CHEMBULK YOKOHAMA

CHEMBULK YOKOHAMA is a 2003 tank ship. The Coast Guard has recorded 17 inspections since 2016, most recently in October 2019, along with 34 deficiencies and 5 operational controls.

Records from 2016 to 2019. Most recent: inspection, 5 October 2019.

Built
2003
Last inspected
5 October 2019
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 5 October 2019
…with no type recorded7
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2016–2019)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9276248
670510
Flag
MARSHALL ISLANDS
Maury page id
psix-670510

Documentation record

Tonnage as PSIX records it11573 - Simplified, Gross Ton
11573 - Convention (Subpart B), Gross Ton
6084 - Simplified, Net Ton
6084 - Convention (Subpart B), Net Ton
21181 - Dead Weight, Metric Ton
26468 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 17

5 October 2019 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6828984
20 May 2019 COC-CHEM & TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6688343
21 April 2019 In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6667023
21 April 2019 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6667746
18 April 2019 ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6665079
2 July 2018 COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6464058
7 June 2018 In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6436715
26 September 2017 Ballast Water Examination · COC-CHEM Annual · COE-Administrative · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6274285
10 June 2017 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6171245
2 June 2017 COE-Dockside
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6163551
12 February 2017 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6086852
11 February 2017 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6086473
2 October 2016 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6013189
1 October 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6013686
8 July 2016 ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5930181
6 July 2016 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5931485
14 April 2016 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5855399

