Records from 2004 to 2026. Most recent: inspection, 13 January 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 22
13 January 2026
Annual Inspection · Deficiency Check
Physical examination · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 8295345
10 December 2024
Annual Inspection · Hull Examination
Physical examination · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 8045336
25 January 2024
Hull Examination · COI Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7856397
3 February 2023
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7631826
21 January 2022
Drydock Exam · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7384920
29 March 2021
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7165654
4 December 2020
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7106433
24 January 2020
Annual Inspection · Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6895829
28 January 2019
COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6616264
15 February 2018
Annual Inspection · DAPI Audit · Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6351357
15 February 2017
DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6089894
9 February 2016
Hull Examination · Internal Structural Exam · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5812353
8 February 2011
Hull Examination · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3941856
15 March 2010
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3696348
13 January 2009
COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3393474
13 March 2008
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3163857
28 February 2008
Hull Examination · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3155612
31 January 2007
Annual Inspection · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2865028
5 March 2006
Annual Inspection · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2596172
28 April 2005
Annual Inspection · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2353170
3 March 2004
Plan Review "T" Boat · Construction Oversight
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2017270
26 February 2004
Initial Certification · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2014166
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 13 January 2026
Resolved
A vessel must comply with the applicable requirements for Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR 80. EPIRB number did not match the NOAA registration. Provide EPIRB with matching NOAA registration.
46 CFR 184.502
Action required: 10 - Deficiency Rectified
Resolved 13 January 2026
Resolution: Correct EPIRB provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 January 2026
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment under all practicable conditions. The handle/rod for manual bilge pump not on the vessel. Provide the handle/rod for the manual bilge pump.
46 CFR 182.500(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2026
Resolved 8 February 2026
Resolution: Pump handle provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 January 2026
Resolved
The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant OCMI, but must be not less than the minimum number required by table 46 CFR 181.500(a) Vessel missing 01 10-B:C at operating station. Provide 01 portable extinguisher.
46 CFR 181.500(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2026
Resolved 8 February 2026
Resolution: Portable fire extinguisher provided.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 13 January 2026
Resolved
All equipment must be installed and maintained in such a manner as to afford adequate protection from personal injury. T-top has broken free from frame on port side forward mounting location. Provide repair to make t-top secure to mounting location.
46 CFR 182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2026
Resolved 8 February 2026
Resolution: T-top repaired.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 January 2026
No resolution recorded
The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant [name withheld] system has been modified. Provide amended electrical drawings for approval.
46 CFR 176.700
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2026 — due date passed with no resolution recorded
Communications › Radio Communications › VHF Radiotelephone
Issued 5 March 2006
Resolved
Provide valid FCC Safety Certificate.
Condition: Unknown
Due 15 March 2006
Resolved 20 March 2007