MAURY USCG vessel records Sign in
← All vessels

ORLEANS

ORLEANS is a 2004 offshore supply vessel. The Coast Guard has recorded 31 inspections since 2004, most recently in March 2019, along with 12 deficiencies and 1 casualty investigation in 2007.

Records from 2004 to 2019. Most recent: inspection, 15 March 2019.

Built
2004
Last inspected
15 March 2019
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9315501 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDD3648
665896
Flag
UNITED STATES
366932390 (licence lapsed)
Maury page id
psix-665896

Inspections, by type

…with no type recorded1
Years with a record 14 calendar years (2004–2019)
The 31 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it797 - Convention (Subpart B), Net Ton
2045 - Convention (Subpart B), Gross Ton
2310 - Dead Weight, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDD3648MMSI 366932390 · cancelled · compulsorily equipped · granted 27 May 2016, cancelled 16 April 2021
WDB6886MMSI 366932390 · cancelled · compulsorily equipped · granted 18 March 2004, cancelled 8 August 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 31

15 March 2019 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6643075
25 June 2018 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6454969
11 June 2018 Administrative Inspection · ACP Annual Oversight · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6441411
14 June 2017 ACP Periodic Oversight · Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6175466
13 June 2017 Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6182542
16 November 2016 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6042682
23 March 2016 MTSA/ISPS Verification · Annual Inspection · Administrative Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5839320
13 March 2014 MTSA/ISPS Verification · Administrative Inspection · ACP COI Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4815387
7 June 2012 ACP Annual Oversight
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4335794
23 May 2012 Administrative Inspection · ACP Annual Oversight · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4320356
3 August 2011 MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4089158
18 November 2010 DAPI Audit · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3894608
10 July 2009 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3530157
23 September 2008 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3330691
6 August 2008 ACP Annual Oversight · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3290521
16 November 2007 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3109986
18 June 2007 Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2965615
2 June 2007 Damage Survey · Permit to Proceed
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2952578
2 June 2007 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3027024
6 September 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2770489
18 May 2006 ACP Annual Oversight · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2656093
7 March 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2597919
11 August 2005 ACP Annual Oversight
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2459329
14 July 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2426317
29 June 2005 MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2407512
7 June 2005 MARPOL Annex II Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2382918
17 December 2004 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2261114
30 June 2004 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2116588
10 June 2004 Administrative Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2100044
9 March 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2022098
10 February 2004 Construction Oversight · Initial Construction-Excluding Oversight · ACP COI Oversight · Initial Certification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2003566

Deficiency record · 12

Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 18 November 2010 Resolved
DOT Drug testing background checks not complete as per 49 CFR PART 40.25.
Action required: 705 - Other - as specified
Due 18 December 2010
Resolved 26 January 2011
Resolution: Cleared by SECTOR New Orleans DAPI.
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 18 November 2010 Resolved
Company not testing vessels overseas and is not testing all crewmembers in safety sensitive positions.
Action required: 705 - Other - as specified
Due 18 December 2010
Resolved 26 January 2011
Resolution: Cleared by SECTOR New Orleans DAPI.
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 18 November 2010 Resolved
All required personnel are not in testing pool. Also covered employees list with company that conducts random not up to date.
Action required: 705 - Other - as specified
Due 18 December 2010
Resolved 26 January 2011
Resolution: Cleared by SECTOR New Orleans DAPI.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 18 November 2010 Resolved
EAP training for both crewmembers and supervisors not completed.
Action required: 705 - Other - as specified
Due 18 December 2010
Resolved 26 January 2011
Resolution: Cleared by SECTOR New Orleans DAPI.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 6 August 2008 Resolved
Doors fitted in boundry bulkheads of machinery spaces of catagory A shall be reasonably gastight and self-closing in accordance with SOLAS Chapter II-2 Regulation 9 paragraph 4.2.1
Action required: 705 - Other - as specified
Due 6 September 2008
Resolved 20 November 2008
Construction/Loadline › Hull › Bottom Plating
Issued 2 June 2007 Resolved
Vsl has a fracture in the stbd fuel tank and a fracture in the forepeak due to striking the rocks on the Cameron, La jetties.
Action required: 705 - Other - as specified
Resolved 13 June 2007
Resolution: Attended vsl to inspect completed repairs.
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 14 May 2004 Resolved
Submit revised Automation Test Procedures to reflect installed machinery and their set points to ABS as required by the Section VIII, Cite A-11, of the US supplement to ABS Rules for Steel Vessels Under 90 Meters in Length. LEGACY COMPONENT DESC: Automation Test Procedures
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 July 2004
Resolved 30 June 2004
Resolution: Cleared deficiency pending vessel being evaluated for reduced manning for unattended machiinery space.
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 14 May 2004 Resolved
Provide on board vessel, fire maintenance plan as required by SOLAS 74 (Amended) II-2/14. LEGACY COMPONENT DESC: Fire Maintenance Plan
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 14 July 2004
Resolved 30 June 2004
Resolution: Reviewed fire maintenance plan for sister vessel. On board verification of plan to be done during annual inspection.
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 14 May 2004 Resolved
Provide on board vessel, fire fighting training manual as required by SOLAS 74 (Amended) II-2/15. LEGACY COMPONENT DESC: Fire Fighting Training
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 July 2004
Resolved 9 August 2007
Resolution: Capt provided on board vessel , fire fighting training manual required by SOLAS 74.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 14 May 2004 Resolved
Provide in the engine room as required by SOLAS 74 (Amended) II-2/7, smoke detector(s) in the engine room to detect rapid onset of fire in that space. LEGACY COMPONENT DESC: Smoke Detectors
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 July 2004
Resolved 30 June 2004
Resolution: Cleared deficiency since the SOLAS requirement is for unattended machinery spaces.
Documentation › Certificates/Documents
Issued 14 May 2004 Resolved
Provide evidence that chemical testing of vessel personnel have been conducted as required by 46 CFR Part 16. LEGACY COMPONENT DESC: Chemical Testing
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 June 2004
Resolved 10 June 2004
Resolution: Received documentation that the company has a drug testing program set up thru an MRO and all crew members received pre-employment drugs tests, which were negative.
Lifesaving › Embarkation Appliances/Stations › Designated Location
Issued 14 May 2004 Resolved
Provide muster lists as required by SOLAS 74 (Amended) III/8. LEGACY COMPONENT DESC: Muster List
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 July 2004
Resolved 9 August 2007
Resolution: Capt provided crew muster list as required by SOLAS 74.

Casualty record · 1

2 June 2007Routine · role: Involved in a Marine Casualty · activity 3027024
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.