Deficiency record · 34

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 April 2019 Resolved
74 SOLAS (14) I/II 17ac The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The vessel experienced an equipment failure while transiting the navigable waters of the United States which adversely impacted its fitness and capability to safely maneuver the Port of Boston.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 April 2019
Resolved 22 April 2019
Resolution: Class report received
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 7 June 2018 Resolved
0986-Bulkheads, operational damage- The condition of the ship shall conform with the provisions of the present regulations. Vessel reported heavy fuel oil on stbd anchor chain coming from 1 center heavy fuel tank. Vessel must submit repair plan with concurrence from Administration prior to departure. SOLAS 74 (a) 2014 Cons. I/11 (a) 17ab
Action required: 17 - Rectify deficiencies prior to departure
Due 7 June 2018
Resolved 2 July 2018
Resolution: Vessel submitted documentation and PSCO's observed repairs.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 2 October 2016 Resolved
0611-Lifeboat Inventory- Lifeboat shall consist of food ration totaling 10,000kj for each person the lifeboat is permitted to accommodate. PSCO Observed 04 rations out of 25 on port side lifeboat and 03 rations out of 25 on starboard side lifeboat were compromised. SOLAS III/34 LSA IV/4.4.8.12 - 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 October 2016
Resolution: Replacement lifeboat rations received on board vessel as evident by receipt and statement from Master and Agent.
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 2 October 2016 Resolved
1830-Cargo Transfer- Tank overfill control system shall give visual and audible tank overflow alarm. PSCO observed crew was unable to prove proper operation of overflow alarms on any of the cargo tanks. -SOLAS VII/10.1 IBC 15.19.7- Prior to cargo
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 June 2017
Resolution: PSC NOLA received a class report from DNV-GL satisfying the requirement.
Deck/Cargo › Holds/Tanks › Tank Pressure Monitoring Device
Issued 2 October 2016 Resolved
1830-Cargo Transfer- Pressure sensors fitted in each tank shall also provide alarm. PSCO observed that crew was unable to prove proper operation of any tank pressure alarm -SOLAS VII/10.1 IBC 8.3.3- Prior to Cargo
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 June 2017
Resolution: PSC NOLA received a class report from DNV-GL satisfying the requirement.
Deck/Cargo › Cargo Stowage › General
Issued 2 October 2016 Resolved
1836-Temperature Control-Means shall be provided for measuring cargo temperature. An alarm system shall be provided. PSCO observed that crew was unable to prove proper operation of high temp alarms. -SOLAS VII/10.1 IBC 7.1.5- Prior to Cargo which requires high temp alarms.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 June 2017
Resolution: PSC NOLA received a class report from DNV-GL satisfying the requirement.
Fire Fighting › Miscellaneous Items › Materials for Overboard Outlets
Issued 2 October 2016 Resolved
0750-Fire Prevention- 04 Flame screens on HFO bunkering stations were found missing, wasted, or otherwise inoperable. -SOLAS II-2/15.2- Rectify within 7 days.
Due 9 October 2016
Resolved 10 June 2017
Resolution: PSC NOLA received a class report from DNV-GL satisfying the requirement.
Documentation › Safety Management System › Company Responsibility/Authority Documentation
Issued 2 October 2016 Resolved
2550-Maintenance of Ship and Equipment- PSCO observed numerous discrepancies that were previously identified during COC exam 3 months earlier. Same master and officers present -SOLAS IX/3.1 ISM 10.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 10 June 2017
Resolution: PSC NOLA received a class report from DNV-GL satisfying the requirement.
Operations/Management › Pollution › Control of Garbage
Issued 2 October 2016 Resolved
2120-Garbage-PSCO observed vessel's garbage management plan does not specify garbage storage locations & sizes, ship specific collection procedures or garbage equipment on board. -MARPOL V/10- 10c
Condition: Improper/Lack of Maintenance
Due 16 October 2016
Resolved 2 October 2016
Resolution: Vessel updated garbage management plan to include ship specific information.
Operations/Management › Mandatory Ship Reporting Systems › Entry Report
Issued 11 July 2016 Resolved
Vessel failed to immediately report a hazardous condition to the US Coast Guard prior to arrival in the Port of Houston, TX.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 13 July 2016
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 8 July 2016 Resolved
FIRE DAMPERS WERE INOPERABLE AND HAD POST INSTALLATION ALTERATIONS IN BOTH MACHINERY AND ACCOMMODATION SPACES. 74SOLAS(01CONS.)II-2/16.11.1 30ABC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 July 2016
Resolution: Verified rectified by USCG Marine Inspector. See attached Classification Society Report. See MISLE case 5930181.
Fire Fighting › Fire Hoses › Condition
Issued 8 July 2016 Resolved
FIRE FIGHTING HOSES WERE FOUND IN MACHINERY SPACES AND ON DECK WITH DRY ROTTED O-RINGS AND UNSERVICEABLE FITTINGS. FIRE EXTINGUISHERS WERE NOT INSPECTED WITHIN THE PAST 3 MONTHS. 74SOLAS(01CONS.)II-2/21 74SOLAS(01CONS.)II-2/4.6.1 74SOLAS(01CONS.)II-2/4.7.1 74SOLAS(01CONS.)II-2/6.5 30ABC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 July 2016
Resolution: Verified rectified by USCG Marine Inspector. See attached Classification Society Report. See MISLE case 5930181.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 8 July 2016 Resolved
OVER 10 A-0 BOUNDARIES COMPROMISED WITH HOLD BACKS ON REQUIRED SELF CLOSING DOORS. 74SOLAS(01CONS.)II-2/47.2 30ABC
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 July 2016
Resolution: Verified rectified by USCG Marine Inspector. See attached Classification Society Report. See MISLE case 5930181.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 8 July 2016 Resolved
EXTENSION CORD LEADING FROM EMERGENCY GENERATOR ROOM OUT AN A-0 BOUNDARY DOOR THROUGH A PASSAGEWAY, AND INTO ANOTHER A-0 BOUNDARY DOOR CONNECTED TO VENTILATION FAN TO COOL REFRIGERATION UNITS. EXTENSION CORD DOES NOT ALLOW FOR SELF CLOSING DOORS TO CLOSE AND SEAL PROPERLY. 74SOLAS(01CONS.)II-2/47.1 74SOLAS(04CONS)II-1/35 30ABC
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 July 2016
