Records from 2004 to 2021. Most recent: inspection, 23 June 2021.
Inspection history · 21
23 June 2021
PSC A · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7232691
6 September 2017
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6261206
5 December 2016
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6052711
10 February 2012
MARPOL Annex VI Survey · ACP Handover Survey · MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4227225
18 November 2010
Annual Inspection · MARPOL Annex IV Survey · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3894321
26 February 2010
MARPOL Annex I Examination · Annual Inspection · MARPOL Annex VI Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3700679
24 December 2009
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3802631
18 February 2009
MARPOL Annex VI Survey · MARPOL Annex I Examination · COI Inspection · Hull Examination · Internal Structural Exam · MTSA/ISPS Verification · Cargo Tank Internal
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3398161
14 August 2008
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3298243
10 April 2007
Ballast Water Examination · Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2904946
30 March 2007
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2898260
19 January 2007
Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2858575
29 June 2006
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2695043
18 April 2006
Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2627204
5 July 2005
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2420480
18 May 2005
MTSA/ISPS Verification · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2361719
16 February 2005
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2293573
14 January 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2274915
2 July 2004
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2119062
5 May 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2060807
18 February 2004
Initial Certification · Initial Construction-Excluding Oversight · Inclining Experiment
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2027110
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Approval
Issued 10 February 2012
Resolved
Replace all portable fire extinguishers with those that are CG approved.
Action required: 705 - Other - as specified
Due 10 March 2012
Resolved 13 April 2012
Resolution: Made into Lloyds class deficiency.
Lifesaving › Lifebuoys › Approval
Issued 10 February 2012
Resolved
Replace port and stbd bow liferings to those that are CG approved.
Action required: 705 - Other - as specified
Due 10 March 2012
Resolved 13 April 2012
Resolution: Made into Lloyds class deficiency.
Fire Fighting › Fire Hoses › Material
Issued 10 February 2012
Resolved
Replace all Brazilian fire hoses to those that are CG approved.
Action required: 705 - Other - as specified
Due 10 March 2012
Resolved 13 April 2012
Resolution: Made into Lloyds class deficiency.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 10 February 2012
Resolved
Re-label port and stbd aft deck cargo pump shutdowns.
Action required: 705 - Other - as specified
Due 10 March 2012
Resolved 13 April 2012
Resolution: Made into Lloyds class deficiency.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 10 February 2012
Resolved
Provide and install blank for electrical panel 2L.
Action required: 705 - Other - as specified
Due 10 March 2012
Resolved 13 April 2012
Resolution: Made into Lloyds class deficiency.
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 10 February 2012
Resolved
Provide and install dryer exhaust hose in Laundry Room.
Action required: 705 - Other - as specified
Due 10 March 2012
Resolved 13 April 2012
Resolution: Made into Lloyds class deficiency.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 10 February 2012
Resolved
Remove extension cord and provide electrical outlet for washer in Laundry Room.
Action required: 705 - Other - as specified
Due 10 March 2012
Resolved 13 April 2012
Resolution: Made into Lloyds class deficiency.
Stability › Watertight Integrity › General
Issued 10 February 2012
Resolved
Adjust Bow Thruster and Z-Drive Room watertight doors.
Action required: 705 - Other - as specified
Due 10 March 2012
Resolved 13 April 2012
Resolution: Made into Lloyds class deficiency.
Stability › Watertight Integrity › General
Issued 10 February 2012
Resolved
Repair handwheel, renew gasket, and adjust Z-Drive Room emergency escape hatch.
Action required: 705 - Other - as specified
Due 10 March 2012
Resolved 13 April 2012
Resolution: Made into Lloyds class deficiency.
Lifesaving › Rescue Boat Equipment › First Aid Kit
Issued 10 February 2012
Resolved
Provide CG approved portable fire extinguisher and first aid kit and replace fuel hose from tank to outboard.
Action required: 705 - Other - as specified
Due 10 March 2012
Resolved 13 April 2012
Resolution: Made into Lloyds class deficiency.
Lifesaving › Rescue Boat › Hull (combination rigid/inflated)
Issued 10 February 2012
Resolved
Conduct maintenance on rescue boat by repairing hull and sponson and replacing retro-reflective tape.
