← All vessels
GAS RAY
GAS RAY is a 2003 tank ship. The Coast Guard has recorded 32 inspections since 2004, most recently in August 2021, along with 15 deficiencies and 10 operational controls.
Records from 2004 to 2021. Most recent: inspection, 9 August 2021.
- Built
- 2003
- Last inspected
- 9 August 2021
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 15 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9247209 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7YB4
666710
Flag
MARSHALL ISLANDS
—
Maury page id
psix-666710
Inspections, by type
The 32 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it6883 - Convention (Subpart B), Net Ton
22943 - Regulatory (Subpart C or D), Gross Ton
6883 - Regulatory (Subpart C or D), Net Ton
37124 - Displacement, Metric Ton
26534 - Dead Weight, Metric Ton
22943 - Convention (Subpart B), Gross Ton
22943 - Regulatory (Subpart C or D), Gross Ton
6883 - Regulatory (Subpart C or D), Net Ton
37124 - Displacement, Metric Ton
26534 - Dead Weight, Metric Ton
22943 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 32
9 August 2021
COC-GAS Renew · PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7277326
17 September 2020
COC-GAS Annual · PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7059414
7 August 2019
Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 6794981
6 August 2019
ISPS II Exam · Administrative Inspection · Ballast Water Examination · COC-GAS Renew · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6751024
21 August 2018
ISPS II Exam · Ballast Water Examination · COC-GAS Annual
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6513631
20 May 2017
ISPS II Exam · PII Safety Exam · Ballast Water Examination · COC-GAS Renew · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6150165
20 May 2017
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6151020
1 May 2012
ISPS I Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4296039
1 May 2012
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4299277
23 January 2012
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4229628
23 January 2012
ISPS I Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4229727
12 January 2012
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4223956
26 September 2011
Ballast Water Examination · COC-GAS Annual · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4152396
26 September 2011
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4154615
20 January 2011
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3929518
18 January 2011
ISPS I Exam · COE-Offshore
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3927866
18 January 2011
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3928499
16 January 2011
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3927657
11 April 2008
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3182243
7 April 2008
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3179431
3 April 2008
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3176759
14 March 2008
Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam · PII Safety Exam · COC-GAS Renew · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3161089
11 March 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3162360
21 June 2005
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2397055
21 June 2005
Type not recorded
No type recorded · Station Pascagoula · USCG Heartland District (CGD-H) · Activity 2399519
20 June 2005
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2397048
19 May 2005
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2362869
22 March 2005
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2316662
10 May 2004
MTSA/ISPS Verification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2064060
25 April 2004
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2052055
18 March 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2028263
5 February 2004
MARPOL Annex I Examination · Certificate of Compliance · MARPOL Annex V Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2000840
Deficiency record · 15
12 - Dangerous Goods › N/A - No Subsystem › Fire protection cargo deck area
Issued 6 August 2019
Resolved
Electrical installations should be such as to minimize the risk of fire and explosion from flammable products. Port State control officers observed 04 deck lights in the cargo area, located at the end of their electrical circuits, were fitted with in-used cable glands instead of appropriate explosion proof plugs.
12 - Dangerous Goods › N/A - No Subsystem › Fire protection cargo deck area
Issued 6 August 2019
Resolved
On ships carrying flamable products a water-spray system should be installed to cover exposed cargo tank domes. While testing deck Water-Spray system. Port State Control Officers observed the #1 Cargo tank Vapor dome had no water-spray coverage.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 21 August 2018
Resolved
A LIFEBOAT LAUNCHING APPLIANCE SHALL BE CAPABLE OF RECOVERING THE LIFEBOAT WITH ITS CREW. PSCO OBSERVED THE CREW WAS UNABLE TO RECOVER THE LIFEBOAT WITH THE DAVIT SYSTEM.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 27 May 2017
Resolved
0910-doors-An airlock should consist of two steel doors substantially gastight and should be self closing. Ship's weathertight door to airlock does not have self closing door. Door from airlock to motor room is warped and not providing gastight seal. IGC 3.6 10abc
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 23 May 2017
Resolved
1835-cargo vent system-pressure relief valves should be tested to ensure it opens at the prescribed pressure setting. Relief valves should be set and sealed by a competent authority acceptable to the administration. Pilot safety valve for port deck tank has compromised and missing seals. PSCO is unable to accurately identify the valves that are installed See narrative for details IGC 8.2.5 20abc
Documentation › Manuals/Policy Documentation › Cargo/Ballast System Instruction Manual
Issued 23 May 2017
Resolved
2545-reports analysis non conf-the company should establish procedures and ensure that policy is implemented and maintained at all levels of the organization to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. See narratives for details ISM Code 2 & 10 50ac
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 20 May 2017
Resolved
1835-cargo vent system-Pressure relief valves should be set and sealed by a competent auth. Acceptable to the administration. Safety valve for cargo tank 1P(Seal no 0226776) is missing tamper seals. Aux setting valves found in a bucket and seals for deck tanks are missing. IGC 8.2.5 17abc
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 20 May 2017
Resolved
1835-cargo vent sys-Each valve should be tested to ensure that it opens at prescribed pressure setting. Main and aux pilot relief valves prescribed pressure settings and test certificates issued for last drydock in March 2016 are inconsistent In addition due to improperly stowed aux setting valves and missing seals The PSCO questions the validity of the safety valves See narrative IGC 8.2.5 30abc
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 20 May 2017
Resolved
1835-cargo vent sys-the changing of the setting pressure under the provisions of 8.2.6 should be carried out in accordance with procedures approved by the administration and specified in the ships operating manual. Ship’s crew is not following approved cargo ops manual when modifying set pressures for harbor settings. IGC 8.2.7 17abc
Electrical › Lighting (service) › Grounding Conductor
Issued 26 September 2011
Resolved
0950; Intrinsically safe electrical equipment and wiring may be in a gas dangerous space or zone. 05 lights outside motor / compressor room on main deck are missing grounding straps or improperly installed, 70 A/B.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 26 September 2011
Resolved
0950; All electrical apparatus shall be so constructed and installed as not to cause injury and prevent the exposure of live electrical voltage. Throughout the house, specifically in engine and laundry room, many electrical installations were not grounded, were improperly installed and has exposed live wires, 70 A/B.
Engineering › Pressure Vessel › Weld
Issued 26 September 2011
Resolved
0430; Boilers and other pressure vessels and associated piping systems shall be of adequate construction and installed to reduce to a minimum any danger to persons on board. The hot water pressure vessel is leaking hot water, 70 A/B.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 26 September 2011
Resolved
2199; Each incinerator shall be approved by the administration taking into account the standard specification for shipboard incinerators developed by the organization. The incinerators lower door is warped and there is significant re-factory damage, 70 A/B, MARPOL V1/16.2(a).
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pressure/Vacuum Relief Valve
Issued 14 March 2008
Resolved
Both deck tank aft pressure relief valves and the CT #1 starboard pressure relief valve are missing the original tamper proof seals. Prove proper settings and sealings to the satisfaction of a competent authority acceptable to the administration.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Head
Issued 14 March 2008
Resolved
Cylinder heads #3 through #7 are leaking jacket water. Repair all leaks to the satisfaction of the vessel's classification society.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.