MAURY USCG vessel records Sign in
← All vessels

CARIBBEAN SPIRIT

CARIBBEAN SPIRIT is a 2004 tank ship. The Coast Guard has recorded 21 inspections since 2004, most recently in January 2021, along with 6 deficiencies and 2 operational controls.

Records from 2004 to 2021. Most recent: inspection, 24 January 2021.

Built
2004
Last inspected
24 January 2021
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9278698 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
670324
Flag
PANAMA
—
Maury page id
psix-670324

Inspections, by type

…with no type recorded5
Years with a record 12 calendar years (2004–2021)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it30636 - Convention (Subpart B), Gross Ton
11468 - Convention (Subpart B), Net Ton
46383 - Dead Weight, Ton
56460 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 21

24 January 2021 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7126850
23 June 2020 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6984493
18 April 2018 PII Safety Exam · Deficiency Check · ISPS II Exam · COC-CHEM Renew · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6391152
31 March 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6115102
31 March 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6115115
29 March 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6113452
29 March 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6113454
29 June 2016 ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5922947
9 February 2010 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3677808
28 December 2009 MARPOL Annex I Examination · MARPOL Annex II Examination · MARPOL Annex VI Survey · COC-CHEM Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3654182
7 October 2008 MARPOL Annex V Examination · ISPS II Exam · COC-TVE Annual · STCW 95 Exam · ISM Exam · Ballast Water Examination · MARPOL Annex I Examination · Administrative Inspection · Loadline Exam · ILO-147 Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3340154
2 October 2008 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3337353
13 December 2007 COC-TVE Renew · COC-CHEM Renew · MARPOL Annex I Examination · MARPOL Annex V Examination · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3105301
9 May 2007 COC-CHEM Annual · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2926514
19 July 2006 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2718316
13 March 2006 COC-TVE Renew
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2601460
20 July 2005 COC-TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2433113
22 July 2004 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2135629
20 July 2004 ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2139701
4 March 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2022755
2 March 2004 Certificate of Compliance · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2016818

Deficiency record · 6

07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 23 June 2020 Resolved
The machinery and associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. PSCO observed hole (approx. 2 inches) in the General Service line IVO frame 106. General Service line unable to provide water to 05 fire hydrants and anchor wash.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 24 June 2020
Resolution: Temporary repairs made through the application of DEVCON and metal clamp. GS Line tightness tested to 7Kg/cm2. Class survey provided
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 23 June 2020 Resolved
A ship of 1600 gross tons or more constructed after June 30, 1974 must have a fixed container or enclosed deck area under or around each fuel oil or bulk lubricating oil tank vent, overflow, and fill pipe, that has a capacity of one barrel. PSCO observed multiple holes in port and starboard fuel tank vent containment. 33CFR155.320(a)(2)/16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 June 2020
Resolution: Holes in vent containment were plugged or repaired with DEVCON as needed.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 18 April 2018 Resolved
1150 - Loading and Unloading Equipment - Each vessel vapor connection flange face must have a permanent stud projecting outward that has a 12.7 mm (0.5 in) diameter and is at least 25.4 mm (1 in) long. Vessel missing stbd manifold stud, and port maniforl stud appears to be removable. - 46 CFR 39.2001(j) - Prior to next US port after sailing foreign
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 May 2018
Resolution: NKK Class report verified permanent studs were properly welded to the VCS flanges.
Documentation › Certificates/Documents › Cargo Ship Safety Equipment Certificate
Issued 28 December 2009 Resolved
0110- Cargo Ship Safety Equipment Certificate- During the inspection of the ship's certificates, the PSCO observed that the Cargo Safety Equipment Certificate was not endorsed for LRIT. The Cargo Safety Radio Certificate was issued 26 Feb 2009, therefore the Cargo Safety Equipment Certificate must be endorsed to reflect that LRIT was provided. SOLAS 2004 Consolidated I/8.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 28 December 2009
Resolved 9 February 2010
Resolution: Received Cargo Ship Safety Equipment Certificate and Form E satisfying the requirements.
Lifesaving › Lifebuoys › Immediately Available
Issued 13 March 2006 Resolved
Life Bouys permanently secured with shackles. At least one had rusted and could not be opened by hand. 10c
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 13 March 2006
Resolution: All shackles were removed.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 13 March 2006 Resolved
Fire door in main stairwell (A0O door) does not self latch. 70a
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 19 July 2006
Resolution: Inspected door, minor adjustments were made by the crew and I found the door in good working order and cleared the deficiency.

Ownership record