Documentation record
Registered dimensions (L × B × D)41.5 ft × 10.5 ft × 5.7 ft
Registered tonnagegross 16 / net 13
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSTRAUDACHER YACHTS, INC.
Hull materialOther
PropulsionGasoline Inboard
Hull shapeShip
Hull configurationMonohull
Hailing portCLAYTON, NY
Endorsements, as the file codes themcw_un, rec
DocumentationValid · issued 11 May 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it16 - Simplified, Gross Ton
13 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 18 inspections, each with its date, unit and type; 9 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 18
27 May 2026
COI Inspection · Vessel Attendance
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 8371729
29 May 2025
Annual Inspection
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 8153144
25 June 2024
Annual Inspection
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 7939384
19 July 2023
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7709251
25 April 2023
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7670954
22 June 2022
Annual Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7484237
1 July 2021
COI Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7213458
3 July 2020
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6987842
24 June 2019
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6719467
27 June 2018
Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6457418
18 June 2018
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6448509
18 June 2018
Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6456878
4 May 2018
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6406027
17 July 2017
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6211526
19 October 2016
Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6025364
23 June 2016
COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 5916494
12 June 2016
Damage Survey · Deficiency Check
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 5916417
3 May 2016
Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 5868447
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 19 July 2023
Resolved
(a) On a vessel of at least 7.9 meters (26 feet) in length,
a visual and audible alarm must be provided at the
operating station to indicate a high water level in each
of the following normally unmanned spaces:
(1) A space with a through-hull fitting below the deepest
load waterline, such as a lazarette;
(2) A machinery space bilge, bilge well, shaft alley
bilge, or other spaces subject to flooding from sea water
piping within the space
Vessel engine room bilge alarm not providing notification to the operating station for high water alarm. Repair or replace
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 July 2023
Resolution: Vessel rep discovered a blown fuse, replaced, tested satisfactorily.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 July 2023
Resolved
(a) At each initial and subsequent inspection for
certification, the owner or managing operator must be
prepared to conduct tests and have the vessel ready for
inspection of its fire protection equipment, including the
following:
(1) Inspection of each portable fire extinguisher, semiportable fire extinguisher, and fixed gas fire
extinguishing system to check for excessive corrosion and general condition
Vessel portable fire extinguishers have not been serviced since 2021. Provide proof of servicing once complete.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 July 2023
Resolution: Annual inspection of all fire extinguishing equipment has been completed by [name withheld] Equipment Inc. and vessel rep provided documentation of inspection. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 July 2023
Resolved
(b) Each battery must be located as high above the bilge
as practicable, secured to protect against shifting with
the roll and pitch of the vessel, and free from exposure
to water splash or spray.
Port propulsion engine starting battery is not secured.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 July 2023
Resolution: Port battery has been secured. All sat
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 July 2023
Resolved
The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket.
Fire buckets missing labeling "FIRE BUCKET" on each. Properly stencil each bucket and stow to be readily accessible.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2023
Resolved 19 July 2023
Resolution: Fire buckets have been properly labeled and stowed appropriately. All sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 June 2019
Resolved
Port main engine exhaust muffler was found to be wasted at the bottom with a small hole allowing water and exhaust fumes into the bilge space under the passenger space.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 June 2019
Resolution: Local fab shop cut away wasted aluminum and welded patch over wasted area. Patch was lapped over by 1" and welded. Tested satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 June 2019
Resolved
Found one of the exhaust hoses for the ventilation in the fuel tank compartment vertically installed sucking bilge water. Operator to remove water and install 90 degree elbow and lay hose on floor of the bilge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 July 2019
Resolved 26 June 2019
Resolution: Vsl rep installed 90 degree elbow allowing vapors to still be removed from the bilge area.
Engineering › Gasoline Engine (propulsion) › Alternator (4 cycle)
Issued 17 July 2017
Resolved
Current installed alternators appear to be of the automotive style with open venting. Vessel rep to provide proof that installed alternators are of the "ignition protected" type.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 July 2017
Resolution: After MI calling manufacturer using serial and family type numbers, it was confirmed that the alternators installed are that of the "ignition protected" type.
Construction/Loadline › Hull › Transverse Frame
Issued 23 June 2016
Resolved
Inspect frames #5 & 6 counting from the stern of the vessel. Both frames have cracks in them just above the keel. Submit a repair proposal to a marine inspector for review.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 1 August 2016
Resolved 22 November 2016
Resolution: Frames 5 and 6 were removed. New frames installed.
Engineering › Gasoline Engine (propulsion) › Carburetor (4 cycle)
Issued 12 June 2016
Resolved
Starboard engine would not start. Vessel restricted from carrying passengers until repairs made.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 July 2016
Resolved 1 July 2016
Resolution: The carburetor was removed, cleaned and reinstalled. Engine rus smooth.