Records from 2005 to 2025. Most recent: inspection, 23 January 2025.
Inspection history · 17
23 January 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8068817
6 February 2024
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7860933
18 January 2024
COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7844784
28 July 2023
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7754554
2 March 2023
Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7644502
21 March 2022
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7414360
8 February 2022
Deficiency Check · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7392524
19 February 2021
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7143131
8 June 2020
Administrative Inspection · DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6971040
15 April 2020
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6939633
5 February 2020
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6903053
28 January 2019
DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6615781
9 April 2018
DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6387753
6 February 2018
Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6350067
27 February 2017
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6095251
21 June 2016
DAPI Audit · Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5913975
1 February 2016
Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5807067
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 23 January 2025
Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10 (incorporated by reference, see § 175.600 of this chapter) as amended here: Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew.
Inspector found that all three of the portable fire extinguishers on board have not been receiving logged monthly inspections in accordance with manufacturers instructions.
46 CFR Part 176.810 (b) (1) (ii) 16 c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2025
Resolved 26 February 2025
Resolution: Received copy of log with section for fire extinguisher added.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 23 January 2025
Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy. The floating waterlight lanyard was not 3 ft in length and was not secured around the body of the life ring. It was also deteriorated.
46 CFR 180.70(d)(2) 16 c
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2025
Resolved 26 February 2025
Resolution: Replaced lanyard line and correctly installed.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 23 January 2025
Resolved
The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable.
No record of EPIRB monthly tests.
46 CFR 185.728(c) 16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2025
Resolved 26 February 2025
Resolution: Received copy of log with section for epirb added.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 23 January 2025
Resolved
Each watertight bulkhead must be of sufficient strength to be capable of remaining watertight with a head of water to the top of the bulkhead.
Aft manhole watertight seal was damaged.
46 CFR 179.320(a) 16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2025
Resolved 26 February 2025
Resolution: Replaced seal on manhole hatch.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 23 January 2025
Resolved
In addition to meeting § 180.130, each life float and buoyant apparatus must be stowed as required under this section, If synthetic, be of a dark color or of a type certified to be resistant to deterioration from ultraviolet light
Painter line on starboard life float was deteriorated.
46 CFR 180.137(c)(2) 16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2025
Resolved 26 February 2025
Resolution: Replaced starboard painter line.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 January 2025
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have... The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket
One of three fire buckets was not labeled.
46 CFR 181.610 16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2025
Resolved 26 February 2025
Resolution: All buckets labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 18 January 2024
Resolved
The equipment required for lifefloats and buoyant apparatus must meet the following specifications: Be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light. Replace deteriorated painter lines on both life floats.
46 CFR § 180.175
Action required: 10 - Deficiency Rectified
Resolved 22 January 2024
Resolution: Line replaced on life float, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 18 January 2024
Resolved
Except as allowed by paragraph (e) of this section, each vessel certificated to operate on a limited coastwise route in warm water must be provided with life floats of an aggregate capacity that will accommodate at least 50% of the total number of persons permitted on board. Repair cracked starboard life float to serviceable condition.
46 CFR § 180.205
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 April 2024
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 18 January 2024
Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. Replace EPIRB hydrostatic release and mark it with the expiration date accordingly.
46 CFR § 185.740
Action required: 10 - Deficiency Rectified
Resolved 18 January 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 January 2024
Resolved
In addition, a number of child size life jackets equal to at least 10% of persons permitted on board must be provided. Replace all 06 unserviceable children's lifejackets.
46 CFR § 180.71
Action required: 10 - Deficiency Rectified
Resolved 18 January 2024
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 18 January 2024
Resolved
Each EPIRB ... must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative; The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable. Master must ensure monthly test is being done and logged.
46 CFR § 185.728 (c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 April 2024
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 18 January 2024
Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: (1) Date of the drill and training; and (2) General description of the drill scenario and training topics. Master shall ensure drills are being logged IAW CFR.
46 CFR § 185.728 (f)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 April 2024
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 18 January 2024
Resolved
Fire fighting drills and training shall be logged or
otherwise documented for review by the Coast Guard upon
request. Master shall ensure drills are being logged IAW
the CFR.
46 CFR § 185.524 (d)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 April 2024
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 18 January 2024
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Replace first aid kit.
46 CFR § 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 January 2024
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 18 January 2024
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date Charts. All charts on GPS and labeled have not been updated since 2015. Update charts to the satisfaction of CG Marine Inspector.
46 CFR § 182.420(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 January 2024
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 18 January 2024
Resolved
A vessel must be provided with a main steering gear that is of adequate strength. Starboard steering rudder shaft washer is cracked. Repair/replace to the satisfaction of CG Marine Inspector.
