MAURY USCG vessel records
← All vessels

GAS RAY

Built
2003
Last inspected
9 August 2021
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 9 August 2021
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2017–2021)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9247209
666710
Flag
MARSHALL ISLANDS
Maury page id
psix-666710

Documentation record

Tonnage as PSIX records it6883 - Convention (Subpart B), Net Ton
22943 - Regulatory (Subpart C or D), Gross Ton
6883 - Regulatory (Subpart C or D), Net Ton
37124 - Displacement, Metric Ton
26534 - Dead Weight, Metric Ton
22943 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 7 inspections, each with its date, unit and type; 9 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 7

9 August 2021 COC-GAS Renew · PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7277326
17 September 2020 COC-GAS Annual · PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7059414
7 August 2019 Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 6794981
6 August 2019 ISPS II Exam · Administrative Inspection · Ballast Water Examination · COC-GAS Renew · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6751024
21 August 2018 ISPS II Exam · Ballast Water Examination · COC-GAS Annual
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6513631
20 May 2017 ISPS II Exam · PII Safety Exam · Ballast Water Examination · COC-GAS Renew · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6150165
20 May 2017 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6151020

Deficiency record · 9

12 - Dangerous Goods › N/A - No Subsystem › Fire protection cargo deck area
Issued 6 August 2019 Resolved
Electrical installations should be such as to minimize the risk of fire and explosion from flammable products. Port State control officers observed 04 deck lights in the cargo area, located at the end of their electrical circuits, were fitted with in-used cable glands instead of appropriate explosion proof plugs.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 August 2019
Resolved 7 August 2019
Resolution: Received Statement from Marshall Island (Flag) and master attesting to the repair of all deck lights.
12 - Dangerous Goods › N/A - No Subsystem › Fire protection cargo deck area
Issued 6 August 2019 Resolved
On ships carrying flamable products a water-spray system should be installed to cover exposed cargo tank domes. While testing deck Water-Spray system. Port State Control Officers observed the #1 Cargo tank Vapor dome had no water-spray coverage.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 August 2019
Resolved 6 August 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 21 August 2018 Resolved
A LIFEBOAT LAUNCHING APPLIANCE SHALL BE CAPABLE OF RECOVERING THE LIFEBOAT WITH ITS CREW. PSCO OBSERVED THE CREW WAS UNABLE TO RECOVER THE LIFEBOAT WITH THE DAVIT SYSTEM.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 21 August 2018
Resolved 21 August 2018
Resolution: Vessel's crew was able to replace the fuse that was preventing the davit recovery system from operating.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 27 May 2017 Resolved
0910-doors-An airlock should consist of two steel doors substantially gastight and should be self closing. Ship's weathertight door to airlock does not have self closing door. Door from airlock to motor room is warped and not providing gastight seal. IGC 3.6 10abc
Action required: 705 - Other - as specified
Due 27 June 2017
Resolved 27 May 2017
Resolution: Corrected on the spot.
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 23 May 2017 Resolved
1835-cargo vent system-pressure relief valves should be tested to ensure it opens at the prescribed pressure setting. Relief valves should be set and sealed by a competent authority acceptable to the administration. Pilot safety valve for port deck tank has compromised and missing seals. PSCO is unable to accurately identify the valves that are installed See narrative for details IGC 8.2.5 20abc
Action required: 705 - Other - as specified
Due 23 May 2017
Resolved 27 May 2017
Resolution: Received Class Survey Report and Tech Report verifying Port Deck Tank Safety valves operate as design pressure. Cleared def at this time.
Documentation › Manuals/Policy Documentation › Cargo/Ballast System Instruction Manual
Issued 23 May 2017 Resolved
2545-reports analysis non conf-the company should establish procedures and ensure that policy is implemented and maintained at all levels of the organization to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. See narratives for details ISM Code 2 & 10 50ac
Action required: 705 - Other - as specified
Due 23 June 2017
Resolved 27 May 2017
Resolution: Received, reviewed and accepted documentation provided. See narrative and attachment in documents for details.
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 20 May 2017 Resolved
1835-cargo vent system-Pressure relief valves should be set and sealed by a competent auth. Acceptable to the administration. Safety valve for cargo tank 1P(Seal no 0226776) is missing tamper seals. Aux setting valves found in a bucket and seals for deck tanks are missing. IGC 8.2.5 17abc
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2017
Resolution: Received, reviewed and accepted class report. See narrative for details
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 20 May 2017 Resolved
1835-cargo vent sys-Each valve should be tested to ensure that it opens at prescribed pressure setting. Main and aux pilot relief valves prescribed pressure settings and test certificates issued for last drydock in March 2016 are inconsistent In addition due to improperly stowed aux setting valves and missing seals The PSCO questions the validity of the safety valves See narrative IGC 8.2.5 30abc
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2017
Resolution: Received, reviewed and accepted class report. See narrative for details
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 20 May 2017 Resolved
1835-cargo vent sys-the changing of the setting pressure under the provisions of 8.2.6 should be carried out in accordance with procedures approved by the administration and specified in the ships operating manual. Ship’s crew is not following approved cargo ops manual when modifying set pressures for harbor settings. IGC 8.2.7 17abc
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2017
Resolution: Received, reviewed and accepted Class report see narrative for details.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.