OBSERVER

OBSERVER is a 1949 passenger vessel (inspected). The Coast Guard has recorded 62 inspections since 1988, most recently in December 2025, along with 104 deficiencies and 1 casualty investigation in 2022.

Records from 1988 to 2025. Most recent: inspection, 19 December 2025.

Built
1949
Last inspected
19 December 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC5191
Flag
UNITED STATES
367037280
Maury page id
psix-66637

Inspections, by type

…with no type recorded7
Years with a record 32 calendar years (1988–2025)
The 62 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)97.7 ft × 25.1 ft × 7.5 ft
Registered tonnagegross 96 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNASHVILLE BRIDGE COMPANY · NASHVILLE, TN, UNITED STATES · built 1949
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portWILMINGTON, DE
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 11 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it96 - Regulatory (Subpart C or D), Gross Ton
65 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDC5191MMSI 367037280 · active · compulsorily equipped · granted 15 March 2025, expires 27 April 2035
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 62

19 December 2025 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8285713
14 December 2024 Administrative Inspection · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8047389
29 November 2023 Administrative Inspection · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7831340
1 May 2023 In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7678951
19 October 2022 COI Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7580409
1 September 2022 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7548773
23 August 2022 Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7541939
4 August 2022 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7629550
15 July 2022 Drydock Exam · In-Service Inspection · Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7507753
24 February 2022 Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7401165
11 February 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7139540
3 December 2019 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6866253
28 November 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6588288
7 December 2017 Administrative Inspection · COI Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6320540
10 July 2017 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6188133
12 December 2016 Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6056656
14 December 2015 Deficiency Check · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5781286
2 December 2011 Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4199985
22 November 2010 Periodic Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3901363
26 January 2010 Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3670621
18 March 2009 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3435422
28 January 2009 MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3401887
11 December 2007 Deficiency Check · COI Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3112877
19 March 2007 Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2891057
18 October 2006 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2803244
6 June 2006 Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2671636
28 June 2005 Hull Examination · Internal Structural Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2406222
7 December 2004 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2255060
24 November 2004 Periodic Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2247308
12 December 2002 Administrative Inspection · COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1717087
6 December 2001 Re-Inspection · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1412379
29 June 2001 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 291691
26 March 2000 Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1050072
28 January 2000 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1468105
30 November 1999 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 810872
1 November 1999 COI Inspection · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1393274
28 December 1998 Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 809412
29 October 1998 Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1466576
30 December 1997 Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1450114
3 November 1997 Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1447774
4 December 1996 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1434487
4 November 1996 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1449976
4 July 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1086940
13 February 1996 Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 880235
26 April 1995 COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 863391
26 April 1994 COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1167641
24 February 1994 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1382727
1 July 1993 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1156935
3 May 1993 COI Inspection · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1142036
23 March 1992 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1261210
2 April 1991 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 913610
6 September 1990 Excursion Permit
Administrative · MSO Paducah · USCG Heartland District (CGD-H) · Activity 912924
30 April 1990 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1236423
23 April 1990 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 904918
26 May 1989 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1276684
24 April 1989 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 895807
16 September 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1350294
1 August 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1342599
15 July 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1036533
6 June 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 887852
12 May 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1348950
11 May 1988 Hull Examination · Initial Certification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1318030

Deficiency record · 104

10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 December 2025 Resolved
All vessel must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Stern light inoperable. Repair prior to operation at night.
