MAURY USCG vessel records Sign in
← All vessels

FRIENDS GOOD WILL

FRIENDS GOOD WILL is a 2004 passenger vessel (inspected). The Coast Guard has recorded 45 inspections since 2004, most recently in August 2026, along with 22 deficiencies and 8 casualty investigations between 2005 and 2017.

Records from 2004 to 2026. Most recent: inspection, 5 August 2026.

Built
2004
Last inspected
5 August 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC4005
668869
Flag
UNITED STATES
367017720
Maury page id
psix-668869

Inspections, by type

…with no type recorded3
Years with a record 20 calendar years (2004–2026)
The 45 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)56.5 ft × 17.0 ft × 11.3 ft
Registered tonnagegross 54 / net 48
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSCARANO BOAT BUILDING INC · ALBANY, NY, UNITED STATES · built 2004
Hull materialWood
PropulsionDiesel Direct
Hull shapeSail (Distinct Keel)
Hull configurationMonohull
Hailing portSOUTH HAVEN, MI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 30 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it54 - Simplified, Gross Ton
44 - Displacement, Gross Ton
51 - Dead Weight, Gross Ton
48 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDR4165MMSI 367017720 · active · compulsorily equipped · granted 5 September 2026, expires 5 September 2036
WDC4005MMSI 367017720 · expired · compulsorily equipped · granted 2 February 2015, cancelled 19 April 2025
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 45

5 August 2026 Administrative Inspection
Administrative · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 8449478
18 August 2025 Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 8194376
22 May 2024 COI Inspection
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7915555
11 December 2023 Administrative Inspection
Administrative · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7837577
7 June 2023 Annual Inspection
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7706271
8 November 2022 Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7591367
24 May 2022 Annual Inspection
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7479576
27 April 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 7457254
27 July 2021 Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7269718
24 June 2020 Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 6985735
26 September 2019 In-Service Inspection
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 6822588
5 June 2019 COI Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6682865
9 January 2019 Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6624724
16 August 2018 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6538370
30 April 2018 Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6559550
26 January 2018 Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6559535
1 December 2017 Examination of Repairs
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 6340349
29 August 2017 DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 6253924
17 July 2017 Deficiency Check
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 6212607
7 June 2017 Type not recorded
No type recorded · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 6168759
6 June 2017 Internal Structural Exam · Drydock Exam
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 6169512
1 February 2017 Examination of Repairs · Administrative Inspection
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 6089525
8 September 2016 In-Service Inspection
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 5996373
3 September 2016 Type not recorded
No type recorded · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 5993399
28 July 2016 Attraction Vessel Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5955606
9 June 2016 Annual Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 5925850
5 June 2014 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 4885956
4 March 2014 Examination of Repairs
Physical examination · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 4810181
9 September 2011 Attraction Vessel Exam
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4151025
9 August 2011 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4116134
21 July 2011 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4088997
4 March 2010 COI Inspection
Physical examination · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 3704585
2 February 2010 Examination of Repairs
Physical examination · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 3674966
29 April 2009 Deficiency Check · Annual Inspection
Physical examination · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 3517991
29 October 2008 Drydock Exam
Physical examination · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 3360519
6 May 2008 Annual Inspection
Physical examination · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 3204860
18 December 2007 Administrative Inspection
Administrative · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 3118029
8 May 2007 Annual Inspection
Physical examination · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2927737
25 May 2006 Deficiency Check
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2658861
24 April 2006 Annual Inspection
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2632369
4 April 2006 Administrative Inspection
Administrative · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2616724
8 July 2005 Damage Survey · Deficiency Check
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2420067
8 July 2005 Type not recorded
No type recorded · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2420079
1 February 2005 Administrative Inspection · Initial Certification
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2284347
12 February 2004 Initial Construction-Excluding Oversight · Administrative Inspection · Hull Examination · Simplified Stability Test · Internal Structural Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2005320

