FULL MOON is a 1950 passenger vessel (inspected). The Coast Guard has recorded 56 inspections since 1987, most recently in March 2026, along with 106 deficiencies.

Records from 1987 to 2026. Most recent: inspection, 23 March 2026.

Built
1950
Last inspected
23 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDK4632
Flag
UNITED STATES
368057170
Maury page id
psix-66979

Inspections, by type

…with no type recorded4
Years with a record 31 calendar years (1987–2026)
The 56 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)63.0 ft × 15.8 ft × 7.4 ft
Registered tonnagegross 56 / net 50
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHENRY C. GREBE, BUILDER · CHICAGO, IL, UNITED STATES · built 1950
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBOSTON, MA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 13 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it56 - Regulatory (Subpart C or D), Gross Ton
50 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDK4632MMSI 368057170 · active · compulsorily equipped · granted 1 September 2018, expires 1 September 2028
WDH6072MMSI 367634370 · expired · compulsorily equipped · granted 29 July 2014, cancelled 28 September 2024
WDC6383MMSI 367055580 · expired · compulsorily equipped · granted 12 July 2005, cancelled 19 September 2015
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 56

23 March 2026 Internal Structural Exam · Vessel Attendance · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8329985
25 November 2025 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8273408
1 October 2025 Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8244379
12 February 2025 Plan Review "T" Boat
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8079301
19 December 2024 Deficiency Check · Examination of Repairs · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8062657
10 October 2024 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8017147
27 June 2024 Plan Review "T" Boat · Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7924180
5 March 2024 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7875460
14 September 2023 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7757360
22 September 2022 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7564044
30 March 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7601025
28 October 2021 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7341387
4 June 2021 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7215626
2 November 2020 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7088260
10 March 2020 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6925635
8 October 2019 Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6831648
4 July 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6741388
8 February 2018 Simplified Stability Test · Drydock Exam · In-Service Inspection · Internal Structural Exam · Plan Review "T" Boat · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6542276
22 April 2016 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5859406
6 October 2015 Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5736869
3 September 2015 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5233985
18 June 2012 COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4344907
1 June 2012 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4333285
8 February 2012 Drydock Extension
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4243530
16 December 2011 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4213086
6 December 2011 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4203063
14 July 2011 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4080828
15 December 2009 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3651875
9 December 2008 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3376667
16 October 2007 Re-Inspection · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3081062
21 November 2005 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2538197
8 July 2005 COI Inspection · Simplified Stability Test
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2583277
28 September 2004 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2232179
21 September 2004 Plan Review "T" Boat
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2200837
4 September 2001 Plan Review "T" Boat
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2272178
9 April 2001 Plan Review "T" Boat
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1471761
4 October 1999 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1388918
9 June 1997 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 774463
6 March 1997 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 119909
6 March 1997 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 135612
15 January 1997 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1094195
6 June 1996 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1377736
6 July 1995 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1355330
27 May 1994 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1330894
27 May 1994 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1330896
1 June 1993 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 860423
8 June 1992 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1425268
20 March 1992 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 956939
28 June 1991 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1251565
3 June 1991 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1200810
3 June 1991 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1227093
1 June 1990 COI Inspection · Drydock Extension
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 907954
26 October 1989 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 894978
15 June 1989 Re-Inspection · Drydock Extension
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1209069
16 June 1988 Deficiency Check · Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1345071
3 June 1987 Initial Certification · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1017221

Deficiency record · 106

02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 27 June 2024 Resolved
