Records from 2016 to 2026. Most recent: inspection, 9 April 2026.
Inspection history · 14
9 April 2026
Deficiency Check · Administrative Inspection · Vessel Attendance · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8373999
12 February 2026
Plan Review "T" Boat · Construction Oversight
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8330890
22 April 2025
Annual Inspection · Internal Structural Exam · Deficiency Check · Drydock Exam · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8110296
6 May 2024
COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7899952
9 May 2023
Drydock Exam · Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7677438
11 April 2022
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7422961
4 May 2021
Annual Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7178870
13 April 2020
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6935951
2 May 2019
Internal Structural Exam · COI Inspection · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6667840
30 April 2018
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 6420072
8 February 2018
Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6385289
28 April 2017
Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6128756
28 April 2017
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 6137241
28 April 2016
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 5864066
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 April 2026
Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. Provide a cover for the 2 terminal blocks inside the fwd void.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2026
Resolved 21 July 2026
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 April 2026
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards. Place a cover on the open light housing inside the fwd void.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2026
Resolved 21 July 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 April 2026
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Renew the grabline on the lifebuoy and 3-6ft line on the floating waterlight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2026
Resolved 23 July 2026
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 April 2025
Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels who occupy a position required by the vessel's Certificate of Inspection. Vessel is not currently enrolled in a chemical testing program. Provide proof of enrollment and chemical testing for crewmembers.
46 CFR 16.230
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2025
Resolution: Provided proof of enrollment and testing. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 April 2025
Resolved
Propulsion machinery must be installed and capable of operating at constant marine load. Vessel's electronic engine control module in the engine compartment is broken loose from the main engine. Provide permanent means of securing the module to the engine to prevent subsequent damage or loss of propulsion to the satisfaction of the attending USCG marine inspector. 46 CFR 182.200
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2025
Resolution: ECM permanently secured with metal bracket.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 April 2025
Resolved
A pre-engineered fixed gas fire extinguishing system must automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. Vessel was unable to test the Fixed extinguishing system shutdown and manual override. Cond-
duct crew training and demonstrate proper test procedure
to the satisfaction of the attending CG marine inspector
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2025
Resolution: Fixed FES tested satisfactorily.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 9 May 2023
Resolved
A vessel must carry an approved first-aid kit in a suitable, watertight container that is marked "First-Aid Kit" and made easily visible and available to the crew. Vessel's pre-packaged Orion first-aid kit expired in 2022. Install a serviceable first-aid kit that meets the criteria of ISO 18813 (see Federal Register Vol. 87, No. 218).
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2023
Resolved 17 May 2023
Resolution: Operator submitted photos of satisfactory correction.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 9 May 2023
Resolved
A vessel on a Lakes, Bays, & Sounds route must carry 3 hand red flare distress signals and 3 orange smoke distress signals (or 6 total red flare distress signals) in a portable watertight container carried at the operating station. All 6 distress signals were expired upon inspection. Install 6 distress signals with valid expiration dates.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2023
Resolved 17 May 2023
Resolution: Operator submitted photos of satisfactory correction.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 May 2023
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in a conspicuous place that is regularly accessible to the crew and passengers. The existent placard aboard the vessel was sun-bleached and illegible to crew and passengers. Replace current placard with a legible piece, taking into account the type of life jackets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2023
Resolved 17 May 2023
Resolution: Operator submitted photos of satisfactory correction.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 4 May 2021
Resolved
A VISUAL AND AUDIBLE ALARM MUST BE INSTALLED AT THE OPERATING STATION TO INDICATE HIGH WATER LEVEL IN THE BILGE. THE HIGH LEVEL BILGE ALARM "VISUAL LIGHT" WAS NOT OPERATIONAL, AUDIBLE WAS OPERATIONAL.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2021
Resolved 14 May 2021
Resolution: wittnessed operation via facetime.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 4 May 2021
Resolved
EACH VESSEL SHALL BE EQUIPPED WITH TWO PORTABLE BATTERY OPERATED LIGHTS, ONE AT OPERATOR STATION, AND ONE AT MACHINERY SPACE. VESSEL DID NOT HAVE TWO PORTABLE LIGHTS.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2021
Resolved 14 May 2021
Resolution: wittness onboard and operational via facetime.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 15 April 2020
Resolved
Flares were expired, renew flares.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 April 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 April 2018
Resolved
The fuel shutoff valve for the fuel tank was plastic. Replace valve shutoff.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2018
Resolved 10 July 2018
Resolution: Replaced fuel shutoff valve.