← All vessels
SEA HORIZON
SEA HORIZON is a 2003 tank ship. The Coast Guard has recorded 44 inspections since 2004, most recently in March 2022, along with 30 deficiencies and 11 operational controls.
Records from 2004 to 2022. Most recent: inspection, 21 March 2022.
- Built
- 2003
- Last inspected
- 21 March 2022
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 30 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9258026 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7A4999
669444
Flag
MALTA
—
Maury page id
psix-669444
Inspections, by type
…with no type recorded14
Years with a record
16 calendar years (2004–2022)
The 44 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it28529 - Convention (Subpart B), Gross Ton
12315 - Convention (Subpart B), Net Ton
47149 - Dead Weight, Ton
56524 - Displacement, Ton
12315 - Convention (Subpart B), Net Ton
47149 - Dead Weight, Ton
56524 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 44
21 March 2022
COC-TVE Annual · PSC B · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7414375
23 January 2021
COC-TVE Renew · Ballast Water Examination · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7129364
22 January 2021
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7130163
19 January 2021
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7126861
10 September 2020
PSC B · MARPOL Annex VI Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7055210
28 February 2020
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6916893
31 January 2020
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6900720
30 January 2020
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6902235
17 December 2019
COC-TVE Annual · Ballast Water Examination · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6873393
6 July 2019
Random ISPS/MTSA/PSC
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6734736
2 July 2019
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6733460
15 February 2019
MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6623888
11 December 2018
COE-Dockside · COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6591346
19 May 2017
Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6150267
23 December 2016
COE-Administrative
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6061674
14 November 2016
Ballast Water Examination · ISPS II Exam · PII Safety Exam · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6040390
5 October 2016
COC-TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6016426
5 October 2016
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6017053
16 August 2016
COE-Dockside
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5974227
17 September 2015
COC-TVE Renew · ISPS II Exam · Ballast Water Examination · COE-Offshore
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5721261
21 May 2012
NPV Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4317618
10 August 2011
Ballast Water Examination · ISPS II Exam · COC-TVE Renew · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4111095
14 January 2011
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3926500
7 December 2010
COC-TVE Annual · PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3905988
13 February 2008
MARPOL Annex V Examination · MARPOL Annex I Examination · ISPS III Exam · COC-TVE Annual · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3145067
14 January 2008
Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3130157
12 January 2008
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3129196
7 January 2008
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3125809
28 May 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2944068
30 March 2007
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2897136
12 March 2007
COC-TVE Annual · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2886381
22 August 2006
ISPS III Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2755655
22 February 2006
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2590259
6 February 2006
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2580161
5 February 2006
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2576848
5 February 2006
MARPOL Annex V Examination · MARPOL Annex I Examination · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2579417
5 February 2006
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2579538
22 September 2005
ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2498452
4 May 2005
COC-TVE Annual · MARPOL Annex V Examination · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2348868
23 April 2005
Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2345510
20 April 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2339094
15 July 2004
PII Safety Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2133809
9 July 2004
ISPS II Exam
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2127684
24 February 2004
Certificate of Compliance
Administrative · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 2012540
Deficiency record · 30
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 17 December 2019
Resolved
07102 - Fire Saftey - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will fit to proceed to sea without danger to the ship or persons on board. PSCO observed leakage in the scrubber sea water supply hose fitting.
SOLAS 74(2004) I/11-(a) 10c
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 17 December 2019
Resolved
07102 - Fire Safety - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will fit to proceed to sea without danger to the ship or persons on board. PSCO observed oxygen sampling line installed using velcro and metal bending strap.
SOLAS 74(2004) I/11-(a) 50ac
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 17 December 2019
Resolved
09211 - Working Conditions - The boilers associated piping systems and fittings shall be of a design for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to hot surfaces. PSCO observed leaking steam valve adjacent to #2 cargo pump turbine.
SOLAS 74(2001) II-1/26.1 10c
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 July 2019
Resolved
02199 - Structural - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Prior to arrival into the port of New Haven, CT, the crew observed a two inch crack on the pipeline (W 640-50-22G) that conntacts from the seachest to the marine growth protection system.