Action required: 705 - Other - as specified
Resolved 27 January 2026
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 19 December 2025 Resolved
Each watertight bulkhead must be of sufficient strength to be capable of remaining watertight with a head of water to the top of the bulkhead. Engine room lower forward bulkhead holed/wasted, gauge lower 6” of entire bulkhead, provide results of gauging and repair as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 January 2026
Resolved 27 January 2026
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 19 December 2025 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Child life jacket donning instructions not posted.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 January 2026
Resolved 27 January 2026
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 19 December 2025 Resolved
Vessel must comply with the structural requirements of ABS Steel Vessel Rules (<61 Meters). Engine room forward entrance corner holed/wasted with temporary epoxy repairs, permanent repairs required.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 January 2026
Resolved 27 January 2026
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 19 December 2025 Resolved
A weathertight door must be provided for each opening located in a deck house or companionway. Weathertight forward door on 2nd deck will not close completely due to deformation of door.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 January 2026
Resolved 27 January 2026
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 December 2025 Resolved
For each alternating current generator, a means for measuring frequency must also be provided. Starboard generator frequency meter inoperable
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 January 2026
Resolved 27 January 2026
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 19 December 2025 Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from all passenger and crew accommodation spaces located below the main deck. Additional emergency lights for egress required IVO of door in 2nd deck bar area and forward emergency exit door on 2nd deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 January 2026
Resolved 27 January 2026
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 December 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons. Remove dead end wiring found below wheelhouse.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 January 2026
Resolved 27 January 2026
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 4 December 2023 Resolved
The intent of this part is to insure that the scantling's, material, fastenings, workmanship and arrangement of each vessel are such as to provide for safe operation in accordance with the terms of its certificate of inspection. Marine Inspector identified an apprx 8" x 10" hole on the aft second deck bulkhead behind the receptacle box. Crop and renew to the satisfaction of a Coast Guard Marine Inspector. 46 CFR 177.05-1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 January 2024
Resolved 12 January 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 December 2023 Resolved
The intent of this part is to insure that the main propulsion machinery installed on each vessel is suitable for the vessel and its operation and that the auxiliary machinery is suitable for the purpose intended. It is further intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery fail lire and personnel injury. Marine Inspector discovered a leak in the starboard aft rudder seal. Repair/renew to the satisfaction of a Coast Guard Marine Inspector. 46 CFR 182.01-5
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 December 2023
Resolved 2 January 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 December 2023 Resolved
Junction boxes, connection boxes, and outlet boxes, for use in damp or wet locations shall be of watertight construction. Marine Inspector discovered receptacle box on upper deck missing closure device. Repair/renew closure device to the satisfaction of a Coast Guard Marine Inspector. 46 CFR 183.10-20(k)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 January 2024
Resolved 12 January 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 December 2023 Resolved
Equipment mounted on a hinged door of an enclosure shall be constructed or shielded in such a manner that no live parts of the door mounted equipment will be exposed to accidental contact by a person with the door open and the circuit energized. Marine Inspector discovered breaker box on bridge with an empty circuit breaker holder. Provide a blank cover to protect from exposure. 46 CFR 183.10-10(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 December 2023
Resolved 12 January 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 October 2022 Resolved
Electrical equipment and installations must be suitable for the roll, pitch, and vibration of the vessel underway. Electrical equipment used in machinery spaces must be dripproof. Multiple emergency light power supplies installed as directly plugged into outlets. Provide hardwired installations for emergency lights. 46 CFR 183.210(a)(1) 46 CFR 183.220(a) 50C
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 November 2022
Resolved 14 December 2022
Resolution: Light fixtures installed correctly.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 October 2022 Resolved
The master or person in charge of a ship to which this section applies shall ensure that the ship is not operated unless a garbage management plan meeting 33 CFR 151.57 (b) is on the ship and that each person handling garbage follows the plan. Garbage management plan not on board. Provide Garbage Management plan. 33 CFR 151.57 50C
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 November 2022
Resolved 4 November 2022
Resolution: Garbage/Waste management plan on board. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 October 2022 Resolved
Protection of non-metallic piping materials from mechanical damage shall be specifically considered. Hose for bilge pump in steering department chaffing due to wasted hose bracket. Repair or provide new hose bracket and arrange to prevent chaffing. 46 CFR 182.720(d)(2) 50C
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 November 2022
Resolved 4 November 2022
Resolution: Hose replaced. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 20 October 2022 Resolved
Each floating waterlight must be approved in accordance with 46 CFR 161.010 in subchapter Q. Batteries in floating waterlight not the required type per manufacture. Replace with correct battery type. 46 CFR 180.70(d) 50C
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 November 2022
Resolved 4 November 2022
Resolution: Batteries replaced with authorized type. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 20 October 2022 Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking. Upper deck passenger count does not match posted stability letter. Post correct number as per current stability letter. 46 CFR 185.602(g) 50C
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 November 2022
Resolved 4 November 2022
Resolution: Correct passenger count posted on board. All sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 20 October 2022 Resolved
Vessels shall be inspected for compliance with the standards...Examine and test by operation all watertight closures in the hull, decks and bulkheads. Missing gasket on forward watertight door. Install new gasket to watertight door. 46 CFR 176.25 50C
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 November 2022
Resolved 14 December 2022
Resolution: New gasket installed.
