MAURY USCG vessel records Sign in
← All vessels

CARIBE LEGEND

CARIBE LEGEND is a 1992 freight ship. The Coast Guard has recorded 74 inspections since 2004, most recently in May 2026, along with 31 deficiencies and 5 operational controls.

Records from 2004 to 2026. Most recent: inspection, 26 May 2026.

Built
1992
Last inspected
26 May 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9061289 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
667479
Flag
ANTIGUA AND BARBUDA
—
Maury page id
psix-667479

Inspections, by type

…with no type recorded15
Years with a record 22 calendar years (2004–2026)
The 74 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it2233 - Convention (Subpart B), Net Ton
5327 - Dead Weight, Ton
7691 - Displacement, Ton
3992 - Simplified, Gross Ton
3992 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 74

26 May 2026 Deficiency Check · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8380578
24 November 2025 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8273099
20 May 2025 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8139511
8 November 2024 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8032380
30 October 2024 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8026599
22 May 2024 Administrative Inspection · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7916946
24 March 2024 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7882781
8 September 2023 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7784322
30 November 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7602114
1 November 2022 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7586843
26 April 2022 Deficiency Check · Administrative Inspection · Ballast Water Examination · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7437947
26 October 2021 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7339395
21 April 2021 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7179086
15 November 2020 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7094679
26 July 2020 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7016363
14 May 2020 Administrative Inspection · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6953716
23 December 2019 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6878209
21 October 2019 ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6838831
18 April 2019 PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6664404
18 October 2018 Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6563238
19 April 2018 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6394246
16 October 2017 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6288723
20 April 2017 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6128303
20 October 2016 ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6026174
3 May 2016 PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5868053
1 December 2015 Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5772896
6 November 2015 ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5758568
30 October 2014 ISPS III Exam · PII Safety Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5014423
16 October 2014 Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5006304
15 May 2014 Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4859049
21 January 2012 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4229025
1 February 2011 Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3937063
25 January 2011 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3932383
12 January 2011 Deficiency Check · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3925275
15 November 2010 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3891535
24 January 2010 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3665558
12 January 2010 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3662621
11 January 2010 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3662002
6 January 2010 Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3659772
8 December 2009 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3647183
15 March 2009 ISPS III Exam · Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3433656
26 January 2009 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3400419
5 January 2009 Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3388980
16 June 2008 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3239027
3 June 2008 Deficiency Check · ISPS III Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3226422
3 June 2008 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3227238
24 February 2008 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3152431
12 February 2008 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3144918
20 June 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2968356
20 June 2007 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2968567
15 June 2007 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2962846
27 April 2007 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2916744
2 April 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2899785
28 March 2007 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2926278
7 February 2007 ISPS II Exam · PII Safety Exam · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2868852
2 May 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2639398
27 April 2006 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2635179
5 February 2006 ISPS II Exam · NPV Safety Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2579585
25 July 2005 PII Safety Exam · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2439574
26 April 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2343920
25 April 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2343040
29 March 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2322363
22 March 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2316649
15 March 2005 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2310297
16 February 2005 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2293528
27 January 2005 ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2281577
18 August 2004 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2167901
30 July 2004 PII Safety Exam
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2150117
2 July 2004 ISPS II Exam
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2118078
28 May 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2085198
29 April 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2060609
16 April 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2047309
31 March 2004 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2034747
28 January 2004 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1994946

