Documentation record
Registered dimensions (L × B × D)63.0 ft × 15.8 ft × 7.4 ft
Registered tonnagegross 56 / net 50
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHENRY C. GREBE, BUILDER · CHICAGO, IL, UNITED STATES · built 1950
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBOSTON, MA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 13 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it56 - Regulatory (Subpart C or D), Gross Ton
50 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
19 inspections, each with its date, unit and type; 13 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 19
23 March 2026
Internal Structural Exam · Vessel Attendance · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8329985
25 November 2025
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8273408
1 October 2025
Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8244379
12 February 2025
Plan Review "T" Boat
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8079301
19 December 2024
Deficiency Check · Examination of Repairs · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8062657
10 October 2024
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8017147
27 June 2024
Plan Review "T" Boat · Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7924180
5 March 2024
Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7875460
14 September 2023
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7757360
22 September 2022
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7564044
30 March 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7601025
28 October 2021
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7341387
4 June 2021
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7215626
2 November 2020
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7088260
10 March 2020
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6925635
8 October 2019
Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6831648
4 July 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6741388
8 February 2018
Simplified Stability Test · Drydock Exam · In-Service Inspection · Internal Structural Exam · Plan Review "T" Boat · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6542276
22 April 2016
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5859406
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 27 June 2024
Resolved
During 'New to Zone' inspection: Inside engineroom, on port side hull, the 2nd transverse wood frame aft of the forward engineroom watertight bulkhead (located directly behind the E/R door entrance): this frame was found cracked in 2 places, in way of the 2 fasteners just above the gusset. See MISLE activity for picture/location of cracked frame. Before repairs are conducted, the owner shall contact the local USCG OCMI and submit a repair plan proposal for acceptance. Until this deficiency is cleared, the vessel is restricted to a river's route not more than 1000' from shore, or must be completed before 01 DEC 2024: whichever comes first.
46 CFR 176.25-5(a)(1)
(OLD SUBCHAPTER T) CODE 705C
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2024
Resolved 31 January 2025
Resolution: resolved by 8062657
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 27 June 2024
Resolved
During 'New to Zone' inspection: Inside engineroom, 2' section of keelson found decaying and wet rotted through 80%. Location: where the aluminum vertical deck support column interfaces with the keelson in the aft 3/4 of the engineroom between the two main engines. See MISLE activity for picture/location of the rot. Before repairs are conducted, the owner shall contact the local USCG OCMI and submit a repair plan proposal for acceptance. Until this deficiency is cleared, the vessel is restricted to a river's route not more than 1000' from shore, or must be completed before 01 DEC 2024: whichever comes first.
46 CFR 176.25-5(a)(1)
(OLD SUBCHAPTER T)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 December 2024
Resolved 31 January 2025
Resolution: Rot was cleaned out and treated with borax. Special note added to continue monitoring. Vessel placed on annual dry dock schedule.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 27 June 2024
Resolved
Found diesel fuel leak from the discharge fitting from the secondary fuel oil filer serving the generator.
46 CFR 176.25-10(a)(4) (old T)
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 27 June 2024
Resolved 3 July 2024
Resolution: Fitting tightened, observed no leaks.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 27 June 2024
Resolved
Found diesel fuel leak from ball valve fitting just before entering the fuel/water separator serving the generator.
46 CFR 176.25-10(a)(4) (old t)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 June 2024
Resolved 3 July 2024
Resolution: Fitting tightened, does not leak.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 27 June 2024
Resolved
Found diesel fuel leak from the overflow crossover ball valve in the aft overhead space of the engineroom. 46 CFR 176.25-10(a)(1) (old t)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 June 2024
Resolved 3 July 2024
Resolution: Fitting tightened, does not leak.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 June 2024
Resolved
Found battery acid leaking from forward 24V battery located centerline in the engineroom. 46 CFR 176.25-10(a)(4)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 June 2024
Resolved 3 July 2024
Resolution: Battery cleaned, re-charged and did not leak.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 March 2024
Resolved
Nothing in the part shall be construed as limiting the marine inspector from making such tests or inspections as reasonable and practicable to be assured of the seaworthiness of the vessel. Prior to carrying passengers, make vessel available to Coast Guard Marine Inspector for sea trial.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 April 2024
Resolution: Vessel completed satisfactory sea trial for CG's review/approval.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 March 2024
Resolved
Provisions must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. Identified open bulkhead penetrations in the forward and aft engine room bulk heads, shaft penetrations, starboard aft corner ladder connecting to the operators console and in way of vessel side shell and deck cable penetrations.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 April 2024
Resolution: Vessel made alterations to engine space to ensure its vapor tight integrity. MI conducted a satisfactory light test in the compartment.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 March 2024
Resolved
Irrespective of build date, a vessel to which this subchapter applies must meet 46 CFR 181.405, 181.450, 181.500, 185.364, and 185.420(b), if it is not a ferry, and if it, (1) Has overnight accommodations for passengers. Vessel is identified as a Cover Small Passenger vessel due having sleeping accommodations below deck. Propose plan forward IAW CG-CVC PL 23-03.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2024
Resolution: added the following verbiage to COI PASSENGERS ARE PROHIBITED ACCESS TO OVERNIGHT ACCOMMODATION SPACES. Attending MI witnessed proper signage for each "crew only" spaces.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 September 2022
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Grab lines on ring life buoy wasted & worn. Lettering for the vessel's name was peeling and requires renewal. Owner operator shall provide photo of the renewed ring life buoy.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 October 2022
Resolved 28 September 2022
Resolution: Provided documentation attesting to the renewal of the vessels ring life buoy.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 22 September 2022
Resolved
Fuel shutoff valves shall be installed so as to close against the fuel flow, fitted in the fuel supply lines one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. During the inspection port and starboard fuel tank remote shut off vale(s) were seized/inoperable and unable to be secured from the remote pull station. Vessel owner/operator shall provide an alternative procedure to keep main fuel tanks secured while u/w carrying passengers and just run on the day tank until permanent repairs are made. Submit the above plan upon receipt of this report. Within 14 days provide photographic documentation for our records attesting to adequate repairs rendering both remote operated fuel shut off vales fully operational & free of binding.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 October 2022
Resolved 28 September 2022
Resolution: Recieved documentation attesting to the proper operation of the vessels remote fuel shut off valve arrangement.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 8 October 2019
Resolved
Found that emergency exits were not marked IAW 46 CFR 185.606 “All means used as emergency escapes shall be marked EMERGENCY EXIT, KEEP CLEAR in 50mm letters.”
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 October 2019
Resolved 22 October 2019
Resolution: Recieved picture proof of corrected deficiency
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 October 2019
Resolved
The retro-reflective tape on numerous life jackets were found to be disintegrated. Deficiency issues to check entire inventory of life-jackets and replace IAW 46 CFR 185.604(h) type one retro-reflective tape.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 October 2019
Resolved 22 October 2019
Resolution: Recieved picture proof of corrected deficiency