MAURY USCG vessel records
← All vessels

TELLURIDE

TELLURIDE is a 2003 tank ship. The Coast Guard has recorded 5 inspections since 2016, most recently in June 2018, along with 1 deficiency.

Records from 2016 to 2018. Most recent: inspection, 5 June 2018.

Built
2003
Last inspected
5 June 2018
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 5 June 2018
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2016–2018)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9256248
665745
Flag
MARSHALL ISLANDS
Maury page id
psix-665745

Documentation record

Tonnage as PSIX records it20395 - Convention (Subpart B), Net Ton
86126 - Displacement, Ton
72344 - Dead Weight, Ton
40763 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 5

5 June 2018 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6434643
21 February 2018 COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6354231
23 January 2017 COC-TVE Annual · ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6072749
10 August 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5968536
24 January 2016 ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5800412

Deficiency record · 1

Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 21 February 2018 Resolved
1830- The inert gas system shall be designed to the satisfaction of the Administration. The Deck water Seal Float switch is not operating as designed in accordance with the IGS manual chapter 12 Section 1.48.10 D.W.S low water level switch.74 SOLAS(2004 Cons Ed) II-2/5.5.1.1 FSS Code Ch 15.2.1.2 - Action Taken 40AC
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 June 2018
Resolution: Vessel provided Class report From Lloyds. Reference the attached report attesting to proper operation of the DWS.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.