MAURY USCG vessel records Sign in
← All vessels

DA YING

DA YING is a 2003 freight ship. The Coast Guard has recorded 24 inspections since 2004, most recently in September 2016, along with 15 deficiencies and 6 operational controls.

Records from 2004 to 2016. Most recent: inspection, 24 September 2016.

Built
2003
Last inspected
24 September 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9254525 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
667025
Flag
PANAMA
—
Maury page id
psix-667025

Inspections, by type

…with no type recorded11
Years with a record 8 calendar years (2004–2016)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it25277 - Convention (Subpart B), Net Ton
75318 - Dead Weight, Ton
85838 - Displacement, Ton
39691 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 24

24 September 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6008209
28 October 2014 Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5009352
1 October 2014 ISPS II Exam · Deficiency Check · Ballast Water Examination · PII Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4995858
14 October 2010 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3865494
5 December 2008 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3365837
26 November 2008 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3370169
17 February 2008 Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 3149551
12 February 2008 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3146100
26 September 2007 ISPS II Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3066949
22 September 2007 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3063508
17 March 2007 Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 2890371
15 March 2007 ISPS I Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2888607
15 March 2007 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2888704
14 March 2007 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2888078
28 October 2006 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2809765
20 October 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2804881
12 October 2006 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2799074
13 March 2006 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2601696
8 March 2006 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2598918
8 November 2005 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2563380
16 June 2005 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2392635
22 July 2004 ISPS II Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2141444
30 January 2004 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2007008
29 January 2004 Annual Inspection · Ballast Water Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1996200