Action required: 705 - Other - as specified
Due 10 March 2012
Resolved 13 April 2012
Resolution: Made into Lloyds class deficiency.
Accommodation/Occupational Safety › Ventilation › General
Issued 10 February 2012
Resolved
Make permanent repairs to or replace Emergency Generator Room vents and closures.
Action required: 705 - Other - as specified
Due 10 March 2012
Resolved 13 April 2012
Resolution: Made into Lloyds class deficiency.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 10 February 2012
Resolved
Replace hoses or tag-out #1 generator hot start.
Action required: 705 - Other - as specified
Due 10 March 2012
Resolved 13 April 2012
Resolution: Made into Lloyds class deficiency.
Engineering › Fuel Oil Service System › Hose
Issued 10 February 2012
Resolved
Replace #1 generator fuel return hose with one meeting SAE J-1942 Standard.
Action required: 705 - Other - as specified
Due 10 March 2012
Resolved 13 April 2012
Resolution: Made into Lloyds class deficiency.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 10 February 2012
Resolved
Provide guards for Control Room bench grinder.
Action required: 705 - Other - as specified
Due 10 March 2012
Resolved 13 April 2012
Resolution: Made into Lloyds class deficiency.
Fire Fighting › Portable Foam Applicators › General
Issued 10 February 2012
Resolved
Locate Engine Room AFFF extinguishing equipment in accordance with the Fire & Safety Plan.
Action required: 705 - Other - as specified
Due 10 March 2012
Resolved 13 April 2012
Resolution: Made into Lloyds class deficiency.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 10 February 2012
Resolved
Update Periodic Safety Test procedures to reflect current equipment and methods of testing and submit for approval.
Action required: 705 - Other - as specified
Due 10 March 2012
Resolved 13 April 2012
Resolution: Made into Lloyds class deficiency.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 10 February 2012
Resolved
Provide caps for Emergency Generator Room and Engine Room sounding tubes or install flame screens.
Action required: 705 - Other - as specified
Due 10 March 2012
Resolved 13 April 2012
Resolution: Made into Lloyds class deficiency.
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 10 February 2012
Resolved
Update SOLAS training manual and provide in Mess Room.
Action required: 705 - Other - as specified
Due 10 March 2012
Resolved 13 April 2012
Resolution: Made into Lloyds class deficiency.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 10 February 2012
Resolved
Provide guard for reefer light.
Action required: 705 - Other - as specified
Due 10 March 2012
Resolved 13 April 2012
Resolution: Made into Lloyds class deficiency.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 10 February 2012
Resolved
Adjust Bridge and Main Deck fire doors leading to stairwell.
Action required: 705 - Other - as specified
Due 10 March 2012
Resolved 13 April 2012
Resolution: Made into Lloyds class deficiency.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 10 February 2012
Resolved
Provide proof of compass calibration.
Action required: 705 - Other - as specified
Due 10 March 2012
Resolved 13 April 2012
Resolution: Made into Lloyds class deficiency.
Fire Fighting › Grease Extraction Hood › General
Issued 10 February 2012
Resolved
Label Gally oven shutdown.
Action required: 705 - Other - as specified
Due 10 March 2012
Resolved 13 April 2012
Resolution: Made into Lloyds class deficiency.
Lifesaving › Inflatable Liferafts › Servicing
Issued 1 December 2010
Resolved
Have Viking liferafts serviced at a US Coast Guard approved servicing facility.
Due 1 February 2011
Resolved 3 February 2011
Documentation › Logs/Records › Oil Record Book
Issued 18 November 2010
Resolved
Provide Bunker Delivery Notes (BDN) along with each bunker delivery sample. BDNs shall be maintained onboard for at least three years.
Due 1 December 2011
Resolved 3 November 2011
Resolution: Reviewed the Bunker Delivery Notes and fuel samples for the past year, all sat.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 26 February 2010
Resolved
Conduct an annual test of the vessel's automation IAW USCG approved automation test procedures dated March 17, 2003 IAW 46 CFR 61.40-6 (b) and provide a complete report of the test results to Sector NOLA.
