MAURY USCG vessel records Sign in
← All vessels

TEXAS HIGHWAY

TEXAS HIGHWAY is a 2003 freight ship. The Coast Guard has recorded 29 inspections since 2004, most recently in April 2026, along with 4 deficiencies.

Records from 2004 to 2026. Most recent: inspection, 7 April 2026.

Built
2003
Last inspected
7 April 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9272890 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
665971
Flag
JAPAN
—
Maury page id
psix-665971

Inspections, by type

…with no type recorded2
Years with a record 17 calendar years (2004–2026)
The 29 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it16637 - Convention (Subpart B), Net Ton
32475 - Displacement, Metric Ton
17481 - Dead Weight, Metric Ton
55458 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 29

7 April 2026 PSC B
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8340590
17 September 2024 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8004012
19 April 2023 PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7671278
30 September 2022 PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7565812
6 September 2019 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6796536
8 February 2019 ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6619746
30 July 2018 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6489059
27 June 2017 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6187794
11 May 2017 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6141458
1 June 2016 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5893916
28 April 2016 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5864566
6 November 2015 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5758654
13 October 2014 Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5001415
15 May 2014 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4859184
20 June 2012 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4348355
26 August 2011 Deficiency Check · Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4123561
25 September 2008 ISPS III Exam · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3332497
5 March 2008 ISPS II Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3158792
15 September 2007 Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3058175
10 May 2006 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2645681
26 November 2005 PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2541015
24 September 2005 ISPS II Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2497446
6 August 2005 In-Service Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2453246
6 May 2005 Ballast Water Examination · MARPOL Annex I Examination · Random ISPS/MTSA/PSC
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2350957
8 February 2005 PII Safety Exam · ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2287153
12 July 2004 ISPS II Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2127202
30 March 2004 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2033717
15 January 2004 Ballast Water Examination · Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1979827
15 January 2004 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1985473

Deficiency record · 4

Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 28 April 2016 Resolved
MARPOL 73/78 Annex VI/Reg 5.4 40AC The equip shall be maintained to conform w/provisions of this Annex & no changes shall be made in equip/systems/fittings/arrangements/or material covered by the survey without express approval of the Admin. Incinerator has crack in metal framing compromising integrity of system.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 May 2016
Resolution: the two cracks on the shell plate of the incinerator was repaired and confirmed by the class surveyor.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 28 April 2016 Resolved
74 SOLAS(09)II-I/43.2 10C The electrical power available shall be sufficient to supply all those services that are essential for safety in an emergency, due regard being paid to such services as may be operated simultaneously. Emergency generator unable to conduct a simulated blackout due to hunting. Fuel filters were replaced and the e-gen was retested satifactory.
Action required: 705 - Other - as specified
Due 28 April 2016
Resolved 28 April 2016
Resolution: Fuel filters replaced, test satisfactory.
Lifesaving › Lifeboat › Hull
Issued 6 November 2015 Resolved
74 SOLAS (14) CH III REG 20.2 - 17ac : Before the ship leaves port, and at all times during the voyage all lifesaving appliances shall be in working order, and ready for immediate use. Port and stbd lifeboats have cracks in their hulls in way of aft davit blocks.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 November 2015
Resolved 7 November 2015
Resolution: VESSEL HAS SUBMITTED A SATISFACTORY CLASS REPORT.
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 22 August 2011 Resolved
0704-Firefighting pumps, in cargo ships, if a fire in any one compartment could put all the pumps out of action, these shall be an alternative means consisting of an emergency fire pump complying with the provisions of the fire safety code. Vessel's emergency fire pump would not produce any fire fighting water. Solas 74 (04) Ch II-2 Reg 10 2.2.3.1.-17c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 August 2011
Resolution: CG PSC inspector from Sector Jacksonville verified and attested to the emergency fire pump working properly.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.