04 - Emergency Systems › N/A - No Subsystem › Safe areas
Issued 20 October 2022 Resolved
All passengers to be provided a copy of the emergency egress plan for the vessel. No posted emergency egress plans in staterooms. Post emergency egress plans for passengers to see. 46 CFR 3306(n) 50C
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 November 2022
Resolved 7 June 2023
Resolution: Posted escape plans.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 20 October 2022 Resolved
All escape hatches and other emergency exits shall be marked. Emergency exits not marked. Post emergency exit signs on all emergency exits. 46 CFR 185.30-15 50C
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 November 2022
Resolved 14 December 2022
Resolution: Emergency signage posted.
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 20 October 2022 Resolved
All vessels shall be provided with not less than two avenues of escape from all general areas accessible to the passengers. One escape door found locked in between staterooms. Unlock escape door and keep unlocked at all times. 46 CFR 177.15-1 50C
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 November 2022
Resolved 14 December 2022
Resolution: Escape door repaired and working properly.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 19 October 2022 Resolved
All portions of machinery space bulkheads must be watertight below the bulkhead deck. Wasted watertight bulkhead in forward engine room to sea chest compartment IVO potable water tank. Provide repair plan and conduct repairs to the satisfaction of attending marine inspector. 46 CFR 171.095(a) 50C
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 November 2022
Resolved 4 November 2022
Resolution: Blkhd section cropped and renewed. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 October 2022 Resolved
All electrical equipment and circuits must be clearly marked and identified. Steering control box labeling painted over. Forward most box cover upper portion detached. Provide labeling indicating function of box and push buttons, repair detached cover. 46 CFR 183.220(d) 50C
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 November 2022
Resolved 4 November 2022
Resolution: Steering Gear electrical boxes labeled. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 February 2022 Resolved
The bilge piping piercing the collision bulkhead shall be fitted with a screw-down valve located on the forward side of the collision bulkhead and operable from above the weather deck. MI discovered weather deck fore-peak bilge suction screw down valve seized and inoperable. Repair or replace weather deck fore-peak bilge suction screw down valve to the satisfaction of a Coast Guard Marine Inspector. 46 CFR 182.25-5(d) 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2022
Resolved 7 March 2022
Resolution: Bilge piping had previously been cropped out and plugged. Vessel has portable pump on board to meet regulation.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 24 February 2022 Resolved
The minimum capacity of the power fire pump shall be 50 gal per minute at a pressure of not less than 60 psi at the pump outlet. MI observed power fire pump pressure of 42 psi during operational test. Repair or replace equipment or machinery necessary to meet pump outlet pressure of 60 psi. 46 CFR 181.10-1(c) 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2022
Resolved 10 March 2022
Resolution: Replaced pressure gauge. Test Sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 February 2022 Resolved
One length of fire hose shall be provided for each fire hydrant required. The fire hose must be lined commercial fire hose that conforms to Underwriters Laboratories Inc. MI inspector observed water leaking through the fire hose located on the first deck, during the fire pump test. Replace damaged fire hose with new and operable fire hose. 46 CFR 181.15-10(a)(d)(1) 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2022
Resolved 10 March 2022
Resolution: Vessel replaced all fire hoses on deck. Test Sat.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 24 February 2022 Resolved
A vessel on a Lakes, Bays, and Sounds or Rivers route must carry three hand red flare distress signals and three hand orange smoke distress signals. MI discovered 06 hand red flare distress signals on board that are expired. Obtain correct amount and type of flare distress signals. 46 CFR 180.68(a)(1)(2) 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2022
Resolved 10 March 2022
Resolution: Vessel obtained new red and orange flares. All Sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 February 2022 Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018. MI discovered child size lifejackets retrreflective tape warn to the point that it does not reflect as designed. Replace retroreflective tape on all child size life jackets. 46 CFR 185.604(h) 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2022
Resolved 29 March 2022
Resolution: New child size life jackets received onboard with new retroreflective tape.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 February 2022 Resolved
Each ring life buoy must be marked with type two retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. MI discovered retroreflective tape on all ring buoys on board do not properly reflect light as designed. Replace retroreflective tape on all ring buoy's on board vessel. 46 CFR 185.604(i) 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2022
