Records from 2004 to 2025. Most recent: inspection, 24 June 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 34
24 June 2025
COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8165902
22 May 2025
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8117482
8 August 2024
Internal Structural Exam · Hull Examination · Deficiency Check · Annual Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7974704
23 October 2023
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7812856
17 June 2022
Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7480397
2 May 2022
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7483838
28 June 2021
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7238034
3 June 2020
Deficiency Check · Internal Structural Exam · DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6967322
13 May 2020
Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6952470
1 October 2019
Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6825798
11 July 2018
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6475283
7 June 2018
Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6436812
26 April 2018
Internal Structural Exam · Drydock Extension
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6400766
10 August 2017
Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6226235
5 July 2017
Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6198400
13 October 2016
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6020152
27 June 2016
Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5921658
16 July 2015
Deficiency Check · Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5138223
15 October 2014
Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5001500
14 May 2014
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 4858418
9 May 2014
Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 4854437
4 August 2011
Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 4105188
11 March 2010
COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3694573
6 January 2009
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3389616
12 August 2008
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3289823
15 July 2008
Hull Examination · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3252883
27 July 2007
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3012283
18 April 2006
Internal Structural Exam · Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2627163
25 October 2005
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2521780
4 October 2005
Plan Review "T" Boat
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 2507516
26 September 2005
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2501378
3 August 2005
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2450409
18 January 2005
Administrative Inspection
Administrative · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2276553
19 March 2004
COI Inspection · Initial Construction-Excluding Oversight · Initial Certification
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2027636
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 September 2024
Resolved
Provide limited QFA for new installed engine controls and bow thruster collector joystick controller.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 9 September 2024
Resolved 24 October 2024
Resolution: Completed letter provided.
05 - Radio Communications › N/A - No Subsystem › Performance standards for radio equipment
Issued 6 September 2024
Resolved
Provide FCC Safety and Bridge to Bridge certificates.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2024
Resolved 24 October 2024
Resolution: FCC Station and Bridge to bridge renewed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 8 August 2024
Resolved
through hull valve for the fire main system was beyond servicable condition. The internals had corroded and the valave would not seal when closed.
Action required: 705 - Other - as specified
Due 8 August 2024
Resolved 2 September 2024
Resolution: Vessel had new valve installed by Billings Marine and Diesel.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 8 August 2024
Resolved
Port fuel tank vent pipe has corroded and is missing a piece of the vent, making a large hole above the vent screen.
Action required: 705 - Other - as specified
Due 8 August 2024
Resolved 2 September 2024
Resolution: Vessel has a new fuel tank vent (goose neck) installed on the port side.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 8 August 2024
Resolved
High water alarm audio inop.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2024
Resolved 24 October 2024
Resolution: Alarm fixed and test sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 23 October 2023
Resolved
Vessel must undergo an annual inspection as specified in paragraph (b)(1) of this section. Vessel must undergo an annual inspection within 3 months before or after the each anniversary date. Vessels anniversary date was 02Jul23, and vessel is past 3 months from said date.
Vessel shall not operate with passengers until an annual inspection has been complete.
46 CFR 176.500(b)
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 October 2023
Resolved 23 October 2023
Resolution: completed annual inspecion.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2023
Resolved
(b) All equipment, including switches, fuses, lampholders, etc., must be suitable for the voltage and current utilized. (d) All electrical equipment and circuits must be clearly marked and identified.
During the time of inspection the 12v distribution panel had multiple breakers that did not match their identifying labeling. A 40Amp breaker was put in the place of a 15amp, and a 20amp was in the place of a 15amp. Number 12 breaker on the panel did not have a amperage labeling.
46 CFR 183.220(b)
46 CFR 183.220(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2023
Resolved 1 November 2023
Resolution: Vessel POC sent pictures rectifying the deficiency
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 October 2023
Resolved
Each ring life buoy on a vessel must: (1) Be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150.
During the time of inspection one of the 3 liferings had no identifying information on it from the manufacturer. The plug for the lifering was also missing with evidence of water intrusion into the ring making it heavier than designed.