Deficiency record · 15

Lifesaving › Launching Appliances › Winch Brake
Issued 1 October 2014 Resolved
0630-Launch arrangement for survival craft-Unless expressly provided otherwise, launching and embarkation appliances complying with the requirements of section 6.1 of the Code shall be provided for all survival craft...Continued in Narrative of Activity #4995858 - 74SOLAS(09) III/16.1-LSA Code 6.1.2.12 (30abc)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 October 2014
Resolved 5 October 2014
Resolution: Item Corrected to the satisfaction of the attending Classification Representative.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 1 October 2014 Resolved
0720-firefighting equipment; Ships equipped with helidecks shall comply with the requirements of this regulation. In close proximity to the helidecks, the following fire-fighting appliances shall be provided and stored near the means of access to that helideck. Two fire-fighting outfits additional to the required in II-2/10.10 not onboard the vessel, 74SOLAS(09II-2/18.2.1-II-2/18.5.1.6 (17ac).
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 1 October 2014
Resolved 5 October 2014
Resolution: Item Corrected to the satisfaction of the attending Classification Representative. Fire suits for the Helideck were purchased and place on board.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 1 October 2014 Resolved
0799; Fire Control Plans and booklets shall be kept up to date. Current Fire Control Plans onboard do not list additional fire fighting appliances for helideck, SOLAS 74 (09) II-1, Reg., 15.2.4.1., 40A/C.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 17 October 2014
Resolved 5 October 2014
Resolution: Item Corrected to the satisfaction of the attending Classification Representative.
Deck/Cargo › Mooring/Anchoring › Clutch
Issued 1 October 2014 Resolved
0999; The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons. Ship has hydraulic leak in port mooring winch and cargo control box on deck between cargo holds 3/4 has water and hydraulic leak, SOLAS 74 (09), I/11, 40AC.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 17 October 2014
Resolved 5 October 2014
Resolution: Item Corrected to the satisfaction of the attending Classification Representative.
Accommodation/Occupational Safety › Potable Water System › General
Issued 1 October 2014 Resolved
1499; In addition to the requirements contained elsewhere in the present regulations, ships shall be designed, constructed, and maintained in compliance with the structural mechanical requirements of a classification society. Fresh water tank in engine room aft bulkhead near start air compressors was disconnected from service and still pressured, 74(04)II-1/3-1, 40AC.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 17 October 2014
Resolved 5 October 2014
Resolution: Item Corrected to the satisfaction of the attending Classification Representative. Item was not required and removed from service.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 1 October 2014 Resolved
1499; The machinery and associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. The OWS system has a patch on the inlet of the first stage. The salt water outlet, connecting to the main engine fresh water cooler, was repaired with a weld 01 month ago. There is no qualified fitter onboard, see narrative for details.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 17 October 2014
Resolved 5 October 2014
Resolution: Item Corrected to the satisfaction of the attending Classification Representative.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 1 October 2014 Resolved
Every ship 100 gross tons and above shall carry a garbage management plan, which the crew shall provide written procedures for collecting, storing, processing and disposing of garbage. Vessel has a garbage management plan but it is not being followed by the crew, which is resulting in mixed garbage. In addition, see narrative for details.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 October 2014
Resolved 1 October 2014
Resolution: Discussed items with the [name withheld] and Chief Engineer.
Documentation › Logs/Records › Ballast Water Reporting Form
Issued 1 October 2014 Resolved
2510; Vessel must maintain a Ballast Water Management Plan that has been developed specifically for the vessel that will allow those responsible for the plan to understand and follow it. Vessel is currently is not following or documenting items, 33 CFR 151.2050(g), 10C.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 October 2014
Resolved 1 October 2014
Resolution: Discussed items with the Captain and [name withheld].
Lifesaving › Lifebuoys › Immediately Available
Issued 5 December 2008 Resolved
Life ring missing from starboard life boat deck, posing safety risk to crew. Cite: 2004 SOLAS III Reg 20. Action taken: 10C
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 5 December 2008
Resolution: Life ring was immediately replaced.
Lifesaving › Launching Appliances › Davit
Issued 5 December 2008 Resolved
Lifeboat took 30 minutes for crew to lower, posing risk to crew. (Second drill took less than 5 minutes). Cite: 2004 SOLAS III Reg 20. Action taken: 10C.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 5 December 2008
Resolution: Conducted another drill, where crew was able to lower lifeboat in less than 5 minutes.
Fire Fighting › Means of Escape › Doorways
Issued 5 December 2008 Resolved
Door from steering room padlocked from outside, posing safety risk to crew. Cite: 2004 SOLAS XI-2 Reg 8.2 Action taken 10C.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 5 December 2008
Resolution: Crew unlocked padlock and was told to leave unlocked from here out.
Lifesaving › Lifeboat Equipment › First Aid Kit
Issued 26 September 2007 Resolved
First Aid kits for the life boats were stored in the ship's office and not in the lifeboats creating a safety risk for Abandon Ship. Solas 04 CH III Reg 31.1 LSA Code CH 4.6.1 10c
Action required: 705 - Other - as specified
Resolved 28 September 2007
Resolution: First Aid Kits were properly stowed in the lifeboats.
Operations/Management › Pollution › Control of Garbage
Issued 26 September 2007 Resolved
Ship's Garbage Record Book did not contain proper entries for each discharge to reception facitlity. MARPOL Annex V, Reg 9 (3) (6) 10c
Action required: 705 - Other - as specified
Resolved 28 September 2007
Resolution: The Chief Mate was instructed on what the proper method iin recording activity into Garbage Record Book and demonstrated clear understanding on instructions.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 12 October 2006 Resolved
Vessel did not have the non-tank vessel response plan onboard at the time of inspection. Vessel company to submit non-tank vessel response to Coast Guard for approval prior to next U.S port after sailing foreign.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 28 September 2007
Resolution: Inspected by the Coast Guard to be satisfactory. Sector Seattle
Construction/Loadline › Markings › Load Line Mark
Issued 12 October 2006 Resolved
Load line markings on vessel hull did not match the markings on vessels load line certificate.
Action required: 705 - Other - as specified
Due 13 October 2006
Resolved 13 October 2006
Resolution: Corrected on the spot.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.