Deficiency record · 22

01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 August 2025 Resolved
Vessel must comply with FCC requirements that are applicable. Vessel had an expired FCC Station License.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 September 2025
Resolved 4 September 2025
Resolution: Received valid FCC Station License
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 24 May 2022 Resolved
Hydrostatic release on 01 of 02 liferafts was installed improperly.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 24 May 2022
Resolved 24 May 2022
Resolution: Crew properly attached hydrostatic release prior to the conclusion of the inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 April 2022 Resolved
Propeller hub fasteners found to be loose/missing. Replace as original and lock securely.
Action required: 60 - Rectify deficiencies prior to movement
Due 6 May 2022
Resolved 3 May 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 April 2022 Resolved
Exhaust elbow insulation is deteriorated. Renew as original.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2022
Resolved 21 June 2022
Resolution: Renewed exhaust blanket
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 16 August 2018 Resolved
Vessel is required 06 hand red and 06 hand orange flares. Vessel only had four each.
Due 24 August 2018
Resolved 17 August 2018
Construction/Loadline › Hull › Strut/Cross Tie
Issued 6 June 2017 Resolved
King/Samson post cracked at upper port section in forpeak.
Action required: 705 - Other - as specified
Due 8 July 2017
Resolved 29 August 2017
Resolution: Checked area was epoxied and repaired, DDGH
Construction/Loadline › Hull › Hull Plating
Issued 6 June 2017 Resolved
Unable to observe interior hull approximately six feet aft and two feet down from the vessel transducer on the starboard side.
Action required: 705 - Other - as specified
Due 7 July 2017
Resolved 17 July 2017
Resolution: Area made avaiable for inspecion.
Electrical › Electric Supply System (service) › Battery Charger
Issued 8 September 2016 Resolved
Battery Charger does not have an ammeter in the charging circuit.
Action required: 705 - Other - as specified
Due 8 October 2016
Resolved 29 August 2017
Resolution: Ammenter installed, DDGH
Electrical › Electric Generation Source (emergency) › Circuit Breaker
Issued 8 September 2016 Resolved
Unable to demonstrate using emergency battery start.
Action required: 705 - Other - as specified
Due 9 October 2016
Resolved 29 August 2017
Resolution: E battery start demonstrated, DDGH
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 September 2016 Resolved
Alterations were made to the electrical system with no plans submitted to the OCMI
Due 8 October 2016
Resolved 29 August 2017
Resolution: Plans submitted, DDGH
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 September 2016 Resolved
Shore tie had possible split in outer covering.
Due 8 October 2016
Resolved 29 August 2017
Resolution: Shore tie repaired, DDGH
Electrical › Lighting (emergency) › Lighting Fixture
Issued 9 June 2016 Resolved
Automatic battery operated "E" lights did not energize upon loss of 24VDC system.
Due 21 July 2016
Resolved 29 August 2017
Resolution: E lights, repaired, DDGH
Sail Rigging › Spars › Boom and Gooseneck Fitting
Issued 4 March 2014 Resolved
Complete repairs to crossjack yard and dolphin striker, and have inspected by Coast Guard Marine Inspector prior to painting/coating
Action required: 705 - Other - as specified
Due 30 April 2014
Resolved 5 June 2014
Resolution: Spars repaired by gouging affected areas and inserted with wooden stips and epoxy. Additional circumfrential straps applied for added protection.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 29 April 2009 Resolved
Install emergency lighting in accommodation deck IAW 46 CFR 183.430. Vessel is restricted from carrying overnight passengers or crew until properly installed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 12 June 2009
Resolution: Verified proper operation and installation of emergency lighting in required spaces.
Communications › Radio Communications › VHF Radiotelephone
Issued 29 April 2009 Resolved
At least one deck hand must carry a valid Marine Radio Operator Permit if master does not, IAW 47 CFR 180. 161.
Action required: 705 - Other - as specified
Due 29 May 2009
Resolved 29 May 2009
Resolution: Received copy of masters Marine Radio Operator Permit.
Engineering › Bilge Water Management System › Interface Detector
Issued 6 May 2008 Resolved
Relocate bilge high level alarm even in high with the bilge pump actuator IAW 46 CFR 182.530 (c).
Action required: 705 - Other - as specified
Due 13 May 2008
Resolved 12 May 2008
Resolution: Verified that the vessel had relocated the high level alarm.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 11 May 2007 Resolved
Overnight accommodation space for passengers was not fitted with an independent smoke detector IAW 181.450.
Action required: 705 - Other - as specified
Due 11 May 2007
Resolved 11 May 2007
Resolution: Master purchased and installed during inspection.
Accommodation/Occupational Safety › Heating › Piping
Issued 24 April 2006 Resolved
Stove pipe for the wood stove is not approved material. Wood stove shall not be used until the approved stove pipe is installed.
Action required: 705 - Other - as specified
Resolved 25 May 2006
Resolution: Installed approved stove pipe.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 8 July 2005 Resolved
Restricted operations until repairs to exhaust system are made.
Action required: 705 - Other - as specified
Due 15 July 2005
Resolved 12 July 2005
Resolution: Builder redesigned exhaust manifold and shaft to alleviate incoming water.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 1 February 2005 Resolved
Provide a 3' lanyard and clip to L/B & light.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 May 2005
Resolved 2 May 2005
Resolution: Lanyard and clip provided.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 1 February 2005 Resolved
Affix retro-reflective material to the L/B's.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 May 2005
Resolution: Retro-reflective material added to the liferings.
Fire Fighting › Fire Bucket › Quantity
Issued 1 February 2005 Resolved
Required 3 fire buckets.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 May 2005
Resolved 2 May 2005
Resolution: Four fire buckets on board.

Casualty record · 8

8 July 2005Routine · role: Involved in a Marine Casualty · activity 2420079
30 May 2009Routine · role: Involved in a Marine Casualty · activity 3499672
27 September 2009Routine · role: Involved in a Marine Casualty · activity 3615875
24 June 2013Routine · role: Involved in a Marine Casualty · activity 4719496
7 September 2013Routine · role: Involved in a Marine Casualty · activity 4710379
10 September 2013Routine · role: Involved in a Marine Casualty · activity 4712098
3 September 2016Routine · role: Involved in a Marine Casualty · activity 5993399
7 June 2017Routine · role: Involved in a Marine Casualty · activity 6168759
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.