46 CFR 180.70(b)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2023
Resolved 1 November 2023
Resolution: Vessel POC sent pictures rectifying the deficiency
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 July 2020
Resolved
Replace leaking 50ft, 1 1/2 in fire hose.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2020
Resolved 17 August 2020
Resolution: New fire hose installed on vessel.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 15 July 2020
Resolved
Provide DOT approved ALCO II alco test strips.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2020
Resolved 17 August 2020
Resolution: New ALCO II test installed on vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 July 2020
Resolved
Provide cover for exposed wiring on port wiper assembly.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2020
Resolved 17 August 2020
Resolution: New cover manufactured and installed on wiper assembly.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 15 July 2020
Resolved
Provide / replace expired meds for first aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2020
Resolved 17 August 2020
Resolution: New Meds supplied to first aid kit.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 2 October 2019
Resolved
Provide aspirin for first aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 November 2019
Resolved 16 October 2019
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 2 October 2019
Resolved
Replace COD holder (Broken Glass).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 November 2019
Resolved 16 October 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 2 October 2019
Resolved
Locate and post cover page of COI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 November 2019
Resolved 16 October 2019
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 2 October 2019
Resolved
Log monthly safety equipment checks.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 November 2019
Resolved 16 October 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 2 October 2019
Resolved
Provide FCC Safety and Bridge to Bridge certificates.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 November 2019
Resolved 25 November 2019
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 2 October 2019
Resolved
Replace EPIRB HRU. Vessel restricted to NMT 3 miles from land until corrected.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 October 2019
Resolved 16 October 2019
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 2 October 2019
Resolved
Replace EPIRB battery. Vessel restricted to NMT 3 miles from land until corrected.
Action required: 705 - Other - as specified
Due 2 November 2019
Resolved 16 October 2019
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 2 October 2019
Resolved
Repair intermittent fault in stern light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 November 2019
Resolved 16 October 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 October 2019
Resolved
Replace ring buoy.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 November 2019
Resolved 16 October 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 October 2019
Resolved
Address fuel leak on starboard MDE.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2019
Resolved 16 October 2019
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 1 October 2019
Resolved
Provide 4 additional red flares or orange smokes. Vessel restricted to LBS until corrected.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 November 2019
Resolved 16 October 2019
Construction/Loadline › Penetrations › Valve Flange
Issued 7 June 2018
Resolved
(06) Sea valves located at the load waterline were found inoperable preventing valves from being closed. Service valves and prove operation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2018
Resolved 2 July 2018
Lifesaving › Inflatable Buoyant Apparatus › Quantity
Issued 5 July 2017
Resolved
IBAs were removed for servicing; vls restricted to within 3nm on a LCW route unitl IBAs are re-installed and examined by a MI.
Action required: 705 - Other - as specified
Due 5 August 2017
Resolved 10 August 2017
Resolution: IBA's have been serviced and installed in presence of Marine inspector.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure Gauge
Issued 13 October 2016
Resolved
The BII extinguisher in the galley was low on the gauge, vls to replace with a similar size & type.
Action required: 705 - Other - as specified
Due 13 November 2016
Resolved 14 November 2016
Resolution: A new BII extinguisher was placed in the galley.
Fire Fighting › Fire Pumps › Pressure
Issued 13 October 2016
Resolved
Replace the pressure gauge for the fire pump.
Action required: 705 - Other - as specified
Due 13 November 2016
Resolved 14 November 2016
Resolution: Pressure gauge replaced and working.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 13 October 2016
Resolved
Affix the vsl's name to the bow, P/S.
Action required: 705 - Other - as specified
Due 13 November 2016
Resolved 14 November 2016
Resolution: Markings were installed on the vsl's bow, all SAT.
Lifesaving › Inflatable Buoyant Apparatus › Not on Board
Issued 27 June 2016
Resolved
Vessel restricted to Lakes, Bays, and Sounds not more than 1 mile from shore until IBAs are serviced and reinstalled on the vessel.
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 19 July 2016
Resolution: IBAs back on board.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 16 July 2015
Resolved
Provide proposal to repair or replace black water tank (pitted).
Action required: 705 - Other - as specified
Due 16 August 2015
Resolved 5 October 2015
Resolution: Attended vessel. Tank is repaired.
Electrical › Lighting (service) › Lighting Fixture
Issued 16 July 2015
Resolved
Prove operation of all overhead lighting in accomodation spaces and engine room.
Action required: 705 - Other - as specified
Due 20 July 2015
Resolved 17 July 2015
Resolution: Lights have been replaced.
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 16 July 2015
Resolved
Install currently serviced IBAs on board. Vessel is restricted from operating not more than 3 miles from land on a limited coastwise route until cleared.