Deficiency record · 31

07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 26 May 2026 Resolved
IN A SHIP IN WHICH OIL FUEL IS USED, THE ARRANGEMENTS FOR THE STORAGE, DISTRIBUTION AND UTILIZATION OF THE FUEL SHALL BE SUCH AS TO ENSURE THE SAFETY OF THE SHIP AND PERSONS ON BOARD. PSCO'S OBSERVED A FUEL OIL LEAKE FROM THE #6 CYLINDER.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 May 2026
Resolution: Verified no fuel oil leak after new part was installed.
01 - Certificates & Documentation › 012 - Crew Certificates › Endorsement by flagstate
Issued 26 May 2026 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 May 2026
Resolution: Verified new Chief Engineer aboard had valid license and endorsement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 26 May 2026 Resolved
THE MACHINERY, BOILERS, AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHIC THEY ARE INTENDED. PSCO'S OBSERVED MULTIPLE GAUGES ON THE #1 AUX ENGINE NOT WORKING AND THE LUBE OIL PRESSURE GAUGE ON THE EDG NOT WORKING.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2026
Resolved 29 May 2026
Resolution: Verified new EDG gauges were operational.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 30 October 2024 Resolved
The opening below the lowest course of the guard shall not exceed 230 mm. The other courses shall not be more than 380 mm apart. PSCOs observed the middle course rail missing on the forward most STBD side railing bracket. 1966 ILLC Part 1 Reg. 25 (3)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2024
Resolved 8 November 2024
Resolution: Received company report attesting repairs and installation of railings missing identify during last PSC exam.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 30 October 2024 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts...PSCOs observed missing protection bracket on rotating belt on compressor in steering space. 74 SOLAS (04 Cons.) Ch. II-1 Reg. 26.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 October 2024
Resolved 30 October 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 May 2024 Resolved
Under all sailing conditions, including maneuvering, the speed, direction of thrust and, if applicable,the pitch of the propeller shall be fully controllable from the navigation bridge. PSCO were notified that the throttle on the navigation bridge was not communicating with the CPP. 74 SOLAS CH II-1 Reg. 49 .1
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 June 2024
Resolution: recieved class documents attesting to rectification
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 8 September 2023 Resolved
Each operation described in paragraph 2 of this regulation shall be fully recorded without delay in the oil record book part I, so that all entries in the book appropriate to that operation are completed. Oil Record Book was missing a bunkering of fuel operation entry. MARPOL I/17.4
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2023
Resolved 12 September 2023
Resolution: Vessel sent documentation of the bunkering entry properly recorded in the Oil Record Book.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 1 November 2022 Resolved
All access openings in bulkheads at ends of enclosed superstructures shall be fitted with doors of steel or other equivalent material permanently and strongly attached to the bulkhead , and framed, stiffened and fitted so that the whole structure is of equivalent strenght to the unpierced bulkhead and weathertight when closed. PSCOs observed daylight pretruding through weathertight door leading to CO2 room on the main deck. ICLL(66)ANNEX I, CHAPTER II/12(1). 50ac.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2022
Resolved 30 November 2022
Resolution: Received Class Report from [name withheld] attesting to repair of deteriorated weathertight door. Old gasket was removed and replaced while the door frame was derusted, chipped, and sanded. Photos provided of repair process and final product.
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management Plan (BWMP)
Issued 26 April 2022 Resolved
Maintain a ballast water management plan that has been developed specifically for the vessel. The plan must include actions for implementing the mandatory BWM requirements and practices. Vessels plan listed ballast water exchange sequential method as an option for discharging ballast water. Since vessel has no BWTS that option is not allowed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2022
Resolved 5 May 2022
Resolution: Received updated approved section of the BWMP from the RO
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 26 April 2022 Resolved
