MAURY USCG vessel records
← All vessels

BACK ACHE

BACK ACHE is a 2003 passenger vessel (inspected). The Coast Guard has recorded 12 inspections since 2016, most recently in April 2026, along with 24 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 2 April 2026.

Built
2003
Last inspected
2 April 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 2 April 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDJ3690
668713
Flag
UNITED STATES
Maury page id
psix-668713

Documentation record

Tonnage as PSIX records it1 - Simplified, Gross Ton
1 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 12

2 April 2026 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8319888
31 March 2025 Hull Examination · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8100467
23 April 2024 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7899895
8 March 2023 Annual Inspection · Hull Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7659215
13 April 2022 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7418683
31 March 2021 COI Inspection · Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7153374
1 June 2020 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6968637
17 March 2020 Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6921157
11 April 2019 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6648426
4 April 2018 Hull Examination · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6375825
12 April 2017 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6099546
4 April 2016 Hull Examination · COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5837931

Deficiency record · 24

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 31 March 2025 Resolved
Vessels less than 26ft are required to have one portable hand pump capable of pumping water, but not necessarily simultaneously, from all watertight compartments. Body of hand pump was cracked. Replace hand pump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2025
Resolved 7 April 2025
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 31 March 2025 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. On board kit was not watertight and had expired items. Replace kit IAW requirements.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2025
Resolved 7 April 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 31 March 2025 Resolved
The weather deck on a well deck vessel must be watertight. STBD scupper was missing device to prevent backflow of water into vessel. replace scupper with in-kind equipment.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2025
Resolved 7 April 2025
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 31 March 2025 Resolved
All agreements and arrangements, written or unwritten, between and among employers and service agents concerning the implementation of DOT drug testing requirements are deemed, as a matter of law, to require compliance with all applicable provisions of this part and DOT agency drug testing regulations. Vessel consortium list and test were expired. Provide valid list and testing strips to marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2025
Resolved 7 April 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 March 2023 Resolved
Over-current protection must be provided for each ungrounded conductor and fuses must be of the cartridge type only and be listed by Underwriters Laboratories or another independent laboratory recognized by the Commandant. Remove blade type fuse currently using for jack plate power supply and provide proper over current protection.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2023
Resolved 30 April 2023
Resolution: Blade style fuse removed and new breaker installed
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 30 March 2023 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Aspirin is expired. Renew in kind.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2023
Resolved 30 April 2023
Resolution: Aspirin was renewed.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 30 March 2023 Resolved
Crew training shall be logged or otherwise documented for review by the Coast Guard upon request. The training entry shall include the following information. (1) Date of the training; and (2) General description of the training topics. Properly log drills and provide documentation to the Marine Inspector
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2023
Resolved 30 April 2023
Resolution: Drills were conducted and properly logged in the vessel deck log.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 13 April 2022 Resolved
No vessel will be navigated unless its under the direction and control of an individual who holds a MMC. Master did not have MMC on board. Conducted training with the master.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 April 2022
Resolution: Master presented original MMC prior to departure.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 13 April 2022 Resolved
A vessel must comply with the applicable requirements issued by the FCC. Vessel did not have VHF radio integrated with GPS or MMSI number. Install radion that is capable of requirement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2022
Resolved 15 April 2022
Resolution: VHF radio is onboard the vessel with integrated with GPS and MMSI number. Radio check conducted IAW MSIB 20-20
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 13 April 2022 Resolved
No marine employer shall engage or employ and individual to serve as crewmember unless they pass a chemical test. Provide pre-employment drug testing results and implement drug and alochol program on board.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 April 2022
Resolution: Valid Drug and alcohol program is now onboard the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 13 April 2022 Resolved
Type I retroreflective material must be capable of being attached to lifesavings material. Install new retro tape to 01 adult life jacket.
Action required: 705 - Other - as specified
Due 20 April 2022
Resolved 15 April 2022
Resolution: Retro-reflective tape installed on all selected PFD's
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 13 April 2022 Resolved
A COI must be kept onboard in a weatheright container. Provide proof container is onboard.
Action required: 705 - Other - as specified
Due 20 April 2022
Resolved 15 April 2022
Resolution: Watertight is onboard the vessel for COI and stability instead of posting under glass.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 31 March 2021 Resolved
Provide alcohol test strips onboard
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2021
Resolved 2 April 2021
Resolution: Test strips on board
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 31 March 2021 Resolved
Provide updated marine charts for vessel operating area.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2021
Resolved 2 April 2021
Resolution: Updated charts are now onboard the vessel for operating area.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 31 March 2021 Resolved
Provide required navigational pubs onboard; coast pilot, light list, navigational rules.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2021
Resolved 2 April 2021
Resolution: All navigational pubs on board.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 31 March 2021 Resolved
Renew all fuel hoses
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2021
Resolved 2 April 2021
Resolution: Fuel hoses were renewed and properly installed.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 31 March 2021 Resolved
Replace all hose clamps.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2021
Resolved 2 April 2021
Resolution: Clamps were replaced with new.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 March 2021 Resolved
Life ring was found un-serviceable and must be renewed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2021
Resolved 2 April 2021
Resolution: Life ring was renewed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 31 March 2021 Resolved
Properly secure all cleats
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2021
Resolved 2 April 2021
Resolution: Cleats were properly tightened
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 31 March 2021 Resolved
Install additional course rail at the port and starboard embarkation points.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2021
Resolved 2 April 2021
Resolution: Additional rail course was installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 June 2020 Resolved
2 child and 5 audult life jackets found to be sun damaged and need to be replace as per video provided by owner.
Action required: 10 - Deficiency Rectified
Resolved 1 June 2020
Resolution: New lifejackets on the vessel with proper marking.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 1 June 2020 Resolved
FIrst aid kit not approved as per video provided by owner operator.
Action required: 10 - Deficiency Rectified
Resolved 1 June 2020
Resolution: New approved kits installed on vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 March 2020 Resolved
Which conducting review of photos it was noted that a plastic fuel filter was installed. Change to metal bowl.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 April 2020
Resolution: New fuel filter installed with metal bowl.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 April 2019 Resolved
Repair fractures IWO canopy top.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2019
Resolved 30 March 2020
Resolution: Cleared using objective evidence photos. (COVID-19)

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.