Solas 74 (2014 Cons.) I/11(a)
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 6 July 2019
Resolved
14104 - Pollution Prevention - The PSCO belives that there are clear grounds for believing that the master or crew are not familiar with essential shipboard procedures relating to the prevention of pollution by oil MPEC 107(49) states "Ship staff training should include familiarization in the operation and maintenance of the equipment." A new oil content meter was installed 17MAY2019. The engineering department was unaware how to retrieve information from the oil content meter.
MARPOL 73/78 (2017 Cons.) I/14.6
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 6 July 2019
Resolved
01117 - Certificates & Documentation - After any survey of the ship, no change shall be made in the structure, equipment systems, fittings, arrangements or material covered by the survey.
PSCO observed that the IOPP certificate reflected that the oil content meter is apporved in accordance with MPEC 60(33) however vessel is fitted with an oil content meter that is apporved in accordance with MPEC 107(49). Provide clarification from classification society reflecting correct information.
MARPOL 73/78 (2017 Cons.) I/6.4.2
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 6 July 2019
Resolved
01117 - Certificates & Documentation - The International Oil Pollution Prevention certificate shall be drawn up in the form corresponding to the model given in appendix II. IOPP Form B supplement indiciates capacity of incinerator is 580 kW, however manufacturer plate indicates maximum capacity of incinerator is 417 kW.
MARPOL 73/78 (2017 Cons.) I/9
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 15 February 2019
Resolved
The vessel shall prevent the ignition of combustible materials or flammable liquids and shall provide means to control leaks of flammable liquids. PSCO observed mulitple fuel oil leaks on the #1 and #2 generators on multiple cyclinders and a fuel oil leak on the #4 cyliner of the main diesel engine.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 February 2019
Resolved
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces, and other hazards. PSCO observed a substantial leak of feedwater and stear from the auxillary boiler recirculating pumps #1 and #2, multiple steam leaks from fuel trace lines, and a rubber hose being run from steam pressure relief valve to the cascade tank.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 February 2019
Resolved
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces, and other hazards. PSCO observed sumbstanital leak on the jacket water system for the generators at teh three way vavle just before the heat exchanger.
14 - Pollution Prevention › 141 - MARPOL Annex I › Retention of oil on board
Issued 15 February 2019
Resolved
Oil Residues (sludge) tanks shall be provided and shll be of adequate capacity having regard to the type of machiner and length of voyage, to receive the oil residues (sludge) which requirements of the Annex. Class Clarification on sludge capacity of vessel for next intended voyage. Vessel has sludge in seperating bilge oil tank and lube oil settling tank.
01 - Certificates & Documentation › 012 - Crew Certificates › Endorsement by flagstate
Issued 11 December 2018
Resolved
A seafarer is allowed to serve for a period not exceeding three months on board a ship entitled to fly it's flag. PSCO observed the chief engineers application to Malta flag for flag endorsemment is greater than three months old. STCW 1/10.5 17ac
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 11 December 2018
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service they are intended. PSCO observed the forward general service fire pump leaking excessively. 74 SOLAS (01) II-1/26 17ac
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 11 December 2018
Resolved
Every lifeboat shall consist of water receptacles containing a total of 3 liters of fresh water for each person the lifeboat is permitted to accommodate. PSCO observed lifeboats were not equipped with adequate water rations for the entire complement of the lifeboat. 74 SOLAS (14) III/34 LSA CODE 4.4.8.9
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 11 December 2018
Resolved
Every lifeboat shall consist of a food ration of not less than 10,000 KJ for each person the lifeboat is permitted to accommodate. PSCO observed lifeboats were not equipped with food rations for the entire complement of the lifeboat. 74 SOLAS (14) III/34 LSA CODE 4.4.8. 17ac
Deck/Cargo › Ballast › Piping
Issued 8 October 2016
Resolved
PSCO was informed by pumpman and 3rd Officer that a ballast line in the cargo pump room had a leak and was subsequently repaired. The crew was unable to provide any documentation demonstrating that the crew made the proper notifications per their SMS to their company, class, and flag to inform them of the temporary repairs, or that the temporary repairs were approved by class. See Form B for more.
