MAURY USCG vessel records Sign in
← All vessels

OKTEM AKSOY

OKTEM AKSOY is a 2003 freight ship. The Coast Guard has recorded 27 inspections since 2004, most recently in November 2022, along with 10 deficiencies and 7 operational controls.

Records from 2004 to 2022. Most recent: operational control imposed, 9 November 2022.

Built
2003
Last inspected
9 November 2022
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9282742 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9HA2015
666340
Flag
MALTA
—
Maury page id
psix-666340

Inspections, by type

…with no type recorded13
Years with a record 9 calendar years (2004–2022)
The 27 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it18207 - Convention (Subpart B), Net Ton
52441 - Dead Weight, Ton
60772 - Displacement, Ton
30058 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 27

9 November 2022 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7592390
17 March 2022 PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7413358
31 July 2017 Administrative Inspection
Administrative · USCG Arctic District (dp) · USCG Arctic District (CGD-A) · Activity 6288796
3 April 2017 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6116467
11 February 2016 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5813461
22 January 2016 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5802026
20 January 2016 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5800775
19 January 2016 Ballast Water Examination · ISPS III Exam · NPV Safety Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5799528
12 January 2016 COE-Administrative
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5796279
19 November 2010 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3889786
11 February 2010 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3679446
6 February 2010 In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3676360
19 January 2009 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 3396474
30 October 2007 Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3089194
19 September 2007 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3061285
14 September 2007 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3054899
14 September 2007 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3061966
23 April 2007 ISPS II Exam · Ballast Water Examination · NPV Safety Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2913581
23 February 2006 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2590651
21 February 2006 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2588810
24 October 2005 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2520830
24 October 2005 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2520861
23 October 2005 ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2520512
1 August 2004 ISPS II Exam
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2151852
28 January 2004 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1995517
27 January 2004 Type not recorded
No type recorded · USCGC STINGRAY (WPB 87305) · USCG Heartland District (CGD-H) · Activity 1995449
23 January 2004 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1991326

Deficiency record · 10

Electrical › Electric Supply System (service) › Cable
Issued 19 January 2016 Resolved
VSL EXPERIENCED A MARINE CASUALTY ON 17JAN16 WHEN 2ND ENGINEER EXPERIENCED SECOND AND THIRD DEGREE ELECTRICAL BURNS FROM THE NO. 1 CRANE BUCKET.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 January 2016
Resolved 19 January 2016
Resolution: CABLE CONNECTOR REPLACED AND APPROVED BY CLASS
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 19 January 2016 Resolved
PROTECTIVE CABLE LOCATED AT THE TURN OF THE PORT NO.1 CARGO TANK STARBOARD CORNER WAS MISSING, ELECTRICAL CABLE EXPOSED WAS WRAPPED WITH TAPE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 February 2016
Resolved 19 January 2016
Resolution: CLASS SOCIETY (NKK) OBSERVED DEFICIENCY IN QUESTION AND APPROVED CURRENT PROTECTION OF CABLE.
Operations/Management › Pollution › Control of Discharge of Oil
Issued 19 January 2016 Resolved
PSCO OBSERVED SEVEN 55 GALLON DRUMS OF HYDRAULIC OIL STORED IN THE FORWARD BOSUN STORES, FORWARD OF THE COLLISION BULKHEAD.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 2 February 2016
Resolved 19 January 2016
Resolution: CLASS HAD SHIP MOVE DRUMS TO AFT STEERING.
Navigation › Collision/Grounding Avoidance › Radar
Issued 6 February 2010 Resolved
Vessel reported its X-band radar is inoperable. Must provide class or tech report prior to departure from port. 33 CFR 164.35(a)
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 12 February 2010
Resolved 26 February 2010
Resolution: Received tech report; X-band radar was repaired and is operable.
Construction/Loadline › Markings › Load Line Assigning Authority Mark
Issued 19 September 2007 Resolved
Current L.L. markings indicate NKK class and do not reflect current B.V. class
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 30 November 2007
Resolution: Cleared via fax from Class Society after class survey was conducted on 21 September 07
Construction/Loadline › Markings › Load Line Mark
Issued 19 September 2007 Resolved
L.L. markings not painted in contrasting colors 66 1/8
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 30 November 2007
Resolution: Cleared via fax from Class Society after class survey was conducted on 21 September 07
Lifesaving › Lifeboat › Markings
Issued 19 September 2007 Resolved
Retro Refective Tape was worn and non reflective. Corrected on site
Condition: Improper/Lack of Maintenance
Due 19 September 2007
Resolved 19 September 2007
Resolution: Cleared on site
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 19 September 2007 Resolved
Portside top railing adjacent to #1 hatch cover was fractured at weld and seperated from stanchion
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 September 2007
Resolved 30 November 2007
Resolution: Cleared via fax from Class Society after class survey was conducted on 21 September 07.
Engineering › Steering Gear System › Ram
Issued 21 February 2006 Resolved
Vessels steering gear jumps back and forth and will not stop when rudder is directed from 10 degrees and below to port. Psc team tested both pumps with same result.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 February 2006
Resolved 23 February 2006
Resolution: Recieved class report attesting to repair and recalibration of steering gear.
Navigation › Piloting/Steering › Gyro Compass
Issued 24 October 2005 Resolved
On Oct. 23, 2005 the Pilots Association notified the COTP that the M/V Nord Ocean had an inoperable gyrocompass. On 24 Oct 2005 Sector Delaware Bay issued LOD 51-05 to M/V Nord Ocean for one inbound transit of the Delaware River & Bay. The vessel is in violation of 33CFR164.53(b)
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 31 October 2005
Resolved 26 October 2005
Resolution: On October 26, 2005 Sector Delaware Bay received the technician report that the gyrocompass was tested and operating to the satisfaction of the repair tech.

Ownership record