection, 6 April 2026.

Built
2004
Last inspected
6 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 6 April 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDC8693
665705
Flag
UNITED STATES
Maury page id
psix-665705

Documentation record

Registered dimensions (L × B × D)95.7 ft × 42.0 ft × 5.0 ft
Registered tonnagegross 86 / net 58
ITC dimensions (L × B × D)95.7 ft × 42.0 ft × 5.0 ft
ITC tonnagegross 153 / net 57
BuilderBONNER SHIPYARDS · WETUMPKA, AL, UNITED STATES · built 2004
Hull materialSteel
PropulsionElectric Motor
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portCAMDEN, AL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 16 April 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it57 - Convention (Subpart B), Net Ton
58 - Regulatory (Subpart C or D), Net Ton
153 - Convention (Subpart B), Gross Ton
86 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 15

6 April 2026 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8343729
28 March 2025 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8101495
9 April 2024 COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7892476
4 December 2023 Administrative Inspection · Internal Structural Exam · Hull Examination · Drydock Exam · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7833558
6 April 2023 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7663841
19 December 2022 Damage Survey · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7611132
18 December 2022 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7612503
4 April 2022 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7424038
14 April 2021 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7175351
8 June 2020 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6977833
15 September 2017 Plan Review "T" Boat · COI Inspection · Construction Oversight · Hull Examination · Deadweight Survey · Examination of Repairs · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6269696
21 August 2017 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6247763
25 October 2016 Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6029332
20 October 2016 Deficiency Check · Plan Review "T" Boat · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6027371
8 September 2016 DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5995834

Deficiency record · 11

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 April 2024 Resolved
Fire fighting annual servicing reports must show the accurate weight of each CO2 fixed cylinder. The weights for each cylinder (04) were inaccurate on the net weight. Provide a servicing report that reflects the correct weights.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2024
Resolved 3 May 2024
Resolution: New report with accurate tares provided by servicing company
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 18 April 2024 Resolved
Vessel master is required to have a FCC Marine Radio Operator Permit. master did not have a valid permit. Provide a valid FCC Marine Radio Operator Permit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2024
Resolved 3 May 2024
Resolution: Captain provided new operator permit
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 April 2024 Resolved
Portable fire extinguishers are required to be inspected monthly. Vessel's crew were unable to provide proof that the extinguishers were inspected monthly. Provide proof that the portable fire extinguishers are inspected monthly, IAW NFPA 10.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2024
Resolved 3 May 2024
Resolution: New process installed onboard using HELM for monthly extinguisher inspections
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 December 2023 Resolved
A vessel that is exposed to salt water not more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural examination at least once every five years. Vessel was in drydock at Metal Shark Boats in Bayou La Batre, AL but departed before outstanding items were verified by marine inspectors. These outstanding items were: 1. Stern void port side has bag on bilge suction 2. Void 5 from the stern has a RoxBlox that is not watertight, also has a bag on bilge suction. 3. Void 16 found frame and two tripping brackets wasted. 4. Stitch welding of longitudinal frames in engine room 5. 1st frame forward of aft bulkhead inboard in the port machinery space not attached. These items must be verified before DD/ISE credit can be given and deficiency cleared.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2024
Resolved 3 May 2024
Resolution: Met with vessel Rep [name withheld] to discuss testing of newly packed MCT, A procedure was agreed upon and testing was witnessed, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 December 2022 Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Vessel experienced a momentary loss of propulsion. Company is required to submit a report of findings and test of propulsion equipment, to the satisfaction on the Marine Inspector, prior to having any restrictions lifted. Written authorization of 835 clearance from local OCMI required prior to resuming operation.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 21 December 2022
Resolved 4 January 2023
Resolution: Troubleshooting performed by Marine Interface.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 April 2022 Resolved
Electrical shore tie aft connection bracket welds found broken.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2022
Resolved 28 April 2022
Resolution: Deficiency rectified. Shore tie box welded back to connection bracket
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 April 2022 Resolved
Marker light on port side life ring found broken.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2022
Resolved 28 April 2022
Resolution: Deficiency rectified. New Float Light installed and connected to Ring Bouy
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 15 September 2016 Resolved
Life buoy water light battery worked but expired, replace with correct battery.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 October 2016
Resolved 25 October 2016
Resolution: Water light battery purchased and working.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 15 September 2016 Resolved
Water light for life bouy needs corrosion clasp for attechment to life ring.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 October 2016
Resolved 25 October 2016
Resolution: Corrosion clasp installed.
Lifesaving › Lifejacket/PFD (Type IV) › Storage
Issued 15 September 2016 Resolved
Add 01 to number to stowage of adult life jackets. Needs to read 86 for proper markings.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 October 2016
Resolved 25 October 2016
Resolution: Proper stowage number of life jackets installed.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 15 September 2016 Resolved
Both fire fighting cylinders will be hydrostatic tested and filled with the odorizing unit to produce the scent of wintergreen.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 October 2016
Resolved 25 October 2016
Resolution: Bottles were hydro tested and stamped.

Casualty record · 1

18 December 2022Routine · role: Involved in a Marine Casualty · activity 7612503
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.