Action required: 705 - Other - as specified
Due 1 October 2015
Resolved 5 October 2015
Resolution: Attended vessel. Confirmed that IBAs are installed.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 15 October 2014
Resolved
Provide FCC Bridge to Bridge Certificate
Action required: 705 - Other - as specified
Due 31 January 2015
Resolved 28 January 2015
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 15 October 2014
Resolved
Repair missing rail aft deck, stbd side.
Action required: 705 - Other - as specified
Due 15 November 2014
Resolved 13 November 2014
Resolution: [name withheld] notified MSD that rail is repaired.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 15 October 2014
Resolved
Provide hydrostatic testing of CO2 cylinders.
Action required: 705 - Other - as specified
Due 31 January 2015
Resolved 28 January 2015
Electrical › Electric Supply System (service) › Battery Installation
Issued 4 August 2011
Resolved
Remove stagnant water from battery containment boxes.
Condition: Design Flaw
Due 1 September 2011
Resolved 25 August 2011
Engineering › Feedwater/Condensate Water System › Pump
Issued 4 August 2011
Resolved
Repair seal on generator raw water pump.
Condition: Improper Installation
Due 1 September 2011
Resolved 29 September 2011
Lifesaving › Buoyant Apparatus › Marking
Issued 4 August 2011
Resolved
Stencil updated vsl name on hull & Lifesaving equipment.
Condition: Improper Installation
Due 1 September 2011
Resolved 25 August 2011
Documentation › Certificates/Documents › FCC SSL
Issued 4 August 2011
Resolved
Provide valid FCC safety certificate.
Condition: Invalid
Due 1 September 2011
Resolved 25 August 2011
Operations/Management › Equipment Service/Testing › EPIRB
Issued 4 August 2011
Resolved
Provide valid hydrostatic unit for EPIRB
Condition: Improper/Lack of Maintenance
Due 1 September 2011
Resolved 25 August 2011
Documentation › Logs/Records › Drug Test Records
Issued 12 August 2008
Resolved
PROVIDE PROOF OF CURRENT DRUG AND ALCOHOL PROGRAM AUDIT PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 January 2009
Resolution: PROVIDED PROOF OF CURRENT DRUG AND ALCOHOL PROGRAM AUDIT.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 12 August 2008
Resolved
PROVIDE PROOF OF CURRENT FIRE EXTINGUISHER SERVICE PRIOR TO CARRYING PASSENGERS.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 January 2009
Resolution: PROVIDED PROOF OF CURRENT FIRE EXTINGUISHER SERVICE.
Lifesaving › Launching Appliances › Release Mechanism
Issued 12 August 2008
Resolved
PROVIDE PROOF OF CURRENT HYDROSTATIC RELEASE TEST FOR EPIRB PRIOR TO CARRYING PASSENGERS.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 January 2009
Resolution: PROVIDED PROOF OF CURRENT HYDROSTATIC RELEASE TEST FOR EPIRB.
Navigation › Collision/Grounding Avoidance › Radar
Issued 12 August 2008
Resolved
PROVIDE PROOF OF OPERATING RADAR/ RADAR OOC PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 January 2009
Resolution: PROVIDED PROOF OF OPERATING RADAR/ RADAR OOC.
Personnel › Training › Fire Fighting Basic
Issued 12 August 2008
Resolved
PERFORM MAN OVERBOARD DRILL TO THE SATISFACTION OF MARINE INSPECTOR PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 January 2009
Resolution: PERFORMED MAN OVERBOARD DRILL TO THE SATISFACTION OF MARINE INSPECTION.
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 12 August 2008
Resolved
PROVIDE CURRENT FCC MARINE OPERATOR PERMIT IAW 47CFR80 PRIOR TO CARRYING PASSENGERS.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 January 2009
Resolution: PROVIDED CURRENT FCC MARINE OPERATOR PERMIT IAW 47CFR80.
Engineering › Bilge Water Management System › Pump
Issued 3 August 2005
Resolved
Install a bilge pump that uses a seperate power supply from the STBD main engine (46 CFR 182.520(d).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 September 2005
Resolved 23 September 2005
Engineering › Steering Gear System › Feedback Unit
Issued 3 August 2005
Resolved
Provide limit switches in accordance with 46 CFR 182.610(f)(5).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 October 2005
Resolved 24 October 2005