11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 May 2026
Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required. Vessels life floats and ring buoy are missing the required brackets for waterlights.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2026
Resolved 26 June 2026
Resolution: Correct brackets installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 May 2026
Resolved
A vessel of more than 7.9 meters (26 feet) in length, but not more than 19.8 meters (65 feet), must carry a minimum of one life buoy of not less than 610 millimeters (24 inches) in diameter. Vessel 01 required life buoy needs to be replaced due to fading of approval number and wasted retro reflective tape.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2026
Resolved 26 June 2026
Resolution: Life ring replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 26 May 2026
Resolved
If the vessel carries more than one life float or buoyant apparatus in a group with each group secured by a single painter:Each life float and buoyant apparatus must be individually attached to the painter by a line meeting § 180.175(f)(3) (ii), (iii), and (iv) and long enough that each life float or buoyant apparatus can float without contacting any other life float or buoyant apparatus in the group. Vessel has two life floats not properly attached to the single painter/weak link.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2026
Resolved 28 May 2026
Resolution: Life floats properly attached to single painter.
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 26 May 2026
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:Charts of large enough scale to make safe navigation possible. Vessel operator could not prove when electronic charts were last updated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2026
Resolved 26 June 2026
Resolution: Electronic charts updated.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 5 May 2025
Resolved
Each survival craft required on a vessel by this part must meet one of the following:
For a life float—Approved under approval series 160.027 or other standard specified by the Commandant.
Life float did not have approval series 160.027.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2025
Resolved 3 June 2025
Resolution: old 25 persons life float and been replaced with two 12 persons life float.
02 - Structural Conditions › N/A - No Subsystem › Marking of IMO number
Issued 5 May 2025
Resolved
Each hull identification number must be carved, burned, stamped, embossed, molded, bonded, or otherwise permanently affixed to the boat so that alteration, removal, or replacement would be obvious. If the number is on a separate plate, the plate must be fastened in such a manner that its removal would normally cause some scarring of or damage to the surrounding hull area. A hull identification number must not be attached to parts of the boat that are removable.
Hull identification number was screwed in, removal would not cause scarring or damage to surrounding hull.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2025
Resolved 3 June 2025
Resolution: official number permanently attached to the vessel.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 May 2025
Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests:Monthly inspections required by NFPA 10 may be conducted
No logs of monthly extinguisher checks available.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 5 May 2025
Resolved 5 May 2025
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 5 May 2025
Resolved
The master of the vessel shall ensure that:(a) Each EPIRB, other than an EPIRB in an inflatable liferaft, must be tested monthly.... The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable.
No record of monthly EBIRP tests logged
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 5 May 2025
Resolved 10 May 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 16 July 2024
Resolved
Except as otherwise provided in this section, rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew. Equivalent protection may include lifelines, wire rope, chains, and bulwarks, which provide strength and support equivalent to fixed rails. Deck rails must include a top rail with the minimum height required by this section, and lower courses or equivalent protection as required by this section.
No lifelines on upper deck leadign to stairs. To satisfaction of Marine Inspector.
46 CFR 177.900
46 CFR
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 July 2024
Resolved 24 October 2024
Resolution: 03 chain life lines attached at second deck ladder, All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 July 2024
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets.
Child size life jackets were not labeled or seperated.
46 CFR 180.78
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 July 2024
Resolved 17 July 2024
Resolution: Lifejackets labeled correctly, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 16 July 2024
Resolved
Life floats. Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light
life float light didn't work
46 CFR 180.175.(d)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 July 2024
Resolved 17 July 2024
Resolution: Life float light replaced, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 June 2023
Resolved
46 CFR 182.530: Vessel of at least 7.9 meters (26 feet), a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces...(2) A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space.. Vessel is missing a high water alarm in compartment with steering gear. Aft bilge pump wiring is loose and causing a bad connection with intermitant alarm operations. Replace connections, and test to Marine Inspectors satisfaction.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2023
Resolved 26 June 2023
Resolution: Wiring was replaced and alarm tested sat.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 14 June 2023
Resolved
46 CFR 177.410(c)(4): ...Boundaries that separate machinery spaces from accommodation spaces, service spaces, and control spaces must be lined with noncombustible panels or insulation approved... Vessel had a penetration from machinery space to forward compartment. Seal penetration.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2023
Resolved 26 June 2023
Resolution: All blkhd penetrations were sealed, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 May 2023
Resolved
Vessel operator notified this office of main engine issues rendering the vessel inoperable at full capacity. Operator placed vessel out of service for repairs. If replacing engine, operator must provide new engine specifications to our office prior to installation. After proper repairs/replacement in kind of equipment, Coast Guard Marine Inspectors must witness satisfactory operation of main engine propulsion and control prior vessel going back into service of carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2023
Resolution: Operational, underway testing of the engine was conducted to the satisfaction of the attending MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 July 2022
Resolved
A vessel of at least 7.9 meters (26 feet) in length must be provided with individual bilge lines and bilge suction. The Space behind the collision bulkhead is missing it's bilge pump.
46 CFR 182.510(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 August 2022
Resolved 22 July 2022
Resolution: Belt guard installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 July 2022
Resolved
All machinery must be installed in such a manner as to afford adequate protection from personnel injury. The engines are each missing a cover for a belt.
46 CFR 182.100
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2022
Resolved 24 August 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 July 2022
Resolved
Child sized life jackets must be stowed in a location that appropriately marked and separate from adult life jackets. The child life jackets need to be separated from the adult ones.
