Records from 2004 to 2007. Most recent: inspection, 23 May 2007.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 7
23 May 2007
Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2937780
5 April 2007
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2901998
4 April 2007
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2903961
30 March 2007
Administrative Inspection
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2898064
30 July 2006
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2725064
5 October 2004
PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2213630
8 January 2004
Annual Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1978572
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 5 April 2007
Resolved
All of the deck scupper plugs were inadequate. The wooden plugs do not create a seal and are rotted in some cases.
Action required: 15 - Rectify deficiencies by next port
Resolved 23 May 2007
Pollution Prevention/Response › Prevention Equipment › Portable Containment
Issued 5 April 2007
Resolved
The small discharge containment on all of the tank vents was wasted. The plugs are inadequate and do not create a seal due to the amount of rust.
Action required: 15 - Rectify deficiencies by next port
Resolved 23 May 2007
Engineering › Fuel Oil Service System › Tank
Issued 5 April 2007
Resolved
The aft bulkhead in the rudder trunk in the way of the bottom rung of the ladder was severely corroded. Fuel oil was found in the adjacent tank, and was observed permeating into the space.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 May 2007
Resolved 6 April 2007
Resolution: Class (NKK) provided satisfactory survey report and intentions for repair.
Engineering › Bilge Water Management System › Piping
Issued 30 July 2006
Resolved
Found crack in piping from waste oil tank to bilge. Repair crack to satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 March 2007
Resolution: See the attached class society report for details on repairs rectified.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 30 July 2006
Resolved
Found a cracked pipe on oily water separator. Repair crack to satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 March 2007
Resolution: See the attached class society report for details on repairs rectified.
Electrical › Lighting (service) › Lighting Fixture
Issued 30 July 2006
Resolved
Found loose electrical wire on light fixture in way of engine room door. Repair to satisfaction of class.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 March 2007
Resolution: See the attached class society report for details on repairs rectified.
Fire Fighting › Fire Main › Valves
Issued 30 July 2006
Resolved
Found leaking fire main valve at fire station for starboard life boat embarkation deck. Repair to satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 March 2007
Resolution: See the attached class society report for details on repairs rectified.
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 30 July 2006
Resolved
Found leak on emergency fire pump priming line. Repair to satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 March 2007
Resolution: See the attached class society report for details on repairs rectified.
Navigation › Piloting/Steering › Maneuvering Information Fact Sheet
Issued 1 January 2004
Resolved
Vessel missing Maneuvering Fact Sheet with warning statement on bridge.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 3 October 2004
Resolved 3 October 2004
Resolution: COMPLETED
Navigation › Piloting/Steering › Gyro Compass
Issued 1 January 2004
Resolved
Vessel needs to remove or update manufacturers maintenance label posted on steering stand. (Gyrocompass requires two year servicing due Jan 2003)
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 3 October 2004
Resolved 3 October 2004
Resolution: COMPLETED