46 CFR § 182.610(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 February 2024
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 18 January 2024
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Mount to the satisfaction of CGMI.
46 CFR 185.510
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 April 2024
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 2 March 2023
Resolved
Each vessel certificated to operate on a limited coastwise route in warm water must provide lifefloats of an aggregate cpacity that will accomodate at least 50% of the total number of persons onboard. Both lie floats are showing signs of deterioration and causing cracking of material. Lines, lights, and paddles need to be replaced. Fix material with an approved repair kit.
Vessel is limited to no more than 3 NM from shore and no more than 20 NM from a harbor of safe refuge.
46 CFR 180.205(c)
Action required: 705 - Other - as specified
Resolved 28 July 2023
Resolution: Attended vessel and inspected new/repaired life float. All Satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 21 March 2022
Resolved
Vessel must carry one floating waterlight. Waterlight battery expired, replace battery.
46CFR180.70(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 April 2022
Resolved 31 March 2022
Resolution: Owner provided a video with the waterlight working properly.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 March 2022
Resolved
Protect passenger, crew, vessel from electrical hazards. Properly install cable above steering gear.
46CFR183.200(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 April 2022
Resolved 31 March 2022
Resolution: Owner provided pictures covering the cable reducing electrical hazard.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 19 February 2021
Resolved
Each Survival craft must be secured to the vessel by a painter with a float-free link permanently attached to the vessel. The vessel did not have a float free link installed and the painter needs to be replaced due to UV damage.
46 CFR 180.130(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 March 2021
Resolved 11 March 2021
Resolution: Vessel replaced the float-free link.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 19 February 2021
Resolved
A hatch exposed to the weather must be watertight. The steering gear space's hatch has a watertight gasket which has partially fallen off and no longer provides a watertight seal.
46 CFR 179.360(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 March 2021
Resolved 11 March 2021
Resolution: Vessel replaced the gasket.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 19 February 2021
Resolved
Boundaries that separate machinery spaces from accommodation spaces... must be lined with noncombustible panels or insulation. The engine room hatch's insulation is partially missing and falling off the hatch covers.
46 CFR 177.410(c)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 March 2021
Resolved 11 March 2021
Resolution: Vessel replaced insulation on engine room hatch.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 February 2021
Resolved
At least one ring life buoy must be fitted with a lifeline. The lifeline on the ring buoy needs to be replaced due to UV damage.
46 CFR 180.70(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 March 2021
Resolved 11 March 2021
Resolution: The vessel's lifeline has been replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 February 2021
Resolved
Each rescue boat and ring life buoy must be marked with type II retro-reflective material. The ring life buoy's retro-reflective material was peeling off.
46 CFR 185.604(i)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 March 2021
Resolved 11 March 2021
Resolution: The vessel replaced the retro reflective tape.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 February 2021
Resolved
Each ring life buoy with a floating water-light must have a lanyard of at least 910 millimeters (3 ft). The floating water-light's lanyard needs to be replaced due to UV damage.
46 CFR 180.70(d)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 March 2021
Resolved 11 March 2021
Resolution: Vessel replaced floating water-light.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 8 June 2020
Resolved
FCC Safety Certificate is expired. Vessel is to schedule for FCC inspection. 46CFR184.502
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2020
Resolved 16 June 2020
Resolution: FCC certificate received.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 8 June 2020
Resolved
EPIRB hydrostatic release has expired date marked on it. Replace in kind. Vessel restricted to three miles from shore.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 16 June 2020
Resolution: New hydro static release onboard.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 12 April 2018
Resolved
Connect floating waterlight with lanyard between 3 feet - 6 feet long.
Action required: 705 - Other - as specified
Due 16 April 2018
Resolved 12 April 2018
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure
Issued 9 April 2018
Resolved
Replace portable fire extinguisher located fwd main deck s/s B:C Type II.
Action required: 705 - Other - as specified
Due 11 April 2018
Resolved 9 April 2018
Resolution: Replaced with new extinguisher.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 27 February 2017
Resolved
Repair 02 floating water lights. Vessel is restricted to daytime operations only until repairs are made.
Action required: 705 - Other - as specified
Due 6 March 2017
Resolved 28 February 2017
Resolution: Batteries replaced in all three water lights.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 June 2016
Resolved
Ensure First Aid Kit contains items listed in 46 CFR 160.041
Action required: 705 - Other - as specified
Due 5 July 2016
Resolved 18 July 2016
Resolution: Vessel provided proof of required first aid kit items.
Construction/Loadline › Hull › Side Shell
Issued 1 February 2016
Resolved
Vessel had delaminating FRP located at the transom to the left of the port side exhaust.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 3 February 2016
Resolution: Vessel made repairs to damaged FRP at the transom. Grinded back to good fiberglass then rebuilt it with Wes System.