Records from 2003 to 2026. Most recent: inspection, 21 May 2026.
Inspection history · 30
21 May 2026
Vessel Attendance · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8377968
5 May 2026
Vessel Attendance · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8367415
10 June 2025
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8156501
7 May 2025
Drydock Exam · Annual Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8121588
28 August 2024
Administrative Inspection · Special
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7991302
23 April 2024
Administrative Inspection · Annual Inspection · Special Consideration
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7889842
4 May 2023
Internal Structural Exam · Drydock Exam · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7679692
26 April 2022
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7439274
28 April 2021
DAPI Audit · Internal Structural Exam · Annual Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7190851
5 August 2020
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7029268
14 August 2019
Drydock Exam · Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6784486
7 May 2018
Deficiency Check · DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6403967
4 May 2018
Type not recorded
No type recorded · Station Panama City · USCG Heartland District (CGD-H) · Activity 6407644
21 February 2018
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6358685
22 May 2017
Deficiency Check · Internal Structural Exam · DAPI Audit · Hull Examination · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6147598
5 August 2016
Deficiency Check · Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5963347
28 August 2015
DAPI Audit
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5758918
29 July 2015
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5198071
20 July 2015
Deficiency Check · Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5190030
11 August 2014
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4960511
10 March 2014
Type not recorded
No type recorded · Station Panama City · USCG Heartland District (CGD-H) · Activity 4813604
23 July 2009
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3543740
17 June 2008
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3239541
12 June 2008
In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3235063
12 June 2008
Type not recorded
No type recorded · Station Panama City · USCG Heartland District (CGD-H) · Activity 3235083
28 March 2008
COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3169099
17 April 2007
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2967115
30 March 2006
Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2612534
7 March 2005
COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2304871
11 December 2003
Plan Review "T" Boat · Construction Oversight · COI Inspection · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2073247
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 May 2026
Resolved
Machinbery guard for engine to winch coupling held in place with clamps. Machinery guard to be properly secured to prevent incidental removal.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2026
Resolved 21 May 2026
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 5 May 2026
Resolved
Vessel's pre-engineered Fireboy system was accidentally discharged. System will need to be recharged/replaced and satisfactorily tested.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2026
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 May 2025
Resolved
The vessel must be equipped with Type I PFDs. There are seven (7) adult Type II PFDs that need to be replaced with Type I.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2025
Resolved 10 June 2025
Resolution: Corrected.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 23 April 2024
Resolved
Vessel's VHF/SCR radio must be programmed with vessel's GPS location.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2024
Resolved 7 May 2025
Resolution: Corrected.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 23 April 2024
Resolved
Parasail emergency procedures were not onboard.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2024
Resolved 8 May 2025
Resolution: Corrected.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 23 April 2024
Resolved
Hatches in main deck must be made watertight and have latches to keep hatch in closed position.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2024
Resolved 8 May 2025
Resolution: Corrected.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 26 April 2022
Resolved
Vessel's EPIRB battery has expired, renew or replace.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 April 2022
Resolution: New EPIRB provided.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 April 2022
Resolved
Provide proof of a valid EPIRB registration.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 April 2022
Resolution: Provided proof of EPIRB registration.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 26 April 2022
Resolved
Vessel is missing flares. Provide proof of 12 appropriate day/night flares.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 April 2022
Resolution: New flares provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 April 2022
Resolved
Provide proof of one missing adult life jacket.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 April 2022
Resolution: New life jacket provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 April 2022
Resolved
Replace worn adult life jacket.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 April 2022
Resolution: Damaged life jacket replaced.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 26 April 2022
Resolved
Proerly complete incomplete vessel maintenance and drill logs.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 April 2022
Resolution: Logs properly completed.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 26 April 2022
Resolved
Provide proof of enrollment in a drug/alcohol testing program for all crew members.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 April 2022
Resolution: Provided proof of all crew members enrollment.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 April 2022
Resolved
Prove proper operation of life ring float light.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 April 2022
Resolution: Life float light repaired and tested.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 26 April 2022
Resolved
Renew life ring light markings.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 April 2022
Resolution: Life ring markings renewed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 26 April 2022
Resolved
Repair or replace extinguished port running light.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 April 2022
Resolution: Repaired port running light.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 26 April 2022
Resolved
Provide proof of current nav publications (LL, Charts, Coast Pilot, Nav rules, Tide tables, etc)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 April 2022
Resolution: All navigational publications provided.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 April 2022
Resolved
Repair or replace broken deck hatch hinges.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 April 2022
Resolution: Hatch hinges properly secured.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 5 August 2020
Resolved
Renew EPIRB Hydro release.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 August 2020
Resolution: New Hydro installed.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 5 August 2020
Resolved
Renew Life ring light.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 August 2020
Resolution: Life ring light battery replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 August 2020
Resolved
Replace Bilge pump hose in engine room
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 August 2020
Resolution: Cracked hose replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 August 2020
Resolved
Replace sea suction hose to hydraulic oil cooler.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 August 2020
Resolution: Cracked hose replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 14 August 2019
Resolved
Provide proof of proper signal flares.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 August 2019
Resolution: New flares provided
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 August 2019
Resolved
Properly install green running light on stbd side of vessel.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 August 2019
Resolution: New green running light installed.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 14 August 2019
Resolved
Provide proof of valid radio telephony certificate. Prior to operating beyond 1000' from shore.