Resolved 10 March 2022
Resolution: New retroreflective tape installed on ring bouy's. All Sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 February 2022 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. MI discovered incorrect numbering of life jacket stowage compartment relating to number of jackets actually stowed in that compartment. Stowe correct amount of life jackets in stowage cabinet to correspond to numbering system of life jacket stowage cabinet. 46 CFR 185.604(f) 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2022
Resolved 10 March 2022
Resolution: Correct number of life jackets stowed in locker. All sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 February 2022 Resolved
The Bridge-to-Bridge radiotelephone station will be inspected on vessels subject to regular inspections pursuant to the requirements of Parts II and III of Title II of the Communications Act. Vessel does not have current Bridge-to-Bridge radiotelephone certificate. Obtain current Bridge-to-Bridge radiotelephone certificate on board vessel. 46 CFR 184.25-1 47 CFR 80.1005 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2022
Resolved 10 March 2022
Resolution: Vessel obtained Bridge-to-Bridge radio certificate. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 February 2022 Resolved
Switchboards shall be fitted with driphoods and non-conducting hand rails. Non-conducting mats or grating shall be provided on deck in front and rear of switchboard. MI observed engine room switchboard did not have driphood attached nor non-conductive matting in front of the switchboard. Install driphood to the top of the switchboard and place non-conducting mat in front of switchboard. 46 CFR 183.10-15(b) 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2022
Resolved 10 March 2022
Resolution: Vessel installed driphood over switchboard. All Sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 24 February 2022 Resolved
Each hatch cover on board must be attached to the hatch frame or coaming by hinges, captive chains, or other device to prevent its loss. MI discovered both forepeak hatches did not have captive chains connected to hatch frame or coamings. Attach hatch covers to hatch frame or coaming. 46 CFR 171.124(b)(2) 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2022
Resolved 10 March 2022
Resolution: Forepeak hatch covers have chains attached to frame. All Sat.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 24 February 2022 Resolved
All machinery is to be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure, and personnel injury. MI discovered protective machinery guards on port main engine were broken and not covering dangerous rotating machinery. Repair or replace machinery guards on port main engine. 46 CFR 182.01-5 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2022
Resolved 10 March 2022
Resolution: Machinery guards have been repaired. All Sat.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 24 February 2022 Resolved
A vessel must carry either a first aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. MI discovered un-approved first-aid kit on board vessel that does not contain required contents. Obtain and place on board approved type first aid kit or contents equivalent to required regulation. 46 CFR 184.710 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2022
Resolved 10 March 2022
Resolution: Vessel obtained correct CG approved first aid kit. All Sat.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 24 February 2022 Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel. MI discovered generic emergency broadcast placard posted on bridge with no vessel specific information. Add vessel specific information to posted emergency broadcast placard. 46 CFR 184.506 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2022
Resolved 10 March 2022
Resolution: Vessel updated emergency broadcast placard with vessel specific identification. All Sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 February 2022 Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria the maximum number of passengers allowed on an upper deck must be indicated at the entranceway to that deck. MI observed the outside first deck ladder-well did not have posted placard for number of passengers allowed. Post placard with max number of passengers allowed. 46 CFR 185.602(g) 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2022
Resolved 10 March 2022
Resolution: Vessel posted placard for max allowable pax for uper deck. All Sat.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 11 February 2021 Resolved
Class 1 watertight doors are permitted within working spaces where ever located if the door is in a location where it will be closed at all times except when in use. 03 WTD below the bulkhead deck do not seal properly and must be adjusted. 46 CFR 170.255(b)(1)
Action required: 17 - Rectify deficiencies prior to departure
Due 12 February 2021
Resolved 26 March 2021
Resolution: MIs witnessed satisfactory operation.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 11 February 2021 Resolved
A vessel must carry a first aid kit approved under 46 CFR 160.041 or equivalent. The first aid kit onboard was expired. 46 CFR 184.710
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 March 2021
Resolution: MIs witnessed satisfactory operation.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 11 February 2021 Resolved
