ACHILLES II

ACHILLES II is a 2004 freight ship. The Coast Guard has recorded 10 inspections since 2016, most recently in March 2021, along with 13 deficiencies and 4 operational controls.

Records from 2016 to 2021. Most recent: operational control imposed, 2 March 2021.

Built
2004
Last inspected
2 March 2021
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 2 March 2021
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2016–2021)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9269001
667715
Flag
PANAMA
Maury page id
psix-667715

Documentation record

Tonnage as PSIX records it38871 - Convention (Subpart B), Gross Ton
38871 - Regulatory (Subpart C or D), Gross Ton
25208 - Convention (Subpart B), Net Ton
25208 - Regulatory (Subpart C or D), Net Ton
75785 - Dead Weight, Metric Ton
85576 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 10

2 March 2021 PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7143319
2 March 2021 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7149182
7 January 2020 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6884341
24 April 2019 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6669186
13 December 2017 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6313137
27 February 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6095223
14 February 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6087890
13 February 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6090789
30 January 2017 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6071106
12 January 2016 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5790383

Deficiency record · 13

07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 2 March 2021 Resolved
MAINTENANCE, TESTING AND INSPECTIONS SHALL BE CARRIED OUT BASED ON THE GUIDELINES DEVELOPED BY THE ORGANIZATION. NO PMS COMPLETED FOR MONTH OF FEBRUARY, SPECIFICALLY FIRE EXTINGUISHERS AND SMOKE DETECTION. 74 SOLAS (14) II-2/14.2.2.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2021
Resolved 25 March 2021
Resolution: Crew completed fire extinguisher PMS for month of March as verified by attending class.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 March 2021 Resolved
INCINERATOR WALLS ARE TO BE PROTECTED WITH INSULATED FIRE BRICKS/REFRACTORY PACKING AND A COOLING SYSTEM. INSIDE OF INCINERATOR HAS EXPOSED METAL AND LACK OF REFRACTORY PACKING IN CERTAIN AREAS. PRIOR TO USE, MUST BE FIXED. MARPOL VI/16.3 MEPC. 76(40)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2021
Resolved 25 March 2021
Resolution: Crew repaired with additional refractory covering exposed areas as verified by attending class.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 2 March 2021 Resolved
THE FOLLOWING FIRE PROTECTION SYSTEMS SHALL BE KEPT IN GOOD WORKING ORDER SO AS TO ENSURE THEIR REQUIRED PERFORMANCE IF A FIRE OCCURS: FIRE DETECTION AND FIRE ALARM SYSTEMS. MULTIPLE SMOKE DETECTORS FOUND NOT IN WORKING ORDER. SEVERAL WERE REPLACED ON THE SPOT. 74 SOLAS (14) II-2/14.2.1.1.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2021
Resolved 25 March 2021
Resolution: Crew tested all E/R and house detectors finding and replacing 8 additional faulty detectors during attending class survey.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 March 2021 Resolved
THE PURPOSE OF THIS REGULATION IS TO LIMIT THE FIRE GROWTH POTENTIAL IN EVERY SPACE OF THE SHIP. THEY HAD AN ACETYLENE CYLINDER STORED WITH OXYGEN CYLINDER. SHOULD BE STOWED IAW 46 CFR 147.60. 74 SOLAS (14) II-2/5.1
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 2 March 2021
Resolved 2 March 2021
Resolution: VESSEL CORRECTED ON SPOT BY SEPARATING THE CYLINDERS TO DIFFERENT AREAS.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 2 March 2021 Resolved
FLAME DETECTORS SHALL BE TESTED ACCORDING TO STANDARDS EN 54-10:2001 AND IEC 60092-504. ALTERNATIVE TESTING STANDARDS MAY BE USED AS DETERMINED BY THE ADMINISTRATION. CREW TESTED FLAME DETECTORS WITH LIGHTER. THE LIGHT USED FOR TESTING JUST ARRIVED AFTER EXAM WAS FINISHED. 74 SOLAS (14) II-2/7.2.2 FSS 9.2.3.1.5
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 March 2021
Resolved 2 March 2021
