MAURY USCG vessel records Sign in
← All vessels

BOURGEOIS TIDE

BOURGEOIS TIDE is a 2004 offshore supply vessel. The Coast Guard has recorded 13 inspections since 2004, most recently in February 2022, along with 39 deficiencies and 1 casualty investigation in 2012.

Records from 2004 to 2022. Most recent: inspection, 9 February 2022.

Built
2004
Last inspected
9 February 2022
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9273466 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
667991
Flag
VANUATU
368115000, 368166000 (licence lapsed)
Maury page id
psix-667991

Inspections, by type

…with no type recorded1
Years with a record 9 calendar years (2004–2022)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it1624 - Convention (Subpart B), Gross Ton
511 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WOACMMSI 368115000 · expired · compulsorily equipped · granted 3 September 2009, cancelled 9 November 2019
WDB6487MMSI 368166000 · cancelled · compulsorily equipped · granted 13 February 2004, cancelled 25 November 2013
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 13

9 February 2022 SIP Initial Entry
Administrative · Commandant (CG-CVC) · Activity 7393609
19 February 2016 Deficiency Check
Physical examination · Activities Europe · Activity 5818030
26 July 2012 COI Inspection · MARPOL Annex I Examination · DAPI Audit
Physical examination · Activities Europe · Activity 4387604
14 July 2012 Type not recorded
No type recorded · Activities Europe · Activity 4396465
27 April 2009 MTSA/ISPS Verification · Cargo Tank Internal · Internal Structural Exam · COI Inspection · Hull Examination
Physical examination · Activities Europe · Activity 3453565
17 June 2008 Periodic Inspection
Physical examination · Activities Europe · Activity 3243031
8 March 2007 Cargo Tank Internal · Re-Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2884131
19 May 2006 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2655971
24 January 2006 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2572270
26 October 2005 SIP Initial Entry · Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2522652
20 June 2005 Re-Inspection · Administrative Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2396384
29 March 2005 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2322560
15 April 2004 Initial Certification · Construction Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2044663