The master shall conduct drills as necessary to ensure that all crew members are familiar with their duties. Provide the entire complement of crew as per the COI, in order to conduct drills and underway tests. 46 CFR 185.25-10
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 March 2021
Resolution: MIs witnessed satisfactory MOB drill.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 11 February 2021 Resolved
An indicator light for each door which warns when the door is open must be installed on the bridge. One of the WTD indicators on the wheelhouse was inoperable. 46 CFR 170.255(e)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 March 2021
Resolution: MIs witnessed satisfactory operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 February 2021 Resolved
The bilge suctions shall be fitted with strainers. The bilge suction point in the rudder room was missing a strainer. 46 CFR 182.25-5(b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 March 2021
Resolution: MIs witnessed satisfactory installation.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 11 February 2021 Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation. An FCC licensed technician will issue a Safety Radio Telephony Certificate if the radio installation passes the inspection. Provide a Safety Radio Telephony Certificate prior to operating greater than 1000 feet from shore. 47 CFR 80.903
Action required: 705 - Other - as specified
Due 12 February 2021
Resolved 26 March 2021
Resolution: MIs reviewed satisfactory radio telephony permit.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 5 December 2019 Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment. Vessel could not prove its bilge system was operation in all locations as required.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 December 2019
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 5 December 2019 Resolved
All escape hatched and other emergency exits shall be marked on both sides using at least 1 inch letters: "Emergency Exit Keep Clear." Vessel's Emergency Exits are not clearly marked on doors as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 December 2019
Resolution: Vessel has posted "Emergency Exit"signs adjacent to berthing.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 5 December 2019 Resolved
Penetrations and openings in watertight bulkheads must have a means to make them watertight. The watertight doors in the engine room did not close to watertight as per the stability letter.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 December 2019
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 5 December 2019 Resolved
Each launching appliance and each survival craft and rescue boat on a vessel must be in good working order and ready for immediate use before the vessel leaves port and at all times when the vessel is underway. Vessels rescue boat's launching appliance was inoperable affecting the operational readiness of the equipment.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 December 2019
Resolution: The rescue boat launching appliance was operational and the crew conducted a man overboard recovery drill successfully.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 5 December 2019 Resolved
Portable watertight containers for distress flares and smoke signals shall be of a bright color, portable water tight container, and containers shall be clearly marked "Distress Signals." Container for the distress signals was not watertight and marked IAW federal law and regulation.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 December 2019
Resolution: Distress signals were in the requiered contianer and labeled.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 5 December 2019 Resolved
Vessel is required to have on board the documents listed in table 47CFR80.401. Vessels did not have on board the FCC Safety certificate as required by FCC table 47CFR80.401.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 December 2019
Resolution: A current FCC safety radio certificate was onboard the vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 December 2019 Resolved
Chart and nautical publications appropriate for the intended voyage and up-to-date must be on board. Master was unable to provide charts and publications for intended routes.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 December 2019
Resolution: Vessel had current charts and publicaitons onboard via internet which the company utilizes for all thier vessels. Vessel had backup charts and publicaitons on the thunmb drive which was satisfactory.
Operations/Management › Drills/Instruction › Launching/Recovery of Survival Craft
Issued 7 December 2017 Resolved
Vessel crew has not trained to safely lower and operate the rescue boat required by the COI.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 December 2017
Resolved 13 December 2017
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 7 December 2017 Resolved
Vessel does not have written emergency procedures.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 December 2017
Resolved 13 December 2017
Personnel › Training › Familiarization Training
Issued 7 December 2017 Resolved
Vessel does not have any log entries proving completion of safety training/drills.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 December 2017
Resolved 13 December 2017
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 14 December 2015 Resolved
Relocate emergency fuel shut off valve outside of the fuel tank space.
