← All vessels
CHAILEASE GLORY
CHAILEASE GLORY is a 2003 freight ship. The Coast Guard has recorded 26 inspections since 2004, most recently in July 2021, along with 9 deficiencies and 7 operational controls.
Records from 2004 to 2021. Most recent: inspection, 12 July 2021.
- Built
- 2003
- Last inspected
- 12 July 2021
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 9 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9286889 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
A8CB5
666263
Flag
LIBERIA
—
Maury page id
psix-666263
Inspections, by type
…with no type recorded9
Years with a record
13 calendar years (2004–2021)
The 26 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it25754 - Convention (Subpart B), Net Ton
86824 - Displacement, Metric Ton
76633 - Dead Weight, Metric Ton
39727 - Convention (Subpart B), Gross Ton
86824 - Displacement, Metric Ton
76633 - Dead Weight, Metric Ton
39727 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 26
12 July 2021
PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7244169
31 October 2020
PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7080859
29 May 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6698667
13 May 2019
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6676632
31 January 2017
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6080604
2 November 2016
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6031727
18 October 2015
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5745292
20 October 2014
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5008430
8 October 2014
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4998178
17 February 2011
Deficiency Check · ISPS I Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 3940712
15 February 2011
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 3941675
22 October 2010
ISPS I Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3869121
17 October 2010
Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 3868587
1 March 2010
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3683717
27 February 2010
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3684489
12 July 2007
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2992417
12 October 2006
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2799905
13 April 2006
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2624052
6 April 2006
PII Safety Exam · ISPS II Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2618115
13 April 2005
NPV Safety Exam
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2325885
12 April 2005
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2332292
15 January 2005
Deficiency Check · ISPS II Exam · Ballast Water Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2275414
18 January 2004
Annual Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1987583
18 January 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1989101
17 January 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1989106
13 January 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1988199
Deficiency record · 9
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 31 October 2020
Resolved
01-11129-BEFORE A SHIP LEAVES PORT AND ALL TIMES DURING THE VOYAGE, ALL LIFESAVING APPLIANCES SHALL BE IN WORKING ORDER AND READY FOR IMMEDIATE USE. PORT LIFEBOAT FAILED TO START ENGINE. 74SOLAS(14) III/20.2 17AC
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 May 2019
Resolved
Maintenance, testing, and inspections shall be carried out based on guidelines developed by the organization. Testing a sample monthly of detectors and manual call points so that all devices have been tested within five years. PSCO observed crew's inability to test heat detectors due to lack of procedures and familarity. Records could not indicate the last time a heat detector was tested. In addition, records showed that crew tested detectors location in the same location for the last 2 years due to an error in the maintenance book that incorrectly marked the location of all smoke detectors in the accommodation spaces, thus, making it impractical to meet the 5 year requirement due to lack of testing in engine room.
74SOLAS cons. (14) II-2/14.2.2.1
Circ 1432/5.10
50AC
Deck/Cargo › Mooring/Anchoring › Anchoring Arrangement
Issued 2 November 2016
Resolved
0999-Other (safety in general)-The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship will remain fit to proceed to sea. PSCO observed an apparent leak in the starboard side anchor wash that resulted in approximately 60 gallons of water on the deck in the forward bos'n stores. 74SOLAS(2014) I/11(a) 16a
Fire Fighting › Structural - A Class Divisions › Doors
Issued 2 November 2016
Resolved
0750-Fire Prevention-The following fire protection systems shall be in good working order so as to ensure their required performance if a fire occurs. PSCO observed 01 class A fire door on the B deck stair well was not operating as designed or closing properly. Additionally, PSCO observed air vent closures in the paint locker were degraded and could not be secured. 74 SOLAS (2014) II-2/14.2.1.1.1
Engineering › Fuel Oil Service System › Filter
Issued 2 November 2016
Resolved
0750-Fire Prevention-The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all resects will remain fit to proceed to sea. PSCO observed leaking on the fuel filter of the MDE F/O system and in the GE F/O #2 strainer. 74 SOLAS (2014) I/11(a) 16a
Deck/Cargo › Holds/Tanks › Cargo Tank Drainage
Issued 2 November 2016
Resolved
Remote control system on bridge for dewartering of fore peak tank was found malfunctioning due to the electro-hydraulic pump inoperative. Dispensation was granted by the flag administration to expire 04 January 2017.
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 8 October 2014
Resolved
2120-Garbage-Every ship 100 GT and above shall carry a garbage management plan. It shall provide procedures for storing of garbage. Vessel's plan provides a table that should state where garbage is stored. Said table was blank, and does not specify where garbage shall be stored. Provide clarification and storage locations of garbage from Company, with concurrence from Class-MARPOL 73/78 Annex V/10
Communications › Radio Communications › EPIRB
Issued 1 March 2010
Resolved
EPIRB is not responding to test mode, EPIRB must be fully operational and respond to manual test. 74SOLAS IV/7/1/6 (2004 cons ed) to the satisfaction of USCG.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 18 January 2004
Resolved
The vessel's port anchor windlass is in-operable. The coupling to engage the wildcat is frozen in place on the shaft. The anchor can be lowered but not picked up. Repairs to be made to the satisfaction of class. LEGACY COMPONENT DESC: Anchor
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.