During 'New to Zone' inspection: Inside engineroom, on port side hull, the 2nd transverse wood frame aft of the forward engineroom watertight bulkhead (located directly behind the E/R door entrance): this frame was found cracked in 2 places, in way of the 2 fasteners just above the gusset. See MISLE activity for picture/location of cracked frame. Before repairs are conducted, the owner shall contact the local USCG OCMI and submit a repair plan proposal for acceptance. Until this deficiency is cleared, the vessel is restricted to a river's route not more than 1000' from shore, or must be completed before 01 DEC 2024: whichever comes first. 46 CFR 176.25-5(a)(1) (OLD SUBCHAPTER T) CODE 705C
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2024
Resolved 31 January 2025
Resolution: resolved by 8062657
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 27 June 2024 Resolved
During 'New to Zone' inspection: Inside engineroom, 2' section of keelson found decaying and wet rotted through 80%. Location: where the aluminum vertical deck support column interfaces with the keelson in the aft 3/4 of the engineroom between the two main engines. See MISLE activity for picture/location of the rot. Before repairs are conducted, the owner shall contact the local USCG OCMI and submit a repair plan proposal for acceptance. Until this deficiency is cleared, the vessel is restricted to a river's route not more than 1000' from shore, or must be completed before 01 DEC 2024: whichever comes first. 46 CFR 176.25-5(a)(1) (OLD SUBCHAPTER T)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 December 2024
Resolved 31 January 2025
Resolution: Rot was cleaned out and treated with borax. Special note added to continue monitoring. Vessel placed on annual dry dock schedule.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 27 June 2024 Resolved
Found diesel fuel leak from the discharge fitting from the secondary fuel oil filer serving the generator. 46 CFR 176.25-10(a)(4) (old T)
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 27 June 2024
Resolved 3 July 2024
Resolution: Fitting tightened, observed no leaks.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 27 June 2024 Resolved
Found diesel fuel leak from ball valve fitting just before entering the fuel/water separator serving the generator. 46 CFR 176.25-10(a)(4) (old t)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 June 2024
Resolved 3 July 2024
Resolution: Fitting tightened, does not leak.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 27 June 2024 Resolved
Found diesel fuel leak from the overflow crossover ball valve in the aft overhead space of the engineroom. 46 CFR 176.25-10(a)(1) (old t)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 June 2024
Resolved 3 July 2024
Resolution: Fitting tightened, does not leak.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 June 2024 Resolved
Found battery acid leaking from forward 24V battery located centerline in the engineroom. 46 CFR 176.25-10(a)(4)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 June 2024
Resolved 3 July 2024
Resolution: Battery cleaned, re-charged and did not leak.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 March 2024 Resolved
Nothing in the part shall be construed as limiting the marine inspector from making such tests or inspections as reasonable and practicable to be assured of the seaworthiness of the vessel. Prior to carrying passengers, make vessel available to Coast Guard Marine Inspector for sea trial.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 April 2024
Resolution: Vessel completed satisfactory sea trial for CG's review/approval.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 March 2024 Resolved
Provisions must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. Identified open bulkhead penetrations in the forward and aft engine room bulk heads, shaft penetrations, starboard aft corner ladder connecting to the operators console and in way of vessel side shell and deck cable penetrations.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 April 2024
Resolution: Vessel made alterations to engine space to ensure its vapor tight integrity. MI conducted a satisfactory light test in the compartment.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 March 2024 Resolved
Irrespective of build date, a vessel to which this subchapter applies must meet 46 CFR 181.405, 181.450, 181.500, 185.364, and 185.420(b), if it is not a ferry, and if it, (1) Has overnight accommodations for passengers. Vessel is identified as a Cover Small Passenger vessel due having sleeping accommodations below deck. Propose plan forward IAW CG-CVC PL 23-03.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2024
Resolution: added the following verbiage to COI PASSENGERS ARE PROHIBITED ACCESS TO OVERNIGHT ACCOMMODATION SPACES. Attending MI witnessed proper signage for each "crew only" spaces.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 September 2022 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Grab lines on ring life buoy wasted & worn. Lettering for the vessel's name was peeling and requires renewal. Owner operator shall provide photo of the renewed ring life buoy.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 October 2022
Resolved 28 September 2022
Resolution: Provided documentation attesting to the renewal of the vessels ring life buoy.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 22 September 2022 Resolved
Fuel shutoff valves shall be installed so as to close against the fuel flow, fitted in the fuel supply lines one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. During the inspection port and starboard fuel tank remote shut off vale(s) were seized/inoperable and unable to be secured from the remote pull station. Vessel owner/operator shall provide an alternative procedure to keep main fuel tanks secured while u/w carrying passengers and just run on the day tank until permanent repairs are made. Submit the above plan upon receipt of this report. Within 14 days provide photographic documentation for our records attesting to adequate repairs rendering both remote operated fuel shut off vales fully operational & free of binding.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 October 2022
Resolved 28 September 2022
Resolution: Recieved documentation attesting to the proper operation of the vessels remote fuel shut off valve arrangement.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 8 October 2019 Resolved
Found that emergency exits were not marked IAW 46 CFR 185.606 “All means used as emergency escapes shall be marked EMERGENCY EXIT, KEEP CLEAR in 50mm letters.”