46 CFR 180.78(a)(5)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2022
Resolved 2 August 2022
Resolution: Jackets seperated and labeled to prevent confusion
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 18 July 2022
Resolved
Boundaries which separate machinery spaces from accommodation spaces must be lined with noncombustible panels or insulation. Part of the engine room lagging was missing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2022
Resolved 2 August 2022
Resolution: Lagging installed to cover the missing section
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 11 May 2020
Resolved
A visiual and audible alarm must be provided at the operating station for high water level. 2 forward spaces need to have audible high water alarm.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 May 2020
Resolved 28 May 2020
Resolution: Master demonstrated proper operation
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 May 2020
Resolved
1 portable fire extinguisher rated 10-B:C required at operating station. Provide and mount a serviced fire extinguisher.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 May 2020
Resolved 28 May 2020
Resolution: Fire extinguisher serviced and mounted in operating station cabinet
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 11 May 2020
Resolved
Each vessel must have at least 2 operable portable battery lights, located at operating station and at access to propulsion machinery space. Vessel had 1 portable battery light at operating station.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 May 2020
Resolved 28 May 2020
Resolution: 2 portable battery lights onboard for follow up.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 May 2020
Resolved
Flex nonmetallic hose may be used in fuel oil, subject to the following requirements... fabricated with suitable material. Replace fuel hoses in engine room that are worn or dry rotted.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 May 2020
Resolved 28 May 2020
Resolution: Found all fuel hoses in engine room were replaced and in good condition.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 11 May 2020
Resolved
Each connection to a conductor or terminal part of a conductor must have a pressure type connector. Make a proper connection to oil sender on the port main.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 May 2020
Resolved 28 May 2020
Resolution: Permanent connection made for oil sender.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 11 May 2020
Resolved
Each watertight bulkhead must be capable of remaining watertight with a head of water to the top of the bulkhead. Seal bulkhead penetrations.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 May 2020
Resolved 28 May 2020
Resolution: Bulkhead penetrations foam sealed, sat.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 11 May 2020
Resolved
A vessel on a limited coastwise route must carry 6 hand red flare distress signals and 6 hand orange smoke signals; red hand flares can be substituted for orange smoke. provide 12 hand red flares total.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 May 2020
Resolved 28 May 2020
Resolution: 12 red hand flares onboard.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 11 May 2020
Resolved
Provide a suitable first aid kit, inventory sheet and instructions in accordance with 46 CFR 160.041-4.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 May 2020
Resolved 28 May 2020
Resolution: First aid kit provided
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 11 May 2020
Resolved
Produce original FCC Safety Radiotelephony Certificate available for inspection.
47 CFR 80
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2020
Resolved 28 May 2020
Resolution: Original certificate was provided.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 7 August 2018
Resolved
Prove proper operation of emergency fuel shutoff valves.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 August 2018
Resolved 13 August 2018
Resolution: Proved proper operation of fuel shutoff valves.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 August 2018
Resolved
Repair oil leak on port main engine turbo.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 August 2018
Resolved 13 August 2018
Resolution: Owner replaced port engine turbo.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 August 2018
Resolved
Repair water leak on STBD main engine IWO turbo.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 August 2018
Resolved 13 August 2018
Resolution: Owner has repaired water leak.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 7 August 2018
Resolved
Install epirb in float free arragement.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 August 2018
Resolved 13 August 2018
Resolution: Owner has repalced epirb with new one.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 7 August 2018
Resolved
Make engine room hatch watertight and install securing device.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 August 2018
Resolved 25 September 2018
Resolution: Owner has installed gaskets and locking device on the engine room hatch.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 7 August 2018
Resolved
Provide current FCC safety radio certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 August 2018
Resolved 13 August 2018
Resolution: Provided new radio safety cert.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 August 2018
Resolved
Provide 14 more type I adult lifejackets.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 August 2018
Resolved 13 August 2018
Resolution: Provided all required lifejackets.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 7 August 2018
Resolved
Install epirb in float free arrangement.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 August 2018
Resolved 13 August 2018
Resolution: Placed epirb in float free arrangement.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 7 August 2018
Resolved
Prove proper operation of lazerette high water alarm.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 August 2018
Resolved 13 August 2018
Resolution: Proved proper operation of lazerete high water alarm.
Lifesaving › Lifebuoys › Serviceable
Issued 7 August 2017
Resolved
Ring Buoy covering deteriorated. Exposed foam core. Ring Buoy not serviceable.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 August 2017
Lifesaving › Hand Flares › Quantity
Issued 9 August 2016
Resolved
Provide adequate amount of distress flares. Restricted to not operate beyond the demarkation line. 46CFR180.68
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 August 2016
Resolved 12 August 2016
Resolution: newly purchased flares on board the vessel.
Lifesaving › Lifefloat › Markings
Issued 9 August 2016
Resolved
properly mark life float & ring life buoy with name of vessel. 46CFR185.64(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 August 2016
Resolved 16 August 2016
Resolution: Operator sent photo of life float and ring buoy with proper marking of name.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 9 August 2016
Resolved
Install type II retro-reflective material on life ring buoy. 46CFR185.604(c)
Action required: 705 - Other - as specified
Due 16 August 2016
Resolved 16 August 2016
Resolution: Operator sent photo evidence of newly placed retro-reflective tape on vessels life ring buoy.