Action required: 705 - Other - as specified
Resolved 27 August 2019
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 14 August 2019
Resolved
Provide proof of radio operators permit. Prior to operating beyond 1000' from shore.
Action required: 705 - Other - as specified
Resolved 15 August 2019
Resolution: Operators permit provided.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 14 August 2019
Resolved
Properly post stability letter
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 August 2019
Resolution: Stability letter placed in vessel binder.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 14 August 2019
Resolved
Mount life jacket dawning placard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 August 2019
Resolution: New placard mounted.
Engineering › Bilge Water Management System › Not Operational
Issued 7 May 2018
Resolved
Repair or replace ER bilge water high level alarm.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 May 2018
Resolved 14 May 2018
Resolution: New bilge alarm installed prior to departure of MI.
Construction/Loadline › Penetrations › Gasket
Issued 7 May 2018
Resolved
Repair or replace ER hatch gasket.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 June 2018
Resolved 14 May 2018
Resolution: New gasket installed.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 7 May 2018
Resolved
Replace grab lines on life ring bouy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2018
Resolved 14 May 2018
Resolution: New grab lines placed on ring buoy.
Construction/Loadline › Structures › Superstructure
Issued 7 May 2018
Resolved
Repair crack on inflation bar port side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2018
Resolved 14 May 2018
Resolution: Satisfactory weld repair conducted.
Communications › Radio Communications › VHF Radiotelephone
Issued 14 June 2017
Resolved
Masters FCC operators license was missing
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 June 2017
Resolved 14 June 2017
Resolution: Master applied for FCC operators permit and will not operate the vessel until he recieves the FCC license.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 10 August 2016
Resolved
Provide valid COD
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 August 2016
Resolved 16 August 2016
Resolution: Vessel provided valid COD
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 10 August 2016
Resolved
Provide valid fixed fire system service report
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 August 2016
Resolved 11 August 2016
Resolution: Vessel provided report
Engineering › Bilge Water Management System › Interface Detector
Issued 10 August 2016
Resolved
Replace engine room bilge alarm
Action required: 703 - Prior to bunkering operations
Due 24 August 2016
Resolved 11 August 2016
Resolution: Vessel replaced bilge alarm
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 10 August 2016
Resolved
Replace ring buoy line
Action required: 705 - Other - as specified
Due 24 August 2016
Resolved 5 September 2016
Resolution: Vessel replaced line
Navigation › Piloting/Steering › Gyro Compass
Issued 10 August 2016
Resolved
Replace compass
Action required: 705 - Other - as specified
Due 24 August 2016
Resolved 5 September 2016
Resolution: Vessel replaced compass
Engineering › Bilge Water Management System › Not Operational
Issued 20 July 2015
Resolved
Replace Bilge pump switch.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 July 2015
Resolution: Witnessed
Engineering › Bilge Water Management System › Interface Detector
Issued 20 July 2015
Resolved
High water alarm Audible needs to be replaced FWD Compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 July 2015
Resolution: Witnessed
Stability › Watertight Integrity › General
Issued 20 July 2015
Resolved
Reattach the Deck Drain hose to the overboard discharge for the middle compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 July 2015
Resolution: Witnessed
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 20 July 2015
Resolved
Servicing reprt for the fixed system out of dated.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 July 2015
Resolution: Witnessed
Engineering › Bilge Water Management System › Valve
Issued 20 July 2015
Resolved
Modiy handle to the through hull fitting in the eng comartment STBD side.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 July 2015
Resolution: Witnessed
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 12 June 2008
Resolved
Deckhand was not enrolled in drug consortium as he was working his first day with company. Owner notified and deckhand was removed from vessel until enrollment.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 June 2008
Resolved 13 June 2008
Resolution: Owner notified and deckhand was removed from vessel until enrollment.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 12 June 2008
Resolved
Vessel's COD was invalid due to change in ownership. Must have valid COD prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 June 2008
Resolved 16 June 2008
Resolution: Vessel obtained new documentation from NVDC.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure
Issued 17 April 2007
Resolved
Recharge or replace discharged BII portable fire extinguisher
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2007
Resolution: Replaced
Construction/Loadline › Structures › Machinery Space Opening
Issued 17 April 2007
Resolved
Repair broken latch on engine hatch
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 3 May 2007
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 17 April 2007
Resolved
Properly mark life ring IAW 185.604(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (electric)
Issued 17 April 2007
Resolved
Demonstrate proper operation of MDE
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2007
Resolution: Faulty neutral safety switch
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 17 April 2007
Resolved
Demonstrate proper operation of fixed fire fighting system IAW 182.465(h)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 April 2007
Resolved
Demonstrate proper operation of running lights. IAW CLOREGS
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 3 May 2007
Engineering › Sea-water System (primary cooling) › Valve
Issued 17 April 2007
Resolved
Install closure device on MDE cooling water suction thru hull fitting IAW 176.610
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 April 2007
Engineering › Bilge Water Management System › Pump
Issued 17 April 2007
Resolved
Demonstrate visual indicators for bilge pump automatic operation IAW 182.530(g)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 3 May 2007
Construction/Loadline › Structures › Superstructure
Issued 17 April 2007
Resolved
Repair broken windshield 177.1010
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 17 May 2007
Resolved 3 May 2007
Operations/Management › Equipment Service/Testing › EPIRB
Issued 17 April 2007
Resolved
Replace EPIRB hydro release
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2007