Condition: Improper Installation
Due 24 December 2015
Resolved 21 December 2015
Engineering › Bilge Water Management System › Not Operational
Issued 14 December 2015 Resolved
Bilge alarms not operational.
Condition: Improper/Lack of Maintenance
Due 24 December 2015
Resolved 21 December 2015
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 November 2010 Resolved
Navigation lights to be on a backup batterey systyem.
Condition: Improper Installation
Due 30 November 2010
Resolved 30 November 2010
Fire Fighting › Fire Pumps › Arrangement
Issued 26 January 2010 Resolved
Provide a pressure gauge on the fire pump.
Action required: 705 - Other - as specified
Due 26 February 2010
Resolved 30 April 2010
Resolution: Item corrected.
Engineering › Bilge Water Management System › Interface Detector
Issued 26 January 2010 Resolved
Prove proper operation of the bilge alarm in the generator compartment.
Action required: 705 - Other - as specified
Due 26 February 2010
Resolved 30 April 2010
Resolution: Item corrected.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 26 January 2010 Resolved
Provide an up to date navigational chart of the Houston Ship Channel.
Action required: 705 - Other - as specified
Due 26 February 2010
Resolved 30 April 2010
Resolution: Item corrected.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 28 January 2009 Resolved
Provide updated versions of Tide Tables, Tide Current Tables and Coast Pilots.
Action required: 705 - Other - as specified
Due 28 February 2009
Resolved 17 March 2009
Resolution: Observed, cleared def.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 28 January 2009 Resolved
Make permanent repairs to the hole in the MSD.
Action required: 705 - Other - as specified
Due 28 February 2009
Resolved 17 March 2009
Resolution: Observed repair, cleared def.
Engineering › Bilge Water Management System › Pump
Issued 28 January 2009 Resolved
Repair and prove proper operation of the Bilge pump in the shaft ally space.
Action required: 705 - Other - as specified
Due 28 February 2009
Resolved 17 March 2009
Resolution: Observed repair, cleared def.
Stability › Watertight Integrity › General
Issued 28 January 2009 Resolved
Repair the hole in the overhead and the hole in the aft bulkhead of the machinery space.
Action required: 705 - Other - as specified
Due 28 February 2009
Resolved 17 March 2009
Resolution: Observed repair, cleared def.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 11 December 2007 Resolved
Repair the alarm panel and prove proper operation of all Bilge alarms.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 January 2008
Resolved 2 January 2008
Resolution: Alarm panel repaired.
Fire Fighting › Fire Main › Condition
Issued 11 December 2007 Resolved
Replace the piping connection for the fire hose on the forward hose station.
Action required: 705 - Other - as specified
Due 11 January 2008
Resolved 2 January 2008
Resolution: Fire Station repaired.
Stability › Watertight Integrity › General
Issued 11 December 2007 Resolved
Remove the excessive paint and provide routine servicing to the three watertight doors.
Action required: 705 - Other - as specified
Due 11 January 2008
Resolved 2 January 2008
Resolution: Item repaired.
Navigation › Piloting/Steering › Magnetic Compass
Issued 11 December 2007 Resolved
Replace the missing magnetic compass.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 January 2008
Resolved 2 January 2008
Resolution: magnetic compass installed.
Lifesaving › Lifebuoys › Serviceable
Issued 11 December 2007 Resolved
Replace the lifebuoy at the aft station.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 January 2008
Resolved 2 January 2008
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 11 December 2007 Resolved
Repair the 2 inoperable smoke detectors on the upper deck passenger cabin.
Action required: 705 - Other - as specified
Due 11 January 2008
Resolved 2 January 2008
Resolution: Repairs complete.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 11 December 2007 Resolved
Provide a method to lock the sewage tank overboard discharge valve.
Action required: 705 - Other - as specified
Due 11 January 2008
Resolved 2 January 2008
Resolution: overboard discharge valve locked.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 11 December 2007 Resolved
Provide a cover for the electrical junction box in the engine room overhead.