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 October 2019
Resolved 22 October 2019
Resolution: Recieved picture proof of corrected deficiency
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 October 2019 Resolved
The retro-reflective tape on numerous life jackets were found to be disintegrated. Deficiency issues to check entire inventory of life-jackets and replace IAW 46 CFR 185.604(h) type one retro-reflective tape.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 October 2019
Resolved 22 October 2019
Resolution: Recieved picture proof of corrected deficiency
Construction/Loadline › Hull › Keel
Issued 2 November 2015 Resolved
Complete a credit hull exam prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 September 2018
Resolution: credit dry dock has been complete.
Electrical › Electrical Distribution System (service) › Cable
Issued 9 October 2015 Resolved
Found numerous extension cords and surge protectors feeding permanently installed equipment, issued requirement to remove extension cords and surge protectors. 46 CFR 183.10-20
Action required: 705 - Other - as specified
Due 23 October 2015
Resolved 26 September 2018
Resolution: Complete
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder
Issued 6 October 2015 Resolved
Engine failed to start. Vessel rep said that the head gasket was wasted. Issued a CG-835 to repair and operationally test the engine prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 September 2018
Resolution: Vessel was repowered
Construction/Loadline › Hull › Keel
Issued 3 September 2015 Resolved
Keel was found to be rotted and keel 2-3 keel bolts were not holding; require 3rd party survey. Require credit hull exam prior to departure for FL / departure from Boston. Limit route to protected Lakes, Bays, and Sounds,
Action required: 705 - Other - as specified
Resolved 29 September 2015
Resolution: No longer require third party survey as we referred to the one previously done in April 2014. Vessel is authorized to operate for the rest of the season (until November 1, 2015). Vessel will no longer be traveling to FL in the off season.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 3 September 2015 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 3 October 2015
Resolved 26 September 2018
Resolution: Complete
Documentation › Logs/Records › Drug Test Records
Issued 3 September 2015 Resolved
Provide Drug and Alcohol Documentation prior to carrying passengers.
Action required: 705 - Other - as specified
Resolved 23 September 2015
Resolution: Received documents proving crew is involved in a drug and alcohol program. Reiterated to vessel rep that no one can operate the vessel without proof that they are enrolled in a drug and alcohol program.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 3 September 2015 Resolved
Renew ring buoy grab line, water light, and retro reflective material prior to operating at night.
Action required: 705 - Other - as specified
Resolved 23 September 2015
Resolution: Verified the ring buoy grab line, water light, and retro reflective material were renewed and operationally tested SAT.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 3 September 2015 Resolved
Log firefighting and MOB drills.
Action required: 705 - Other - as specified
Due 17 September 2015
Resolved 23 September 2015
Resolution: Verified MOB and firefighting drills were logged.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 3 September 2015 Resolved
Develop procedure to track passenger count.
Action required: 705 - Other - as specified
Due 17 September 2015
Resolved 23 September 2015
Resolution: Verified there was a procedure in place to track passenger count.
Navigation › Piloting/Steering › Marine Charts
Issued 3 September 2015 Resolved
Provide charts of the operating area.
Action required: 705 - Other - as specified
Due 17 September 2015
Resolved 23 September 2015
Resolution: Verified there were charts on board of the operating area.
Fire Fighting › Fire Bucket › Capacity
Issued 3 September 2015 Resolved
Provide three 2.5 gallon fire buckets with lanyard.
Action required: 705 - Other - as specified
Due 17 September 2015
Resolved 23 September 2015
Resolution: Verified there were three 2.5 gallon buckets on board.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 3 September 2015 Resolved
Provide approved bracket for fire extinguisher in forward compartment.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 September 2015
Resolved 5 October 2015
Resolution: Verified the fire extinguisher in the forward compartment was installed with an approved fire extinguisher.
Electrical › Electrical Distribution System (service) › Shore Connection Box
Issued 3 September 2015 Resolved
Provide plans to make electrical shore power and switchboard in compliance with required interlock and approved enclosures; install in accordance with approved plans.
