MAURY USCG vessel records Sign in
← All vessels

MARINER

MARINER is a freight ship. The Coast Guard has recorded 1 inspection in 2004, along with 15 deficiencies — 2 with no resolution recorded —.

Records in 2004. Most recent: inspection, 13 January 2004.

Built
Not recorded
Last inspected
13 January 2004
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7927843 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
J8B2919
666362
Flag
SAINT VINCENT AND THE GRENADINES
—
Maury page id
psix-666362

Inspections, by type

…past their stated due date2
Years with a record 1 calendar year (2004)
The 1 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 22 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it13105 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.

Inspection history · 1

13 January 2004 Annual Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1983065

Deficiency record · 15

Personnel › Certificates/Documents/Licenses
Issued 13 January 2004 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Due 20 February 2004
Resolved 24 February 2004
Resolution: Proper documentation was supplied.
Personnel › Certificates/Documents/Licenses
Issued 13 January 2004 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Due 20 February 2004
Resolved 24 February 2004
Resolution: Proper documentation was supplied.
Navigation › Piloting/Steering
Issued 13 January 2004 Resolved
Vessel does not have maneuvering facts sheet displayed on bridge. Displayed maneuvering facts sheet IAW 33CFR 164.35(G). LEGACY COMPONENT DESC: Maneuvering Information Fact Sheet
Action required: 15 - Rectify deficiencies by next port
Due 21 March 2004
Resolved 24 February 2004
Resolution: Manuevering facts sheet was displayed on bridge.
Electrical › Electric Supply System (service)
Issued 13 January 2004 Resolved
Batteries in Emergency Generator space were not properly stowed. Properly stow batteries IAW Solas 74 unamended CH II-1 REG 23(a)(ii) to the satisfaction of Certificate Issuing Authority.
Action required: 15 - Rectify deficiencies by next port
Due 21 March 2004
Resolved 24 February 2004
Resolution: Batteries were properly stowed.
Electrical › Electrical Distribution System (service)
Issued 13 January 2004 Resolved
Numerous electrical boxes in machinery spaces need covers. Cover electical boxes IAW Solas 74 unamended CH II-1 Reg 27 to the satisfaction of Certificate Issuing Authority LEGACY COMPONENT DESC: Junction Box
Action required: 17 - Rectify deficiencies prior to departure
Due 20 February 2004
Resolved 24 February 2004
Resolution: Electrical boxes had proper covers installed.
Fire Fighting › Miscellaneous Items
Issued 13 January 2004 Resolved
Numerous portable fire extinguishers are missing in machinery spaces. Install portable fire extinguishers in machinery spaces IAW Solas 74 unamended CH II-2 Reg 15 to the satisfaction of Certificate Issuing Authority.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 February 2004
Resolved 24 February 2004
Resolution: Fire control plan was updated to reflect new number of portable fire extinguishers, and was approved by Certificate Issuing Authority.
Documentation › Safety/Response Plans/Programs
Issued 13 January 2004 Resolved
Provide up to date fire control plan to include deficiency 07 IAW Solas 74 unamended CH II-2 Reg 4 to the satisfaction of Certificate Issuing Authority. LEGACY COMPONENT DESC: Fire Control Plans
Action required: 17 - Rectify deficiencies prior to departure
Due 20 February 2004
Resolved 24 February 2004
Resolution: Fire Control Plan was updated to reflect changes to vessel and was approved by Certificate Issuing Authority.
Engineering › Diesel Engine (propulsion-electric)
Issued 13 January 2004 Resolved
Ship Service Diesel Generator #4 has excessive fuel/ oil leaks. Repair fuel/oil leaks IAW Solas 74 unamended CH II-2 Reg 33 to the satisfaction of Certificate Issuing Authority.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 February 2004
Resolved 24 February 2004
Resolution: Excessive fuel/oil leaks on generator #4 were repaired.
Engineering
Issued 13 January 2004 Resolved
Excessive Oil in bilges of machinery spaces Remove IAW Solas 74 unamended CH II-2 Reg 2.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 February 2004
Resolved 24 February 2004
Resolution: Excessive oil in bilges of machinery spaces was removed.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 13 January 2004 No resolution recorded
OWS inoperative. Repair OWS IAW MARPOL 74/78 Annex I Reg 16 to the satisfaction of Certificate Issuing Authority. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Action required: 15 - Rectify deficiencies by next port
Due 21 March 2004 — due date passed with no resolution recorded
Engineering › Steering Gear System
Issued 13 January 2004 Resolved
"T" wrench for emergency steering port side to be provided IAW Solas 74 unamended CH II-1 Reg 29. LEGACY COMPONENT DESC: Valve
Action required: 17 - Rectify deficiencies prior to departure
Due 20 February 2004
Resolved 24 February 2004
Resolution: "T" wrench for emergency steering port side was provided.
Fire Fighting › Fire Pumps › Arrangement
Issued 13 January 2004 Resolved
Emergency fire pump gauge inoperable/unreadable. Repair IAW Solas 74 unamended CH II-2 Reg 5(b)(2) to the satisfaction of Certificate Issuing Authority.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 21 March 2004
Resolved 27 May 2007
Resolution: Vessel is considered out of service (DEAD) as per EQUASIS. -[name withheld]
Lifesaving › Rescue Boat Equipment
Issued 13 January 2004 Resolved
Oar in Stbd life boat was broken. Replace oars as needed in Port/Starboard life boats IAW LSA CODE CH 5 reg 5.1.2.1 to the satisfaction of Certificate Issuing Authority. LEGACY COMPONENT DESC: Paddle/Oar
Action required: 17 - Rectify deficiencies prior to departure
Due 20 February 2004
Resolved 24 February 2004
Resolution: New oars were provided for life boats.
Construction/Loadline › Structures › Door
Issued 13 January 2004 No resolution recorded
Water-Tight-Door #07 is inoperable in local control. Repair to the satisfaction of certificate issuing authority IAW with ICLL 66 Annex 1 Reg 17(1).
Action required: 17 - Rectify deficiencies prior to departure
Due 24 February 2004 — due date passed with no resolution recorded
Documentation › Logs/Records › Garbage Recordkeeping
Issued 13 January 2004 Resolved
Vessel does not have a Garbage Record book. Start Garbage Record book IAW MARPOL 73/78 Annex V to the satisfaction of certificate issuing authority.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 February 2004
Resolved 20 February 2004
Resolution: Garbage Record book was started. Vessel was laid up for 5 years with shore based garbage service provided.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.