Action required: 705 - Other - as specified
Due 26 March 2010
Resolved 30 April 2010
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 26 February 2010
Resolved
The positive shut-off valve for the starboard MT #13 is a butterfly valve with a buna N seat. This valve does not meet the construction requiremnets for valves installed outside of fuel tanks IAW 46 CFR56.50-60 (d) (1). Prior to carring fuel in MT #13 install a positive shut-off valve IAW 46 CFR 56.50-60 9d) (1)
Action required: 705 - Other - as specified
Due 26 March 2010
Resolved 28 April 2010
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Crankshaft
Issued 26 February 2010
Resolved
The crankshaft real seals on the #2 & #3 generators seta are leaking excessively and slinging oil onto the deck plates. Replace the cranckshaft rear seals on both generators.
Action required: 705 - Other - as specified
Due 26 March 2010
Resolved 28 April 2010
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 26 February 2010
Resolved
Conduct and annual audit of the vessel's SOPEP
Action required: 705 - Other - as specified
Due 26 March 2010
Resolved 28 April 2010
Construction/Loadline › Hull › Hull Plating
Issued 26 February 2010
Resolved
The hull plate around the port aft grid coller is leaking sea water into the engineroom. A cofferdam has beem constructed around the grid cooler as a temp repair. Coduct permanent repairs to the hull plate.
Action required: 705 - Other - as specified
Due 26 March 2010
Resolved 28 April 2010
Engineering › Thrusters › Hose
Issued 26 February 2010
Resolved
replace port Z drive cooling water hose
Action required: 705 - Other - as specified
Due 26 March 2010
Resolved 28 April 2010
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 26 February 2010
Resolved
Provide two fire resistant hoods for the fireman's outfit
Action required: 705 - Other - as specified
Due 26 March 2010
Resolved 30 April 2010
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 18 February 2009
Resolved
The fuel oil, mud, and ballast system have been altered. Submit revised plans for the fuel oil , mud, and ballast system to sector new orleans IAW 46 cfr 126.150(a).
Due 20 April 2009
Resolved 29 April 2009
Lifesaving › Inflatable Liferafts › Servicing
Issued 18 February 2009
Resolved
Place two additonal 25 person liferafts onboard the vessel in a float free arrangment untill two new liferaft clear Brazilian customs but in no case later than 27 Feb 2009.
Action required: 705 - Other - as specified
Due 27 February 2009
Resolved 1 March 2009
Communications › Alarms/Indicators › Bilge Alarm
Issued 10 April 2007
Resolved
Provide proof of valid automation alarm testing from 3rd party to marine inspector
Due 10 May 2007
Resolved 27 April 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 10 April 2007
Resolved
Install CO2 sign at remote location directing crew members to CO2 station if remote controls fail
Due 10 April 2007
Resolved 27 April 2007
Engineering › Fuel Oil Service System › Flange
Issued 10 April 2007
Resolved
Install SOLAS tape or shielding on fuel system piping flanges
Due 10 May 2007
Resolved 27 April 2007
Fire Fighting › Means of Escape › Escape Route Signs
Issued 10 April 2007
Resolved
Remark emergency exits in steering room and main deck
Due 10 May 2007
Resolved 27 April 2007
Electrical › Electrical Distribution System (service) › Cable
Issued 10 April 2007
Resolved
Install metal cable mounts in engine room every 2 ft
Due 10 May 2007
Resolved 27 April 2007
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 29 June 2006
Resolved
Owner/operator of MARY FRANCES CANDIES failed to notify OCMI of unscheduled ddx iaw 46CFR 126.140 (b)
Due 29 June 2006
Resolved 29 August 2006
Electrical › Electric Supply System (service) › Cable
Issued 18 April 2006
Resolved
Install metal wire bands for engine room machinery.
Due 24 June 2006
Resolved 25 July 2006
Stability › Watertight Integrity › General
Issued 18 April 2006
Resolved
Install self closing devices on watertight forward and aft of engine room.
Action required: 705 - Other - as specified
Due 24 June 2006
Resolved 28 July 2006
Fire Fighting › Structural - A Class Divisions › Control Stations
Issued 18 April 2006
Resolved
Provide A-60 structural fire protection for CO2 room and CO2 controls.
Action required: 705 - Other - as specified
Due 24 June 2006
Resolved 25 July 2006