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 6 October 2016
Resolved
When entering the pump room, PSCO observed the alarm had activated despite the space being recently certified safe for workers by a Marine Chemist. The PSCO questioned the vessel's Pumpman and 3rd Officer about the alarm, who explained that a ballast line had gasket had leaked in the space, flooding the lower gas detection sensors.
Deck/Cargo › Holds/Tanks › Portable Gas Measuring Equipment
Issued 5 October 2016
Resolved
Tankers shall be equipped with at least one portable instrument for measuring oxygen and one for measuring flammable vapors concentrations. Together with a sufficient set of spares, suitable means shall be provided for the calibration of such instruments. Portable gas detection meters are not able to be calibrated due to incorrect span gas on board.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 5 October 2016
Resolved
During an expanded exam of the SMS, with a focus on reporting requirements, PSCO observed crew was not following confined space entry procedures, and not reporting fixed and portable gas detection deficiencies since at least 015JUN2016. Additionally, PSCO identified falsified cargo operations checklists requiring the crew to calibrate portable gas and oxygen meters. The checklists show the task be
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 21 May 2012
Resolved
2540- Safety Management System -The vessel failed to respond to an onboard fire as required in their Safety Management Manual- SOLAS CHAP. IX REG 3.1
Operations/Management › Vessel Safety Management › Resources and Personnel
Issued 21 May 2012
Resolved
2510- SAFETY MANAGEMENT- Vessel could only provide records for 12 of the 21 crew onboard have received the required familiariazation training, specified by their safety management system. SOLAS CHAP IX REG 3.1. SOLAS CHAP III REG 2.1
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 21 May 2012
Resolved
2555- SAFETY MANAGEMENT -Vessel is not submitting forms RB-011 or CMS-011. These forms are required by their safety management system. SOLAS CHAP IX REG 3
Operations/Management › Vessel Safety Management › Safety/Environmental Protection Policy
Issued 21 May 2012
Resolved
2565- SAFETY MANAGEMENT -Based on Deficiencies 2,3 and 4, the PSCO has objective evidence that a major non-comformity exists with regards to the implementation of the safety management system on board. An external audit is requested. SOLAS CHAP I REG 19, SOLAS CHAP IX REG 6
Engineering › Diesel Engine (auxiliary) › Turbocharger
Issued 21 May 2012
Resolved
1430- MAINENTANCE OF EQUIPMENT -#1 Generator turbo charger malfunctioned causing burning embers and carbon soot to be emitted out of the exhaust stack. SOLAS CHAP I REG 11
Engineering › Steering Gear System › Pump
Issued 7 December 2010
Resolved
Observed hunting in steering system only when #1 steering pump was in operation and given portside commands.
Construction/Loadline › Hull › Hull Plating
Issued 7 December 2010
Resolved
vessel hull in way of the wind waterline is covered with barnaces that present a hazard to the marine environment.
Navigation › Collision/Grounding Avoidance › Radar
Issued 14 January 2008
Resolved
Vessel has inoperable radar.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom
Issued 12 March 2007
Resolved
Make cargo pumproom available for inspection at next U. S. port. Vessel had obtained marine chemist's certificate but failed to maintain conditions of certificate, thereby invalidating it.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom
Issued 4 May 2005
Resolved
Certified Marine Chemist was unavailable to certify pumproom "Safe for Workers" prior to COC-T Annual to allow USCG Inspectors to inspect cargo pumproom. Prior to conducting cargo operations, have Certified Marine Chemist certify pumproom "Safe for Workers" and fax a copy of report to COTP NY.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom
Issued 24 February 2004
Resolved
PUMPROOM NOT INSPECTED BECAUSE THERE IS NO MARINE CHEMIST IN THE TERRITORY TO CERTIFY THE CARGO PUMPROOM SAFE FOR ENTRY.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.