The fire resistance of doors shall... Doors fitted in boundary bulkheads of machinery spaces of category A shall be reasonably gastight and self-closing. PSCO's observed 02 emergency escape doors in engine room with missing locking mechanisms in keyholes rendering the A class doors as not gastight. In addition, the escape door on upper deck of the engine room did not latch properly.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2022
Resolved 5 May 2022
Resolution: Received RO attestation letter, doors in ER have been repaired and were tested SAT.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 November 2020 Resolved
...The activation of any detector...shall initiate a visual and audible signal at the control and indicating units. Smoke detector in steering gear room was inoperable when tested; test did not activate any alarms. 74 SOLAS 97 (cons.) II-2/ Reg. 13.1.4
Action required: 10 - Deficiency Rectified
Due 15 November 2020
Resolved 15 November 2020
Resolution: Resolved while PSCO on ship by replacement.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 November 2020 Resolved
Every lifebuoy shall... if it is intended to be quick release arrangement...have a mass of 4 kg. Both lifebuoys on bridge wings were below the 4kg weight requirement. 74 SOLAS 14 III/Reg. 7.1.1
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2020
Resolved 20 November 2020
Resolution: PSCOs received invoice and pictures for two quick release 4Kg life buoys
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 15 November 2020 Resolved
Every liferaft shall be stowed with its painter permanently attached to the ship. Liferaft painter was found detached from the hydrostatic release weak-link. 74 SOLAS 14 III/ Reg. 13.4.1
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 15 November 2020
Resolved 15 November 2020
Resolution: Resolved while PSCO on board by properly installing painter.
Communications › Radio Communications › Satellite Communications Capability
Issued 19 April 2018 Resolved
SOLAS 2014 (CONS) REG 10.1.1 SHIPE ENGAGED ON VOYAGES WITH IN AREA A1 AND A2, BUT REMAINING WITHIN A3 SHALL BE PROVIDED WITH INMARSAT SHIP EARTH STATION. INMARSAT CURRENTLY NON FUNCTIONAL. ACTION TAKEN 50C
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2018
Resolved 26 April 2018
Resolution: received tech report attesting to proper operation
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 19 April 2018 Resolved
33CFR 164.53(B) IF THE VESSEL'S RADIO NAVIGATION RECIEVERS ARE NOT OPERATING PROPERLY, THE PERSON DIRECTING THE MOVEMENT OF THE VESSEL MUST REPORT TO THE NEAREST CAPTAN OF THE PORT. PSC OFFICER OBSERVED THAT INMARSAT WAS NON FUNCTIONING AND NOT REPORTED. ACTION TAKEN 10C
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 19 April 2018
Lifesaving › Inflatable Liferafts › Servicing
Issued 3 May 2016 Resolved
Every inflatable liferaft shall be serviced at intervals not exceeding 12 months. Liferaft servicing was due by the end of April on the starboard side raft.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 May 2016
Resolved 3 May 2016
Resolution: Replacement raft provided for vessel before departure from port.
Construction/Loadline › Penetrations › Gasket
Issued 10 November 2015 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulation to ensure that the ship in all respect remain fit to proceed to sea without danger to the crew.The watertight doors in the forecastle are missing gaskets (crew removed it for maintanence), compromising watertight integrity.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 November 2015
Resolved 10 November 2015
Resolution: Class report attesting to proper repair was received and accepted by USCG.
Fire Fighting › Fixed Fire Detection System › Detector/Call Point Grouping
Issued 10 November 2015 Resolved
A fixed-fire detection and fire alarm system shall be installed in the main propulsion and associated machinery. 04 smoke detectors in the E/R failed to activate during testing.
Action required: 705 - Other - as specified
Due 24 November 2015
Resolved 1 December 2015
Resolution: All fire alamrs were successfully tested.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 10 November 2015 Resolved
Where necessary, a non-conducting mat or grating shall be provided at the front and rear of the switchboard. Non-conducting mats are not in place.
Action required: 705 - Other - as specified
Due 24 November 2015
Resolved 1 December 2015
Resolution: Rubber mats were provided at all locations, including engine room and forecastle.
Documentation › Logs/Records › Oil Record Book
Issued 10 November 2015 Resolved
Oil Record Book Part I shall be completed for discharging bilge water overboard. C/E overstated the OWS through-put in the ORB because he did not know capacity of the pump (2.5 M^3/hr).
Action required: 705 - Other - as specified
Due 24 November 2015
Resolved 1 December 2015