Action required: 705 - Other - as specified
Due 3 October 2015
Resolved 26 September 2018
Resolution: Complete
Electrical › Electrical Distribution System (service) › Junction Box
Issued 3 September 2015 Resolved
Rewire stove circuit with marine cable or UL boat cable and terminate improper junction box.
Action required: 705 - Other - as specified
Due 3 October 2015
Resolved 26 September 2018
Resolution: Complete
Electrical › Lighting (service) › Lighting Branch Circuit
Issued 3 September 2015 Resolved
Renew galley receptical circuit with approved UL boat marine cable.
Action required: 705 - Other - as specified
Due 3 October 2015
Resolved 26 September 2018
Resolution: Complete
Electrical › Electrical Distribution System (service) › Cable
Issued 3 September 2015 Resolved
Remove all dead ended cables not to be used for refit; label and tape off remaining dead ended cables.
Action required: 705 - Other - as specified
Due 3 October 2015
Resolved 26 September 2018
Resolution: Complete
Engineering › Bilge Water Management System › Pump
Issued 18 June 2012 Resolved
Galley bilge pump inoperable. Make repairs, test in presence of CGMI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 June 2012
Resolution: Made repairs, tested in presence of [name withheld]
Engineering › Bilge Water Management System › Interface Detector
Issued 18 June 2012 Resolved
Visual indicator for bilge high water level is inoperable. Make repairs, test in presence of CGMI.
Due 29 June 2012
Resolved 22 June 2012
Resolution: Made repairs, tested in presence of [name withheld]
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 18 June 2012 Resolved
All Lifebuoys missing retro-reflective tape and waterlight non corosive clip. Install retro tape and clip.
Due 12 July 2012
Resolved 6 July 2012
Resolution: Life buoy properly marked with SOLAS reflective tape, provided with shackle.
Documentation › Markings/Placards › Lifejacket Placard
Issued 18 June 2012 Resolved
Life jacket placard missing. Provide life jacket placard.
Due 12 July 2012
Resolved 6 July 2012
Resolution: Life jacket placard printed & installed.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 18 June 2012 Resolved
CG Light List missing. Provide CG Light List
Due 12 July 2012
Resolved 22 June 2012
Resolution: Provided CG Light List
Engineering › Fuel Oil Service System › Piping
Issued 14 July 2011 Resolved
STBD Eng fuel line has temp patch placed on line to prevent small fuel leak. Fix to the SAT of MI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 July 2011
Resolved 5 August 2011
Resolution: Starboard engine fuel line replaced with new. Inspected and examined for leaks, all sat.
Engineering › Bilge Water Management System › Not Operational
Issued 14 July 2011 Resolved
Steering bilge high level alarm at operating station does not alarm. Check space every hour.
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 July 2011
Resolved 26 August 2011
Resolution: Bilge alarm operating properly. Cancelled hourly watch requirement.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 14 July 2011 Resolved
STBD and Port rails fwd do not have screws on the supports to the deck. Replace to the SAT of MI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 July 2011
Resolved 18 August 2011
Resolution: Placed new screws into the deck and secured rails.
Engineering › Bilge Water Management System › Not Operational
Issued 14 July 2011 Resolved
Vessel is not to carry more than 6 passenger until high level alarm is fix in steering compartment.
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 September 2011
Resolved 26 August 2011
Resolution: Tested bilge alarm operation tested satisfactory at the operating station. Vessel may operate at maximum passenger count as per the COI.
Construction/Loadline › Hull › Bottom Plating
Issued 15 December 2009 Resolved
Vessel is pending an underway hull exam prior to receiving credit for dry dock. Vessel owner/operator must contact CG marine inspector to schedule and complete underway hull exam and obtain dry dock credit prior to carrying passengers.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 February 2010
Resolved 13 May 2010
Resolution: Conducted underway hull exam with satisfactory results. Granted credit for dry dock
Lifesaving › Hand Flares › Not on Board
Issued 16 October 2007 Resolved
Provide orange smoke signal flares.
Due 8 November 2007
Resolved 29 November 2007
Resolution: Provided sat.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 16 October 2007 Resolved
replace inop battery for waterlight on lifering.
Due 8 November 2007
Resolved 29 November 2007
Resolution: Provided sat.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 16 October 2007 Resolved
provide light list,current corrected charts for Boston, MA. and Miami, FL.
