Records from 2014 to 2024. Most recent: inspection, 9 April 2024.
Inspection history · 15
9 April 2024
ORV Letter of Designation
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7892419
23 June 2022
ORV Letter of Designation
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7471233
12 April 2022
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7429588
19 May 2021
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7201284
19 April 2021
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7179281
29 December 2020
Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7117442
27 May 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6961865
16 April 2020
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6940520
9 March 2020
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6922910
22 February 2019
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6630414
11 February 2019
Hull Examination · Administrative Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6624039
13 December 2017
COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6323546
16 May 2017
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6143628
15 May 2017
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6147241
6 May 2016
Annual Inspection · DAPI Audit
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5870747
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 April 2021
Resolved
Ea. fire hose must be lined commercial fire hose that conforms to UL 19 or ... being equivalent in performance. The firehose is torn and leaks at the fitting to the fire hydrant. Replace with suitable fire hose.
CITE: Old-T 46CFR§181.15-10
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2021
Resolved 19 May 2021
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 April 2021
Resolved
Fire pump must be capable of providing adequate pressure. The pressure from the fire pump was insufficient to fight a fire. Prove proper operation of the vessel's fire pump w/discharge pressure sufficient to fight a fire.
CITE: Old-T 46CFR§181.10-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2021
Resolved 19 May 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 April 2021
Resolved
Ring buoys must be marked with Type II retro-reflective material approved in accordance with 46 CFR 164.018. The ring buoys did not have retro-reflective material. Apply retro-reflective material to the ring buoys.
CITE: 46 CFR §185.604(i)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2021
Resolved 19 May 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 April 2021
Resolved
For each marine casualty required to be reported ... the vessel shall determine whether there is any evidence of alcohol or drug use. The alcohol test swabs were out of date. Replace with unexpired swabs.
CITE: 46 CFR §4.06-15(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 May 2021
Resolved 19 May 2021
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 19 April 2021
Resolved
VHF radio w/DSC must be installed on dedicated, properly protected circuit. Both VHF radios are on the same circuit. Properly install VHF-DSC radio on dedicated circuit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2021
Resolved 19 May 2021
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 19 April 2021
Resolved
A First Aid Kit is to be provided onboard. Items in the 1st Aid Kit were out of date. Replace expired items.
CITE: 46 CFR §184.710
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2021
Resolved 19 May 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 April 2021
Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 × 30 mesh.
CITE: Old T 46 CFR §182.15-35(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2021
Resolved 19 May 2021
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 19 April 2021
Resolved
Dischg of pre-engineered Fireboy system must shut down power ventilation in ER. Power ventilation blowers are not connected and do not shut down when Fireboy is activated. Properly wire power ventilation to shutdown upon Fireboy activation. (Good marine practice: It was noted that the ER ventilation closures were not marked and that the crew was unfamiliar with how to close the vents. It is recommended to positively mark vents, familiarize crew in process for their closure, and incorporate the procedures into vsl's SMS manual.)
CITE: 46 CFR §181.420(a)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2021
Resolved 19 May 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 April 2021
Resolved
Blanks must be installed in electrical panels to prevent inadvertent contact with electric circuits. Blanks missing from panel behind helm seat. Properly install blanks.
CITE: Old-T 46 CFR §183.10-10
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2021
Resolved 19 May 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 January 2021
Resolved
Add chaffe gear to flexible fuel hoses in tank space compartment. 46 CFR 176.800
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 February 2021
Resolved 10 February 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 December 2020
Resolved
Battery chargers must be fitted with ammeter connected in the charging circuit. Dolphin Pro battery charger installed in the engine room was not observed having an ammeter. 46 CFR 183.350(f).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 January 2021
Resolved 26 January 2021
Resolution: Stand alone ammeter wired into battery charging circuit.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 December 2020
Resolved
Wire nuts on electrical splices need to be in an enclosure and the insulated cap of the connector must be secured to prevent loosening from vibration. Splices leading from the fire boy were not in an enclosure or secured. Place splices in enclosure or make permanent type connections. 46 CFR 183.340(g).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 January 2021
Resolved 26 January 2021
Resolution: Wire nuts removed and butt connectors installed. Could not test the system since vessel was out of water and engines couldn't be started. Vessel rep will test once back in the water and confirm system is proper.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 December 2020
Resolved
Owners/Operators must mitigate hazards from flammable liquids. Fuel piping on starboard side of fuel tank compartment was weeping fuel and wrapped in diapers to prevent leakage to the bilge. Repair piping and/or connections to stop leakage.46 CFR 176.830.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 January 2021
Resolved 26 January 2021
Resolution: Leaking fuel piping fittings replaced/repaired in tank space.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 March 2020
Resolved
A pre-engineered fixed gas fire extinguishing system must have a means to reset devices used to automatically shut down ventillation systems and engines at the operating station. The Captain was unable to restart the starboard engine after exercising the override.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 March 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 March 2020
Resolved
Individual power pumps used for separate spaces are to be controlled from a central control point and must have a light or other visual means at the control point to indicate operation. Fuse holder and fuse for fwd compartment bilge pump are missing at the control station rendering the bilge pump inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 March 2020
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 9 March 2020
Resolved
Each vessel that operates on the high seas must have on board a FCC type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate.