Deficiency record · 39

Engineering › Engine Controls (Electric/Electronic) › Circuit Board
Issued 26 July 2012 Resolved
Port Main Engine does not operate with bridge control.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 July 2012
Resolution: ABS report BH2181767 attesting to proper operation of port main engine.
Fire Fighting › Fire Hoses › Condition
Issued 26 July 2012 Resolved
Eight fire hoses found leaking due to broken rubber lining.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 July 2012
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 26 July 2012 Resolved
Three fire fighting outfits found on board are missing the flash hood.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 July 2012
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 26 July 2012 Resolved
Provide proof that the 24V DC ground faults on panels PP24 and SP24 are operating as intended.
Due 26 August 2012
Resolved 15 August 2012
Resolution: Rcvd email dated 15 Aug 12 from Master [name withheld] provided receipt from service tech attesting to repair of ground faults.
Engineering › Electric Propulsion System › Remote Control Circutry
Issued 26 July 2012 Resolved
Currently the keypad display, keypad and thruster indicator in the Engine Control Room are not operating as intended on both the Port and Stbd control panels. Repair to satisfaction of attending ABS surveyor.30 day extension granted at the request of the vessel Master as the vessel cannot complete the tests prior to sailing to Saudi Arabia, due date changed to 30 Oct 2012.
Action required: 705 - Other - as specified
Due 31 October 2012
Resolved 19 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 26 July 2012 Resolved
Provide proof that the Alcohol Testing strips are on board. The strips that are currently on board expired in June 2012.
Action required: 705 - Other - as specified
Due 26 August 2012
Resolved 16 August 2012
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Documentation › Logs/Records › Logbook (official)
Issued 26 July 2012 Resolved
Provide official logbook to OCMI within 90 days. Current official logbook has been in use for over 1 year.
Action required: 705 - Other - as specified
Due 26 October 2012
Resolved 15 August 2012
Resolution: Rcvd email dated 15Aug12 from Master [name withheld] that the logbook had been mailed to ACTEUR. Confirmed with IO shop that they had rcvd logbook.
Lifesaving › Rescue Boat › Propulsion Casing/Protection
Issued 26 July 2012 Resolved
Provide proof that the rescue boat engine guard has been placed on the stbd rescue boat.
Action required: 705 - Other - as specified
Due 23 September 2012
Resolved 2 September 2012
Resolution: Rcvd email dated 02 Sep 12 from [name withheld] that the propellor guard has been installed.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 26 July 2012 Resolved
Provide proof that electrical distribution panels are labeled with feeder serviced and amperage.
Action required: 705 - Other - as specified
Due 26 August 2012
Resolved 15 August 2012
Resolution: Rcvd email dated 15 Aug 12 from Master [name withheld] provided photo of proper labelling of distribution panels.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 26 July 2012 Resolved
Provide completed automation test procedures IAW approved automation plans dated 24 March 2004. 30 day extension granted at the request of the vessel Master as the vessel cannot complete the tests prior to sailing to Saudi Arabia, due date changed to 30 oct 2012.
Action required: 705 - Other - as specified
Due 31 October 2012
Resolved 19 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Construction/Loadline › Structures › Door
Issued 26 July 2012 Resolved
Watertight door indicator to be permanently affixed and operate as intended. Currently WTD indicator is held in place with two plastic ties.
Action required: 705 - Other - as specified
Due 2 August 2012
Resolved 31 July 2012
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 27 April 2009 Resolved
All lights on Lifevest out of date
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 June 2009
Resolved 3 June 2009
Resolution: inspected
Fire Fighting › Fixed CO2 Fire Extinguishing System › Remote Pulls
Issued 27 April 2009 Resolved
Pilot Nitrogen bottles on all fixed systems out of date for Hydrostatic test.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 June 2009
Resolution: inspected
Operations/Management › Drills/Instruction › Fire
Issued 27 April 2009 Resolved
Conduct man overboard and fire drills to the satisfaction of the attending coast guard marine inspector
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2009
Fire Fighting › Firemans Outfit › Self-Contained Breathing Apparatus
Issued 27 April 2009 Resolved
Have vessels SCBA bottles properly serviced and charged at a DOT approved facility or provide new bottles.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2009
Resolution: inspected
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 27 April 2009 Resolved
Hydrostatically test or renew the paint and fuel lockers fixed fire fighting bottles.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2009
Resolution: inspected
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 27 April 2009 Resolved
Have vessels fixed fire fighting system serviced in the presence of the attending coast guard marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2009
Resolution: inspected
Lifesaving › Launching Appliances › Davit
Issued 27 April 2009 Resolved
Make proper repairs to the vessels rescue boat davit and have the davit serviced IAW MSC circuliar 1206 1. Repair damaged solinoid valves 2. Renew wasted electrical boxes. 3. Provide a key to properly close the operation box cover. 4. Properly wire the davits breaker switch not to bypass the breaker.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2009
Resolution: inspected
Electrical › Electric Generation Source (service) › Ground Detection
Issued 27 April 2009 Resolved
Prove proper operation of the vessels 24V system, the system currently indicates a ground fault, on the engine room circuit breaker boxes.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2009
Resolution: inspected
Fire Fighting › Fire Hoses › Condition
Issued 27 April 2009 Resolved
Provide 4 fire hoses IAW the fire control plan.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2009
Resolution: inspected
Fire Fighting › Nozzles › Condition
Issued 27 April 2009 Resolved
Attach or provide connection chains for the all purpose nozzles. 13 not connected or missing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2009
Resolution: inspected
Fire Fighting › Ventilation Systems › Ducts
Issued 27 April 2009 Resolved
Prove proper operation of engine room supply fan fire damper for engine space.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2009
Resolution: inspected
Communications › Alarms/Indicators › General Alarm
Issued 27 April 2009 Resolved
Prove proper operation of vessels alarm system. System currently has continous alarms.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2009
Resolution: inspected
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 27 April 2009 Resolved
Prove proper operation of vessels automation system or fully man the engine space.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2009
Resolution: inspected
Operations/Management › Vessel Safety Management › Company Verification/Review/Evaluation
Issued 27 April 2009 Resolved
Perform internal ISM audit on vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2009
Resolution: Reissued
Electrical › Lighting (service) › Lighting Fixture
Issued 27 April 2009 Resolved
Renew all light fixture covers over the vessels wash basins. All of the lights need covers on top of them.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2009
Resolution: Inspected
Operations/Management › Equipment Service/Testing › EPIRB
Issued 27 April 2009 Resolved
Provide a copy of the vessels epirb regristration.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2009
Resolution: Sighted
Electrical › Electric Supply System (service) › Battery Installation
Issued 27 April 2009 Resolved
Properly stow all spare batteries in boxes.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2009
Resolution: Inspected
Lifesaving › Rescue Boat Equipment › Paddle/Oar
Issued 27 April 2009 Resolved
Provide Rescue boat oars.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2009
Resolution: Sighted
Lifesaving › Launching Appliances › Falls
Issued 27 April 2009 Resolved
End for end rescue boat davit cable or renew.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2009
Resolution: Inspected
Lifesaving › Launching Appliances › Release Mechanism
Issued 27 April 2009 Resolved
Properly attatch vessels liferafts to hydrostatic releases.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2009
Resolution: Inspected
Lifesaving › Embarkation Appliances/Stations › Steps
Issued 27 April 2009 Resolved
Provide two embarkation ladders that are the proper length.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2009
Resolution: Embarkation will be form main deck.
Lifesaving › Lifeboat Equipment › Radar Transponder
Issued 27 April 2009 Resolved
Provide a SART IAW regulations.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2009
Resolution: Inspected
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 27 April 2009 Resolved
Prove proper operation of all aircondition units installed on the vessel.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2009
Resolution: Inspected
Communications › Long Range Identification and Tracking (LRIT) › Transmission Unit
Issued 27 April 2009 Resolved
Prove proper operation of vessels gmdss system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2009
Resolution: Inspected
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 27 April 2009 Resolved
Prove proper operation of the galleys walk in cooler temp gauge.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2009
Resolution: Inspected
Navigation › Piloting/Steering › Compass Deviation Table
Issued 27 April 2009 Resolved
Supply proof of a current Deviation card. Report cleared via E-mail dated 29 Jun, Item remains open until cleared by attending Marine Inspector
Action required: 705 - Other - as specified
Due 27 July 2010
Resolved 15 June 2010
Resolution: cleared during annual inspection
Documentation › Logs/Records › Oil Record Book
Issued 27 April 2009 Resolved
Show a US oil record is onboard and being used. Report cleared via E-mail dated 29 Jun, Item remains open until cleared by attending Marine Inspector.
Action required: 705 - Other - as specified
Due 27 July 2010
Resolved 15 June 2010
Resolution: cleared during annual inspection.
Lifesaving › Inflatable Liferafts › Float Free
Issued 17 June 2008 Resolved
Prove proper installation of the 4 new life raft installations.
Due 17 August 2008
Resolved 21 July 2008
Resolution: Rcvd email and pictures confirming proper installation

Casualty record · 1

14 July 2012Routine · role: Involved in a Marine Casualty · activity 4396465
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.