MAURY USCG vessel records
← All vessels

MSC AQUARIUS

Built
2003
Last inspected
15 May 2025
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 May 2025
…with no type recorded6
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9262704
667912
Flag
CYPRUS
Maury page id
psix-667912

Documentation record

Tonnage as PSIX records it75484 - Convention (Subpart B), Gross Ton
29555 - Convention (Subpart B), Net Ton
81171 - Dead Weight, Metric Ton
108187 - Displacement, Metric Ton
67807 - Simplified, Gross Ton
54245 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 30 inspections, each with its date, unit and type; 13 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 2 other vessels inspected with it; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

GEORGE M Towing Vessel · MISLE 1604795 · 14 April 2022 · activity 7431432WESLEY A Towing Vessel · MISLE 929544 · 10 May 2021 · activity 7194333GEORGE M Towing Vessel · MISLE 1604795 · 10 May 2021 · activity 7194333

Inspection history · 30

15 May 2025 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8136218
25 July 2024 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7966800
20 June 2024 Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7938974
10 June 2024 PSC A
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7931833
14 June 2023 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7714683
14 June 2023 Damage Survey
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7715147
14 June 2023 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7719199
11 June 2023 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7710810
29 March 2023 PSC B · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7658971
9 August 2022 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7522856
14 April 2022 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7430857
14 April 2022 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7431166
14 April 2022 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7431432
29 December 2021 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7371478
11 May 2021 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7194136
10 May 2021 In-Service Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7193937
10 May 2021 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7194333
8 May 2021 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7187249
7 October 2020 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7071537
2 October 2020 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7067489
22 July 2020 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7013309
21 July 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7011080
14 July 2020 Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7005958
14 July 2020 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7005973
16 September 2019 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6812940
18 September 2018 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6543091
3 July 2018 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6465664
8 June 2017 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6169381
3 October 2016 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6016137
22 May 2016 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5883805