Action required: 705 - Other - as specified
Due 11 January 2008
Resolved 2 January 2008
Resolution: item repaired
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 11 December 2007 Resolved
Install Sea Rails and Grab Rails on the newely installed cook top.
Action required: 705 - Other - as specified
Due 11 January 2008
Resolved 2 January 2008
Resolution: Items installed.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 11 December 2007 Resolved
Install emergency lighting in the Galley and replace the battries on two emergency lighting systems on the upper deck.
Action required: 705 - Other - as specified
Due 11 January 2008
Resolved 2 January 2008
Resolution: Emergency lighting installed.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 December 2007 Resolved
Replace expired items in the first aid kit.
Action required: 705 - Other - as specified
Due 11 January 2008
Resolved 2 January 2008
Resolution: New 1st Aid Kit onboard.
Fire Fighting › Fire Pumps › Power Source
Issued 19 March 2007 Resolved
Repair fire pump's on/off switch.
Due 19 April 2007
Resolved 18 April 2007
Resolution: Item repaired.
Fire Fighting › Fire Pumps › Pressure
Issued 19 March 2007 Resolved
Install pressure gauge on fire pump.
Due 19 April 2007
Resolved 18 April 2007
Resolution: Item repaired.
Construction/Loadline › Hull › Hull Plating
Issued 19 March 2007 Resolved
Repair holes in female head's deck.
Due 19 April 2007
Resolved 18 April 2007
Resolution: Item repaired.
Personnel › Training › First Aid/CPR
Issued 19 March 2007 Resolved
Provide CPR certification certificate.
Due 19 April 2007
Resolved 18 April 2007
Resolution: Item repaired.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 19 March 2007 Resolved
Repair holes in fwd and aft engine room bulkheads.
Due 19 April 2007
Resolved 18 April 2007
Resolution: Item repaired.
Construction/Loadline › Structures › Machinery Space Opening
Issued 19 March 2007 Resolved
Remove hose going through aft watertight door in engine room.
Due 19 April 2007
Resolved 18 April 2007
Documentation › Certificates/Documents › Stability Letter
Issued 6 June 2006 Resolved
Find and post stability letter.
Due 6 July 2006
Resolved 30 June 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 6 June 2006 Resolved
Remove light fixture in aft compartment.
Due 6 July 2006
Resolved 30 June 2006
Engineering › Bilge Water Management System › Interface Detector
Issued 6 June 2006 Resolved
Mount bilge alarm in aft compartment.
Due 7 July 2006
Resolved 30 June 2006
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 6 June 2006 Resolved
Vessel may carry only 132 adults until replacement of 23 rejected lifejackets.
Due 6 July 2006
Resolved 30 June 2006
Lifesaving › Emergency Outfit › Fire ax
Issued 6 June 2006 Resolved
Place name of vessel on fire axes.
Due 7 July 2006
Resolved 30 June 2006
Stability › Watertight Integrity › General
Issued 6 June 2006 Resolved
Plug cable way holes in WTB aft compartment.
Due 7 July 2006
Resolved 30 June 2006
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 24 November 2004 Resolved
Life jacket storage box improperly stowed. Remove gear and properly stow jackets.
Action required: 705 - Other - as specified
Due 22 December 2004
Resolved 7 July 2005
Accommodation/Occupational Safety › Heating › Burners
Issued 24 November 2004 Resolved
Remove portable fat fryer from vessel.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 22 December 2004
Resolved 7 July 2005
Construction/Loadline › Penetrations › Gasket
Issued 24 November 2004 Resolved
Replace aft rudder compartment hatch gasket.
Action required: 705 - Other - as specified
Due 24 December 2004
Resolved 7 July 2005
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 24 November 2004 Resolved
Tighten all bolts on engine mounts.