Resolution: VESSEL RECEIVED PROPER TESTING EQUIPMENT AFTER FORM B HAD BEEN COMPLETED.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 2 March 2021 Resolved
THE STEERING GEAR COMPARTMENTS SHALL BE: PROVIDED WITH SUITABLE ARRANGEMENTS TO ENSURE WORKING ACCESS TO STEERING GEAR MACHINERY AND CONTROLS. THESE ARRANGEMENTS SHALL INCLUDE HANDRAILS AND GRATINGS OR OTHER NONSLIP SURFACES TO ENSURE SUITABLE WORKING CONDITIONS IN THE EVENT OF HYDRAULIC FLUID LEAKAGE. FLAMMABLE LIQUID CONTAINERS IN STEERING GEAR ROOM FOUND STORED ON DECK WITHOUT GRATING. CREW FOUND/MADE EXTRA GRATING. 74 SOLAS (04) II-1/29.13.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 March 2021
Resolved 2 March 2021
Resolution: CREW FOUND/MADE EXTRA GRATING.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 2 March 2021 Resolved
HYDRAULIC POWER-OPERATED STEERING GEAR SHALL BE PROVIDED WITH THE FOLLOWING: A FIXED STORAGE TANK HAVING SUFFICIENT CAPACITY TO RECHARGE AT LEAST ONE POWER ACTUATING SYSTEM INCLUDING THE RESERVOIR. THE TANK WAS FOUND AT 3/4 THE WAY TO REQUIRED FILL LEVEL. CREW FILLED TANK ON THE SPOT. 74 SOLAS (04) II-1/29.12.3
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 March 2021
Resolved 2 March 2021
Resolution: CREW FILLED TANK ON THE SPOT.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 March 2021 Resolved
IF THE VESSEL'S AUTOMATIC IDENTIFICATION SYSTEM (AIS) RADAR, RADIO NAVIGATION RECEIVERS, GYROCOMPASS, ECHO DEPTH SOUNDING DEVICE, OR PRIMARY STEERING GEAR STOPS OPERATING PROPERLY, THE PERSON DIRECTING THE MOVEMENT OF THE VESSEL MUST REPORT OR CAUSE TO BE REPORTED TO THE NEAREST CAPTAIN OF THE PORT... VESSEL DID NOT REPORT BROKEN RADAR. 33 CFR 164.53(b)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 March 2021
Resolved 2 March 2021
Resolution: VESSEL WAS COUNCILED ABOUT REPORTING REQUIREMENTS.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 2 March 2021 Resolved
MAINTENANCE OF THE SHIP AND EQUIPMENT: THE COMPANY SHOULD ESTABLISH PROCEDURES TO ENSURE THAT THE SHIP IS MAINTAINED IN CONFORMITY WITH THE PROVISIONS OF THE RELEVANT RULES AND REGULATIONS. VARIOUS PREVENTATIVE MAINTENANCE ITEMS WERE NOT COMPLETED IAW COMPANIES ISM. 74 SOLAS (IX)/3.1 ISM 10.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 March 2021
Resolved 25 March 2021
Resolution: Company conducted external audit.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 April 2019 Resolved
PSCO observed that the ship had no explosive proof or intrinsically safe radios for fire teams.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2019
Resolved 7 January 2020
Resolution: Received proper documentation showing that the radios meet requirements and are onbaord.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 13 December 2017 Resolved
Vessel had insufficient food rations in starboard lifeboat due to tears in 05 of the 25 food rations required, making them not airtight IAW with SOLAS and the LSA Code.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 December 2017
Resolution: Vessel provided the reciept and photographs of the food rations purchased and delivered to vessel.
Personnel › Certificates/Documents/Licenses › License, Chief Engineer
Issued 30 January 2017 Resolved
0220- Certificates of Competency- Any certificate required by the convention must be kept available in its original form on board the ship on which the holder is serving. During an exam of the crew licenses and endorsements it was discovered that the Chief Engineer could not provide proof of a valid license nor flag endorsement. STCW I/2 11
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 January 2017
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 30 January 2017 Resolved
9800-Other- The condition of the ship equipment shall be maintainted to conform with the provisions of the present regulation to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. The ship incinerator insulation is severely degraded with steel plating exposed endangering ships crew during normal operation. SOLAS 14 CONS. I/II (a)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 December 2017

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.