EPIRB was not installed in an automatic float free arrangement.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 March 2020
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 9 March 2020
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Paper charts are out of date and no longer valid. If electronic charts are utilized as primary source of navigation; documentation must be submitted to verify they are of the approved type.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 March 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 March 2020
Resolved
Each battery must be located as high above the bilge as practicable. One set of batteries are stored in the forward bilge of the engine room space.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 March 2020
Resolution: Per our conversation, attached images and due to the fact that the watertight integrity of the battery boxes has been verified by yourself and the fact that the bilge high level alarm activates prior to rising above the level of the battery boxes this def
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 March 2020
Resolved
Repairs or alterations to the fire detecting or fire extinguishing equipment must not be made without the approval of the cognizant [name withheld] extinguishing system was replaced with new clean agent pre-engineered system without cognizant OCMI acknowledgment. Provide evidence that the system is proper size and is installed in accordance with the manufacturer's instructions.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 March 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 March 2020
Resolved
Life jackets must be stored in convenient places and if kept in a stowage container must be readily available. Adult life jackets are kept in an enclosed space which can only be accessed by reaching behind an emergency escape ladder, which is not a convenient or readily available arrangement.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 March 2020
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 March 2020
Resolved
The Certificate of Inspection and Stability Letter must be framed under glass or other transparent material and posted in a conspicuous place. Neither document was posted at time of inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 March 2020
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 9 March 2020
Resolved
At least one ring life buoy must be fitted with a lifeline. If more than one ring life buoy is carried, at least one must not have a lifeline attached. Each lifeline must be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light. The vessel is certificated to carry one ring lifebuoy, however choses to have two. Remove the lifeline from one of the two and install an appropriate UV resistant lifeline.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 March 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 March 2020
Resolved
Electrical equipment on a vessel must be installed and maintained to minimize personnel contact with energized parts. The panel located behind the operating station had openings and a broken breaker. Place blanks on openings and replace broken breaker.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 March 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 March 2020
Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. There were cables spliced throughout the vessel, particularly in the engine space that were not within an enclosure. For cables that were spliced, ensure that the new cable is a stranded copper conductor with sufficient current carrying capacity for the circuit in which they are used. Prove that the cable spliced into the bucket control is appropriately rated and of marine grade. In addition, all cable and wire must be installed to avoid chafing and other damage. There were multiple cables throughout engine space that are significantly chafed. Replace damaged cable and ensure no cable or wire is running through the bilge.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 March 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 March 2020
Resolved
Ground detection for each alternating-current system that has a grounded neutral must have an ammeter that indicates the current in the ground connection. There is currently no ground detection for the system. Install appropriate ammeter.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 March 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 March 2020
Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 2 inches high: "Emergency Exit, Keep Clear". The escape hatch in the engine room was not properly marked.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 March 2020
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 5 March 2019
Resolved
Ensure at least one VHF radio has Digital selective Calling (DSC) capabilities with the vessel's MMSI number and GPS position programed in accordance with 47 CFR 80.1085(a)(2). The vessel will be restricted to carrying passengers if this requirement is not corrected no later than March 19, 2019.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2019
Resolved 8 March 2019
Resolution: The VHF radio on board was programed with the MMSI number for the vessel and interfaced with the GPS.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 5 March 2019
Resolved
Provide a current and valid Communications Act Safety Radio-telephony Certificate in accordance with 47 CFR 80.401. The vessel will be restricted to carrying passengers if this requirement is not corrected no later than March 19, 2019.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2019
Resolved 8 March 2019
Resolution: A new Safety Radiotelephony Certificate was issued to the vessel on March 8th. Certificate information was added to the MISLE Certificate Tab.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Bulwarks and freeing ports
Issued 11 February 2019
Resolved
Replace plastic through-hull fitting with metallic in aux space prior to completion of drydock.
Action required: 705 - Other - as specified
Resolved 22 February 2019
Resolution: Replaced with metallic fitting.
Construction/Loadline › Hull › Bottom Plating
Issued 13 December 2017
Resolved
Determine vessel's scantlings for below the waterline.
Due 20 December 2017
Resolved 19 December 2017
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 15 May 2017
Resolved
Properly wire and connect the starboard engine to the fixed fire extinguishing system.
Action required: 705 - Other - as specified
Due 29 May 2017
Resolved 30 May 2017
Resolution: A marine inspector attended the vessel to verify proper installation and wiring of the stbd engine to the fixed fire extinguishing system.