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 December 2004
Resolved 7 July 2005
Electrical › Electrical Distribution System (service) › Cable
Issued 24 November 2004 Resolved
Remove all combustible material from the second deck electrical closet.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 December 2004
Resolved 7 July 2005
Engineering
Issued 1 November 1999 Resolved
RENEW REAR MAIN OIL SEAL ON PORT MAIN DIESEL ENGINE (46 CFR 182.05-1 ["OLD T"])
Condition: Unknown
Due 30 November 1999
Resolved 30 November 1999
Construction/Loadline
Issued 3 November 1997 Resolved
PROPERLY RENEW FORWARD DRAFTS MARKS. REQUIREMENT TO BE COMPLETED AT NEXT CREDIT HULL EXAMINATION TO THE SATISIFACTION OF THE ATTENDING U.S. CAOST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 3 November 1997
Resolved 3 November 1997
Fire Fighting
Issued 4 November 1996 Resolved
Conduct proper operational/pressure tests of the fire main using both fire pumps. Testing to be witnessed by a U.S. Coast Guard Marine Inspector.
Condition: Unknown
Due 4 November 1996
Resolved 4 November 1996
Lifesaving
Issued 4 November 1996 Resolved
Conduct proper emergency drills, to include man overboard, fire fighting and abandon ship drills. All drills to be witnessed by a U.S. Coast Guard Marine Inspector.
Condition: Unknown
Due 4 November 1996
Resolved 4 November 1996
Fire Fighting
Issued 4 November 1996 Resolved
Provide proper spanner wrenches for fire hose stations #2 and #4.
Condition: Unknown
Due 4 November 1996
Resolved 4 November 1996
Engineering
Issued 4 November 1996 Resolved
Provide vessel's Unfired Pressure Vessels (UPVs) for visual inspection.
Condition: Unknown
Due 4 November 1996
Resolved 4 November 1996
Documentation
Issued 4 November 1996 Resolved
Provide proper VHF radio Emergency Communications Placard.
Condition: Unknown
Due 4 November 1996
Resolved 4 November 1996
Electrical
Issued 11 May 1988 Resolved
PROVIDE COAST GUARD APPROVED PLANS FOR ELECTRICAL DISTRIBUTION PANELS. 46CFR177.05
Condition: Unknown
Due 11 May 1988
Resolved 11 May 1988
Construction/Loadline
Issued 11 May 1988 Resolved
PROVIDE COAST GUARD APPROVED PLANS FOR ALL STRUCTURES ABOVE MAIN DECK AS PER 46CFR177.05.
Condition: Unknown
Due 11 May 1988
Resolved 11 May 1988
Engineering
Issued 11 May 1988 Resolved
PROVIDE COAST GUARD APPROVAL FOR MAIN ENGINE AND GENERATOR GRID COOLERS AS PER MARINE SAFETY LTR M-70693 DTD 31 DEC 87. 46CFR177.O5
Condition: Unknown
Due 11 May 1988
Resolved 11 May 1988
Engineering
Issued 11 May 1988 Resolved
PROVIDE MANUFACTURER'S DATA REPORT (U-1A), PROFESSIONAL ENGINEERS CERT. (STATING PRESSURE VESSEL IS BUILT IAW APPLICABLE ASME CODE & 46CFR54) AND PRESSURE VESSEL PLANS & CALCULATIONS STAMPED BY PROFESSIONAL ENG., ALL THE ABOVE MUST SHOW EVIDENCE OF REVIEW BY USCG, FOR TWO AIR RECEIVERS ABOARD.
Condition: Unknown
Due 11 May 1988
Resolved 11 May 1988
Electrical
Issued 11 May 1988 Resolved
PROVIDE COAST GUARD APPROVED PLANS FOR ELECTRICAL WIRING SCHEMATIC FOR MAIN ENGINE AND GENERATOR ENGINE ALARM SYSTEM. 46CFR177.05
Condition: Unknown
Due 11 May 1988
Resolved 11 May 1988
Accommodation/Occupational Safety
Issued 11 May 1988 Resolved
PROVIDE COAST GUARD APPROVED PLANS FOR HEATING BOILER IN AUX. MACHINERY SPACE AND INCLUDED "HOT AND CHILL" WATER SYSTEM. 46CFR177.05
Condition: Unknown
Due 11 May 1988
Resolved 11 May 1988

Casualty record · 1

1 September 2022Routine · role: Involved in a Marine Casualty · activity 7548773
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.