Resolution: Entries in the Oil Record Book are now properly made.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 10 November 2015 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulation to ensure that the ship in all respect remain fit to proceed to sea without danger to the crew. Vent cover for AC room and Galley door are missing.
Action required: 705 - Other - as specified
Due 24 November 2015
Resolved 1 December 2015
Resolution: Vent covers were provided in the A/C room and galley locations.
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 16 October 2014 Resolved
Vessel arrived in the Port of Palm Beach without meeting the required Notice of Arrival submitting time frame.
Action required: 15 - Rectify deficiencies by next port
Due 16 October 2014
Resolved 20 October 2014
Resolution: Vessel submitted a proper Notice of Arrival.
Electrical › Electric Generation Source (emergency) › Generator
Issued 21 January 2012 Resolved
2050 - Where automatic starting is not required, manual starting is permissible, such as power charge cartridges, where they can be demonstrated as being effective. Vessel could not provide backup starting arrangements for the emergency generator due to lack of parts. SOLAS 74/04 Ch. II-I Reg.44 (50c)
Action required: 705 - Other - as specified
Due 21 February 2012
Resolved 10 February 2012
Resolution: Vessel submitted class report that attested to the def. "Installed double set of starting batteries. Tested new installation satisfactory."
Communications › Radio Communications › EPIRB
Issued 12 January 2011 Resolved
EPIRB is overdue for annual servicing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 January 2011
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 12 January 2011 Resolved
During steering gear test USCG observed that the alarm indicator panel does not identify loss of power to the steering gear pumps. Have administration/class attest to the proper operation of the system.
Action required: 705 - Other - as specified
Due 20 March 2011
Resolved 1 February 2011
Resolution: Received Class report attesting to proper operation of alarm indicator panel.
Engineering › Fuel Oil Service System › Valve, Control
Issued 3 June 2008 Resolved
C/E determined that the lube oil pressure sensor was malfunctioning and was replaced and MDE working properly. Verified by marine inspector, pending classification attestation to operational tests of MDE.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 17 June 2008
Resolution: Received a class report from Bureau Veritas asstesting to the satisfactory test of the Main Diesel Engine. 01 Requirements cleared, 0 Requirements remain outstanding.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 10 February 2008 Resolved
Vessels load line is improperly marked on the vessels hull, the load line is on the left side of the plimsoll (STBD SIDE OF THE VESSEL) and is marked like Timber line on the load line certificate. Vessel is to remark the load line in accordance with the load line certificate
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 12 March 2008
Resolved 26 February 2008
Resolution: The def issued was a mistake on coast guard boarding team part. Cleared def for this reason.
Documentation › Manuals/Policy Documentation › Maneuvering Information
Issued 10 February 2008 Resolved
Vessel is missing the warning statement on the maneuvering fact sheet... 33CFR164.37(g)(7)
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 19 February 2008
Resolved 26 February 2008
Resolution: Vessel added a warning statement to maneuvering fact sheet.
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 10 February 2008 Resolved
Vessel is missing its garbage management plan. Vessel is to ensure garbage management plan is onboard and implemented.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 March 2008
Resolved 26 February 2008
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 8 February 2007 Resolved
Discovered no audible alarm on bridge when loss of steering power test was conducted. Further, received report that main switchboard was sent to Germany for repairs, engine room is manned 24 hours and the audible alarm is working properly in that space. Allowing for 30 days to have corrected def.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 March 2007
Resolved 28 March 2007
Resolution: Audible steering casualty alarm on bridge repaired to the satisfaction of attending class surveyor.
Documentation › Safety/Response Plans/Programs › Ballast Water Management Plan
Issued 7 February 2007 Resolved
Vessel does not have a Ballast Water Management Plan.
Action required: 705 - Other - as specified
Due 7 March 2007
Resolved 1 May 2007
Resolution: Vessel has an approved Ballast Water Mangement Plan from thier RO.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.