Due 8 November 2007
Resolved 29 November 2007
Resolution: Provided sat.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 16 October 2007 Resolved
provide 4" courses for deck rail.
Due 8 November 2007
Resolved 29 November 2007
Resolution: Provided sat.
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 16 October 2007 Resolved
Have all vessel fixed and portable fire extinquishers inspected.
Due 8 November 2007
Resolved 29 November 2007
Resolution: Provided sat.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 16 October 2007 Resolved
provide current COD.
Due 8 November 2007
Resolved 29 November 2007
Resolution: Provided sat.
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 16 October 2007 Resolved
Provide proof of enrollment in drug and alchol testing program.
Due 8 November 2007
Resolved 29 November 2007
Resolution: Provided sat.
Fire Fighting › Fire Bucket › Quantity
Issued 16 October 2007 Resolved
Provide two more fire buckets.
Due 8 November 2007
Resolved 29 November 2007
Resolution: Provided sat.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 16 October 2007 Resolved
Provided machinery guards for both port and starboard MDE'S.
Due 8 November 2007
Resolved 29 November 2007
Resolution: Provided sat.
Construction/Loadline › Hull › Bottom Plating
Issued 29 June 2005 Resolved
Repair leak in lazarette located IWO transom and bottom planking junction.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 July 2005
Resolved 8 July 2005
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 29 June 2005 Resolved
Post life preserver donning placard.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 July 2005
Resolved 8 July 2005
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 29 June 2005 Resolved
Obtain and show FCC station License.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 July 2005
Resolved 8 July 2005
Documentation › Markings/Placards › Lifejacket Placard
Issued 29 June 2005 Resolved
Post emergency broadcast placards.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 July 2005
Resolved 8 July 2005
Documentation › Markings/Placards › Warning Signs
Issued 29 June 2005 Resolved
Post emergency instruction placard.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 July 2005
Resolved 8 July 2005
Personnel › Certificates/Documents/Licenses › License, Operator
Issued 29 June 2005 Resolved
Provide Master's merchant mariner license and FCC operator permit.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 July 2005
Resolved 8 July 2005
Deck/Cargo › Mooring/Anchoring › Anchor Cable
Issued 29 June 2005 Resolved
Attach anchor line to the anchor.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 July 2005
Resolved 8 July 2005
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 29 June 2005 Resolved
Provide a total of 6 child life preservers.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 July 2005
Resolved 8 July 2005
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 29 June 2005 Resolved
Provide watertight on detachable clip and 60 ft UV-resistant 5/16 " line for ring buoy.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 July 2005
Resolved 8 July 2005
Lifesaving › Visual Distress Signals (General) › Not on Board
Issued 29 June 2005 Resolved
Provide one additional red and 1 additional orange distress signals.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 July 2005
Resolved 8 July 2005
Electrical › Electric Supply System (service) › Battery Installation
Issued 29 June 2005 Resolved
Enclose batteries in battery boxes.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 July 2005
Resolved 8 July 2005
Engineering › Fuel Oil Service System › Valve
Issued 29 June 2005 Resolved
Label emergency fuel shut-offs.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 July 2005
Resolved 8 July 2005
Engineering › Fuel Oil Service System › Hose
Issued 29 June 2005 Resolved
Install bonding straps on fuel oil fill hoses to the tanks.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 July 2005
Resolved 8 July 2005
Engineering › Fuel Oil Service System › Valve, Control
Issued 29 June 2005 Resolved
Install fuel oil shut off remote pulls.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 July 2005
Resolved 8 July 2005
Engineering › Fuel Oil Service System › Filter
Issued 29 June 2005 Resolved
Provide fire shield for port and starboard main engine Racor filters.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 July 2005
Resolved 8 July 2005
Documentation
Issued 6 June 1996 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 6 August 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 6 June 1996 Resolved
REPLACE YELLOW LINES ON BOUYANT APPARATUS THAT ATTACH THE WATERLIGHT.
Condition: Unknown
Due 14 June 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 6 June 1996 Resolved
OBTAIN DAILY MAINTAINENCE LOGBOOK.
Condition: Unknown
Due 14 June 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 8 June 1992 Resolved
Install stern light in accordance with inland navigational rules.