Deficiency record · 13

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 June 2024 Resolved
Electrical installations shall be such that the safety of passengers, crew, and ship from electrical hazards will be ensured. Electrical dead-end cable was found on the no.1 diesel generator and is an electrical hazard. 2004 SOLAS(74) II-1/40.1.3
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2024
Resolved 20 June 2024
Resolution: Vessel provided Class Survey Report attesting to proper repairs.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 June 2024 Resolved
Main and emergency switchboards shall be so arranged as to give easy access as may be needed to apparatus and equipment batteries and chair were stored behind the emergency switchboard and arranged as to not give easy access to apparatus and equipment. 2004 SOLAS(74) II-1/45.2
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2024
Resolved 20 June 2024
Resolution: Vessel provided Class Survey Report attesting to proper repairs.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 10 June 2024 Resolved
The machinery shall be so installed and protected as to reduce to a minimum any danger to persons onboard, due regard being paid to moving parts. There was no guard on rotating equipment on the no.2 boiler water circulating pump and poses as a danger to persons onboard. 2004 SOLAS(74) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2024
Resolved 20 June 2024
Resolution: Vessel provided Class Survey Report attesting to proper repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 14 June 2023 Resolved
001-13102-The machinery shall be of a design and construction adequate for the service for which they are intended. The primary and auxiliary filter banks for main fuel supply for Ship service generators 02, 03 and 04 were blocked limiting fuel supply causing the engine to shut down; resulting in loss of ships electrical power required for ships operation and propulsion. - 74 Solas (2004 Cons.) II-1/26.1 - 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 June 2023
Resolved 15 June 2023
Resolution: Cleaned all filters to the satisfaction of class and USCG. Deficiency rectified.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 11 June 2023 Resolved
The Safety Management System (SMS) should ensure compliance with mandatory rules and regulations; and that applicable codes, guidelines and standards recommended by the Organization, Administrations, classification societies and maritime industry organizations are taken into account. The combination ofdeficiencies below indicates a serious failure, or lack of effectiveness, of the implementation of the ISM Code. A safety management audit shall be carried out by the Administration or the RO before the ship may be released from detention. 74 SOLAS (2020 Cons) IX/3.1 ISM CODE 1.2.3, 30a/c.
Action required: 30 - Ship detained
Resolved 14 June 2023
Resolution: Received class report, audit and picturces showing that the def cleared see documents for details
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 11 June 2023 Resolved
The condition of the ship shall be maintained. PSCO observed active leaks on the fuel oil purifiers and main engine fuel injectors (cylinders #2 & #8), resulting in excessive oil in the bilges throughout the engine room posing a pollution/fire risk. On March 29, 2023, the ship received a PSC exam in Houston, TX and received a similar deficiency citing excessive leakage in the engineroom. CG Sector Houston required an internal audit be completed within 90 days with "the focus on engine room maintenance and cleanliness." The required internal audit was carried out on 07Jun2023. A review of the resulting audit report by the PSCO did not reveal any particular focus on engineroom cleanliness/maintenance. Further, the excessive oil accumulation in the bilges and fuel oil purifier room constitute objective evidence that any corrective actions which may have been implemented were ineffective. 74 SOLAS (2020 Cons) IX/3.1 ISM CODE 9.2, 30a/c.
Action required: 30 - Ship detained
Resolved 14 June 2023
Resolution: Received class report, audit and picturces showing that the def cleared see documents for details
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 June 2023 Resolved
Steam pipe systems and fittings shall withstand the max working stress to which subjected. PSCO observed that lagging had been removed from fuel oil heating steam piping in the port tunnel, exposing an active steam leak and hot surfaces. Similarly, a steam leak was noted on the heat exchanger for the lube oil purifier. These conditions poses a burn risk to the crew. 74 SOLAS(2020 Cons) II-1/33.1, 30a/c.
Action required: 30 - Ship detained
Resolved 14 June 2023
Resolution: Received class report, audit and picturces showing that the def cleared see documents for details
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 June 2023 Resolved
Machinery shall be adequate for intended purpose. Excessive water leakage was noted from two scrubber seawater pumps (P01B and P01C). Multiple soft patch and unapproved repairs were also noted on the seawater scrubber piping. Finally, the sea water piping at the scrubber, located in the top of the engineroom, was leaking and raining down onto the main engine (cylinders 9-12). The excessive crystalized salt build-up on the engine head indicates long term leakage. 74 SOLAS (2020 Cons)II-1/26.1, 30a/c.
Action required: 30 - Ship detained
Resolved 14 June 2023
Resolution: Received class report, audit and picturces showing that the def cleared see documents for details
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 29 March 2023 Resolved
PRECAUTIONS SHALL BE TAKEN TO PREVENT ANY OIL THAT MAY ESCAPE UNDER PRESSURE FROM ANY PUMP, FILTER, OR HEATER FFROM COMING INTO CONTACT WITH HEATED SURFACES. PSCO OBSERVED A 5 GALLON BUCKET COMPLETELY FILLED WITH OIL UNDERNEATH THE #1 FUEL OIL TRANSFEWR PUMP, WHICH WAS ACTIVELY LEAKING AT APROX 3 TABLESPOONS PER MINUTE. ADDITIONALLY, PSCO OBSERVED NUMNEROUS PLASTIC CONTAINERS FILLED WITH OIL IN THE PURIFIER ROOM. OIL AND OILY RAGS WERE DISCOVERED THROUGHOUT THE ENGINE ROOM. 74SOLAS (01) II-2/15.4
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 March 2023
Resolution: Recieved Class Report. See attached.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 March 2023 Resolved
THE COMPANY SHOULD ESTABLISH PROCEDURES TO ENSURE THAT THE SHIP IS MAINTAINED IN CONFORMITY WITH THE PROVISIONS OF THE RELEVANT RULES AND REGULATIONS AND WITH ANY ADDITIONAL REQUIREMENTS WHICH MAY BE ESTABLISHED BY THE COMPANY. OBJECTIVE EVIDENCE DISCOVERED AS DELINEATED IN DEFICIENCY 01, THE VESSEL FAILED TO FULLY IMPLEMENT THE REQUIREMENTS OF THE SMS. AN INTERNAL AUDIT WITH THE FOCUS ON ENGINE ROOM MAINTENANCE AND CLEANLINESS IS REQUIRED WITHIN 3 MONTHS. 74SOLAS(20) IX/3.1 ISM 10.1
Action required: 705 - Other - as specified
Due 29 June 2023
Resolved 14 June 2024
Resolution: VESSEL PROVIDED DOCUMENTATION ATTESTING TO THE RECTIFICATION OF THE DEFICIENCY.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 May 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The vessel experienced a grounding while transiting the navigable waters of the United States which adversely impacted its fitness and capabilty to safely manuever the Houston Ship Channel. Submit for review a Classification Society Report to [email withheld] attesting to the cause of the equipment failure, that authorized that temporary or permanent repairs have been completed, and that the vessel's full and normal manuverability has been restored.
Action required: 60 - Rectify deficiencies prior to movement
Due 12 May 2021
Resolved 12 May 2021
Resolution: Recieved class report from RINA stating vessel was clear for service.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 16 September 2019 Resolved
THE RING, LINES AND LETTERS SHALL BE PAINTED IN WHITE OR YELLOW ON A DARK GROUND OR IN BLACK ON A LIGHT GROUND. THEY SHALL ALSO BE PERMANENTLY MARKED ON THE SIDES OF THE SHIPTO THE SATISFACTION OF THE ADMINISTRATION. THE MARKS SHALL BE PLANLY VISIBLE AND, IF NECESSARY, SPECIAL ARRANGEMENTS SHALL BE MADE FOR THIS PURPOSE. THE LOADLINE MARKINGS ON THE SHIP'S PORT SIDE WERE NOT PAINTED WHITE OR YELLOW ON A DARK BACKROUND, AND NEED TO BE PAINTED IN ORDER TO BE PLAINLY VISIBLE. ICLL 8 40AC
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 July 2020
Resolution: Received documentation from vessel stating the the load line has been fixed to the satisfaction of class society.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 September 2018 Resolved
The condition of the ship and it's equipment shall be maintained to conform to the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The bilge/heeling pump was leaking from the mechanical seal. 74SOLAS (CONS 14) I/11.a 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 18 September 2018
Resolved 22 October 2018
Resolution: recieved class report attesting to repairs.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.