Records from 2016 to 2025. Most recent: inspection, 16 May 2025.
Inspection history · 14
16 May 2025
Deficiency Check · Hull Examination · Internal Structural Exam · Administrative Inspection · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8137460
20 December 2023
Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7844647
28 August 2023
Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7780374
15 June 2023
Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7715760
8 September 2022
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7554070
11 August 2021
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7270831
23 March 2021
Internal Structural Exam · Hull Examination · Plan Review "T" Boat
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7149155
4 June 2020
Deficiency Check · Annual Inspection · Drydock Extension
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6965370
20 May 2019
Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6688382
8 May 2018
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6409190
28 November 2017
Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6314087
1 September 2017
Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6257031
19 July 2016
Spot Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5946132
7 June 2016
Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5902421
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 June 2025
Resolved
3 Fire buckets and labeled " FIRE BUCKETS" need to be on board. Missing fire buckets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2025
Resolved 16 July 2025
Resolution: 3 fire buckets onboard vessel and labelled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 June 2025
Resolved
Provide proper tools for emergency steering operation. No way to disconnect the steering ram for an emergency steering systems.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2025
Resolved 16 July 2025
Resolution: Proper tools onboard to set up emergency steering.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 24 June 2025
Resolved
Updated first aid kit with required items. CG will provide updated list to vessel operator.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2025
Resolved 16 July 2025
Resolution: First aid kit has required items.
10 - Safety of Navigation › N/A - No Subsystem › Gyro compass
Issued 24 June 2025
Resolved
Compass needs to be onboard for navigation. Compass missing
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2025
Resolved 25 June 2025
Resolution: New compass has been installed.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 28 August 2023
Resolved
A person may not employ or engage an individual unless the individual is serving in a capacity within their MMC, including any restrictions placed on the MMC. The operator during the inspection did not have the correct endorsement to allow operating in the waters where the vessel operates. Correct license prior to operating vessel outside of limiting area.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 5 December 2023
Resolution: Launch operator is no longer employed by marina.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 28 August 2023
Resolved
The construction of a vessel must allow the safe operation, including a seaworthy hull. There are two lights in the bow that are not watertight.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2023
Resolved 5 December 2023
Resolution: Sealed lights
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 August 2023
Resolved
A vessel of not more than 26 feet must have at least one ring life buoy. The ring life buoy was in poor condition and unservicible.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2023
Resolved 5 December 2023
Resolution: Replaced lifering
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 August 2023
Resolved
Provide state registration for vessel. During inspection, operator could not provide valid state registration.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2023
Resolved 5 December 2023
Resolution: O/o provided registration
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 23 June 2020
Resolved
Required 10-B:C at the operating station. Vessel had a 5-B:C plastic ext that was recalled and not serviceable by Fire system company.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2020
Resolved 26 June 2020
Resolution: Vessel got the required fire ext and it was serviced by a certified company.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 June 2020
Resolved
Vessel needs to demonstrate proper operation main propulsion. Main engine could not start after Fire Boy overide test.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 23 July 2020
Resolved 26 June 2020
Resolution: Vessel rep sent video of the boat underway maneuvering.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 23 June 2020
Resolved
Vessel required to have medical kit as per 160.041 required container and contents. Vessel had a smaller scaled version that does not meet the regulation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2020
Resolved 23 July 2020
Resolution: Vessel rep provided evidence of correct medical equipment onboard.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 1 September 2017
Resolved
Renew expired items in first aid kit.
Due 1 October 2017
Resolved 29 September 2017
Resolution: Items renewed.
Fire Fighting › Fire Bucket › Availability
Issued 1 September 2017
Resolved
Provide third fire bucket.
Due 1 October 2017
Resolved 29 September 2017
Resolution: Bucket provided.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 1 September 2017
Resolved
Provide new bracket for portable fire extinguisher.
Due 1 October 2017
Resolved 29 September 2017
Resolution: Bracket provided.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 7 June 2016
Resolved
Inspect and install safety tab on fire pin at pull station.
Condition: Improper/Lack of Maintenance
Due 14 June 2016
Resolved 10 June 2016
Resolution: Fire tab removed and replaced.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 7 June 2016
Resolved
Provide pre-employment drug test for all operators.
Due 10 June 2016
Resolved 13 June 2016
Resolution: Received docments that all crew members have been tested.