Condition: Unknown
Due 8 June 1992
Resolved 8 June 1992
Lifesaving
Issued 3 June 1991 Resolved
PROVIDE 18' LINE FOR RING BUOY AND TWO BUOYANT APPARATUS WATERLIGHTS
Condition: Unknown
Due 3 June 1991
Resolved 3 June 1991
Engineering
Issued 3 June 1991 Resolved
PROVIDE 30X30 MESH FLAME SCREENS FOR FUEL TANK VENTS
Condition: Unknown
Due 3 June 1991
Resolved 3 June 1991
Electrical
Issued 3 June 1991 Resolved
REMOVE WIRE NUTS FROM STEERING COMPARTMENT & MAST
Condition: Unknown
Due 3 June 1991
Resolved 3 June 1991
Engineering
Issued 3 June 1991 Resolved
REMOVE PLASTIC BILGE HOSE FROM STEERING COMPARTMENT
Condition: Unknown
Due 3 June 1991
Resolved 3 June 1991
Electrical
Issued 3 June 1991 Resolved
SECURE 12V BATTERY FOR GENERATOR
Condition: Unknown
Due 3 June 1991
Resolved 3 June 1991
Navigation
Issued 3 June 1991 Resolved
REPOSITION ALL ROUND WHITE ON MAST FOR PROPER VISIBILITY
Condition: Unknown
Due 3 June 1991
Resolved 3 June 1991
Electrical
Issued 3 June 1991 Resolved
PROVIDE AMMETER, VOLTMETER AND FREQUENCY METER FOR GENERATOR
Condition: Unknown
Due 3 June 1991
Resolved 3 June 1991
Navigation
Issued 3 June 1991 Resolved
PROVIDE COAST PILOT
Condition: Unknown
Due 3 June 1991
Resolved 3 June 1991
Documentation
Issued 3 June 1991 Resolved
POST COI & LICENSES IN CONSPICUOUS LOCATION
Condition: Unknown
Due 3 June 1991
Resolved 3 June 1991
Navigation
Issued 3 June 1991 Resolved
PROVE PROPER OPERATION OF RADAR
Condition: Unknown
Due 3 June 1991
Resolved 3 June 1991
Navigation
Issued 3 June 1991 Resolved
REPLACE BULB IN PORT AND STARBOARD SIDE LIGHTS
Condition: Unknown
Due 3 June 1991
Resolved 3 June 1991
Documentation
Issued 1 June 1990 Resolved
PROVIDE FCC OPERATORS PERMIT
Condition: Unknown
Due 1 June 1990
Resolved 1 June 1990
Documentation
Issued 1 June 1990 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 1 June 1990
Resolved 1 June 1990
Documentation
Issued 1 June 1990 Resolved
PROVIDE MSO A LETTER REQUESTING A DRYDOCK EXTENSION
Condition: Unknown
Due 1 June 1990
Resolved 1 June 1990
Navigation
Issued 15 June 1989 Resolved
PROVIDE FCC OPERATORS LICENSE
Condition: Unknown
Due 15 June 1989
Resolved 15 June 1989
Navigation
Issued 15 June 1989 Resolved
PROVIDE TIDE TABLES
Condition: Unknown
Due 15 June 1989
Resolved 15 June 1989
Lifesaving
Issued 15 June 1989 Resolved
RENEW LIFELINE TO STBD RING BUOY
Condition: Unknown
Due 15 June 1989
Resolved 15 June 1989
Lifesaving
Issued 15 June 1989 Resolved
LABEL PFD STOWAGE IN FWD AFT DECK
Condition: Unknown
Due 15 June 1989
Resolved 15 June 1989
Navigation
Issued 15 June 1989 Resolved
PROVIDE THREE ORANGE DISTRESS FLARES
Condition: Unknown
Due 15 June 1989
Resolved 15 June 1989
Unknown
Issued 16 June 1988 Resolved
PROVIDE LIGHT ON NAVIGATION PANEL FOR AUTOMATIC FIXED BILGE SYSTEM.
Condition: Unknown
Due 16 June 1988
Resolved 16 June 1988
Unknown
Issued 16 June 1988 Resolved
PROVIDE PROOF OF SERVICING OF FIXED CO2 SYSTEM.
Condition: Unknown
Due 16 June 1988
Resolved 16 June 1988
Unknown
Issued 16 June 1988 Resolved
PROVIDE NEW TERMINAL FOR 12 VOLT BATTERY LOCATED FWD ENGINE ROOM.
Condition: Unknown
Due 16 June 1988
Resolved 16 June 1988
Unknown
Issued 16 June 1988 Resolved
PROVIDE CURRENT COPY OF FCC OPERATORS LICENSE
Condition: Unknown
Due 16 June 1988
Resolved 16 June 1988
Unknown
Issued 3 June 1987 Resolved
EXTEND ONE VENT IN MACHINERY SPACE AS CLOSE AS POSSIBLE TO BILGE. MECHANI-CAL VENTILATION SHALL OPERATE SO AS TO EXHAUST BILGE.
Condition: Unknown
Due 3 June 1987
Resolved 3 June 1987
Unknown
Issued 3 June 1987 Resolved
TIGHTEN BLOCK SUPPORTING INTERMEDIATE SHAFT BEARING ON PORT AND STBD SHAFTS.
Condition: Unknown
Due 3 June 1987
Resolved 3 June 1987
Unknown
Issued 3 June 1987 Resolved
PROPERLY MARK CIRCUIT BREAKER PANEL BOARDS.
Condition: Unknown
Due 3 June 1987
Resolved 3 June 1987
Unknown
Issued 3 June 1987 Resolved
PROVIDE GLOBES TO LIGHTS IN MACHINERY SPACE (4).
Condition: Unknown
Due 3 June 1987
Resolved 3 June 1987
Unknown
Issued 3 June 1987 Resolved
PROVIDE FCC SAFETY CERTIFICATE (RADIO TELEPHONE) AND OPERATORS LICENSE.
Condition: Unknown
Due 3 June 1987
Resolved 3 June 1987
Unknown
Issued 3 June 1987 Resolved
INSTALL CG APPROVED MSD.
Condition: Unknown
Due 3 June 1987
Resolved 3 June 1987
Unknown
Issued 3 June 1987 Resolved
PROVIDE EMERGENCY CHECK-OFF LIST AND MOUNT ON BOARD VESSEL.
Condition: Unknown
Due 3 June 1987
Resolved 3 June 1987
Unknown
Issued 3 June 1987 Resolved
SUBMIT VESSEL PLANS AS REQUIRED BY 46CFR177.05-1.
Condition: Unknown
Due 3 June 1987
Resolved 3 June 1987
Unknown
Issued 3 June 1987 Resolved
PROVIDE ONE ADDITIONAL WATERLIGHT FOR ONE BUOYANT APPARATUS.
Condition: Unknown
Due 3 June 1987
Resolved 3 June 1987
Lifesaving
Issued 3 June 1987 Resolved
PROVIDE TWO ADULT PFD.
Condition: Unknown
Due 3 June 1987
Resolved 3 June 1987
Lifesaving
Issued 3 June 1987 Resolved
PROVIDE MEANS OF SECURING PORT VENT TO MACHINERY SPACE.
Condition: Unknown
Due 3 June 1987
Resolved 3 June 1987
Unknown
Issued 3 June 1987 Resolved
PROVIDE COMPLETE BUT SIMPLE INSTRUCTIONS ON METHOD OF DISCHARGING CO2 SYSTEM.
Condition: Unknown
Due 3 June 1987
Resolved 3 June 1987
Unknown
Issued 3 June 1987 Resolved
REPLACE ALL FLEXIBLE FUEL HOSE WHIC IS NOT CG APPROVED.
Condition: Unknown
Due 3 June 1987
Resolved 3 June 1987
Unknown
Issued 3 June 1987 Resolved
PROVIDE FUEL SHUT-OFF VALVE ADJACENT TO FUEL FILTERS ON PORT & STBD MAIN ENGINE DIESEL.
Condition: Unknown
Due 3 June 1987
Resolved 3 June 1987
Unknown
Issued 3 June 1987 Resolved
INSTALL FIXED BILGE SYSTEM IN ACCORDANCE WITH 46CFR182.25.
Condition: Unknown
Due 3 June 1987
Resolved 3 June 1987
Unknown
Issued 3 June 1987 Resolved
PROVIDE BRACKETS FOR FIRE EXTINGUISHERS.
Condition: Unknown
Due 3 June 1987
Resolved 3 June 1987

Ownership record