Resolution: Verified rectified by USCG Marine Inspector. See attached Classification Society Report. See MISLE case 5930181.
Fire Fighting › Miscellaneous Items › Materials for Overboard Outlets
Issued 8 July 2016 Resolved
FLAME SCREENS ON HFO BUNKERING STATION WERE FOUND TO BE WASTED AND/OR MISSING. ADDITIONALLY, THE VALVE HANDLES ON PORT AND STARBOARD BUNKERING STATIONS WERE STRIPPED, WASTED, AND INOPERABLE. 74SOLAS(01CONS.)II-2/15.2 30ABC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 July 2016
Resolution: Verified rectified by USCG Marine Inspector. See attached Classification Society Report. See MISLE case 5930181.
Lifesaving › Inflatable Liferafts › Painter
Issued 8 July 2016 Resolved
STARBOARD LIFE RAFT PAINTER WAS ATTACHED TO CRADLE AND NOT TO THE WEAK LINK PREVENTING IT FROM BEING FREE FLOATING. 74SOLAS(14)III/34 LSA CODE A IV/4.1.6.1 30ABC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 July 2016
Resolution: Verified rectified by USCG Marine Inspector. See attached Classification Society Report. See MISLE case 5930181.
Lifesaving › Lifeboat › Rudder/Tiller/Steering
Issued 8 July 2016 Resolved
PORT AND STARBOARD LIFEBOAT RUDDER MOUNTS WARPED APPROXIMATELY 2 DEGREES DUE TO IMPROPER SECURING. 74SOLAS(14)III/34 LSA CODE A IV/4.4.7.2 30ABC
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 July 2016
Resolution: Verified rectified by USCG Marine Inspector. See attached Classification Society Report. See MISLE case 5930181.
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 8 July 2016 Resolved
ALL AUDIBLE & VISUAL HIGH LEVEL ALARMS ON DECK WERE INOPERABLE. MULTIPLE HIGH LEVEL & OVERFILL ALARMS BOTH AUDIBLY AND VISUALLY, INOPERABLE IN THE CARGO CONTROL ROOM. 46CFR39.2007( C)(3) 74SOLAS(14)VII/10.1 IBC CODE 15.19.6 IBC CODE 15.19.7.2 30ABC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 July 2016
Resolution: Verified rectified by USCG Marine Inspector. See attached Classification Society Report. See MISLE case 5930181.
Accommodation/Occupational Safety › Ventilation › General
Issued 8 July 2016 Resolved
ATMOSPHERIC CONDITIONS INSIDE STEERING GEAR ROOM FOUND TO BE OF LOW OXYGEN CONTENT. VENTILATION FAN ON FANTAIL FOUND TO BE INOPERABLE. 74SOLAS(04CONS)II-1/35 30ABC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 July 2016
Resolution: Verified rectified by USCG Marine Inspector. See attached Classification Society Report. See MISLE case 5930181.
Fire Fighting › Fixed Deck Foam System › Valves
Issued 8 July 2016 Resolved
FOAM LINE ISOLATION VALVE SEIZED. 74SOLAS(01CONS)II-2/61.9 30ABC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 July 2016
Resolution: Verified rectified by USCG Marine Inspector. See attached Classification Society Report. See MISLE case 5930181.
Engineering › Compressed Air System (control) › Valve
Issued 8 July 2016 Resolved
THE DATA PLATE ON THE AIR PRESSURE SYSTEM RELIEF VALVE WAS ILLEGIBLE. 74SOLAS(04CONS)II-1/34.1 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 July 2016
Resolution: Verified rectified by USCG Marine Inspector. See attached Classification Society Report. See MISLE case 5930181.
Fire Fighting › Self-contained Breathing Apparatus › Air Supply (minutes)
Issued 8 July 2016 Resolved
DISPLAYED CERTIFICATE FOR AIR COMPRESSOR USED FOR REFILLING SCBA BOTTLES EXPIRED IN 2015. 74SOLAS(14)VII/10.1 IBC CODE 14.2.6 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 July 2016
Resolution: Verified rectified by USCG Marine Inspector. See attached Classification Society Report. See MISLE case 5930181.
Engineering › Freshwater System (air cooling) › Piping
Issued 8 July 2016 Resolved
FRESHWATER GENERATOR, AIR CONDITIONING SUPPLY MAIN, TOILET SUPPLY PIPE LEAKING DUE TO CORROSION ON PIPE, SOFT PATCH INSTALLED. 74SOLAS(04CONS)II-1/26.1 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 July 2016
Resolution: Verified rectified by USCG Marine Inspector. See attached Classification Society Report. See MISLE case 5930181.
Communications › Internal Communications System › Sound-powered Telephone
Issued 8 July 2016 Resolved
EMERGENCY COMMUNICATIONS FROM REMOTE ENGINE CONTROL STATION NON-EXISTENT. 74SOLAS(04CONS)II-1/37.1 74SOLAS(04CONS)37.2 17AC
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 July 2016
Resolution: Verified rectified by USCG Marine Inspector. See attached Classification Society Report. See MISLE case 5930181.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 8 July 2016 Resolved
FRAMO POWER PACK ELECTRICAL PANEL HAS BROKEN NON-CONDUCTIVE GRAB RAIL. 74SOLAS(04CONS)II-1/45.1.3 17AC
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 July 2016
Resolution: Verified rectified by USCG Marine Inspector. See attached Classification Society Report. See MISLE case 5930181.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 8 July 2016 Resolved
BONDING STRAPS MISSING OR INADEQUATE. 74SOLAS(14)VII/10.1 IBC CODE 10.2 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 July 2016
Resolution: Verified rectified by USCG Marine Inspector. See attached Classification Society Report. See MISLE case 5930181.
Engineering › Pressure Vessel › Piping
Issued 8 July 2016 Resolved
FRAMO PUMP HYDRAULIC LINE ISOLATION VALVE SEIZED AND INOPERABLE. 74SOLAS(04CONS)II-1/26.1 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 July 2016
Resolution: Verified rectified by USCG Marine Inspector. See attached Classification Society Report. See MISLE case 5930181.
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 8 July 2016 Resolved
TANK 7 STARBOARD TEMPERATURE SENSOR IS INOPERABLE. 74SOLAS(14)VII/10.1 IBC CODE 7.1.5 17AC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 July 2016
Resolution: Verified rectified by USCG Marine Inspector. See attached Classification Society Report. See MISLE case 5930181.
Deck/Cargo › Holds/Tanks › Tank Pressure Monitoring Device
Issued 8 July 2016 Resolved
TANK 7 STARBOARD PRESSURE MONITORING SYSTEM INOPERABLE. 74SOLAS(14)VII/10.1 IBC CODE 8.3.3 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 July 2016
Resolution: Verified rectified by USCG Marine Inspector. See attached Classification Society Report. See MISLE case 5930181.
Deck/Cargo › Holds/Tanks › Ullage
Issued 8 July 2016 Resolved
TANK 7 STARBOARD UNABLE TO MEASURE ULLAGE. 74SOLAS(14)VII/10.1 IBC CODE 13.1.1 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 July 2016
Resolution: Verified rectified by USCG Marine Inspector. See attached Classification Society Report. See MISLE case 5930181.
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 8 July 2016 Resolved
GLAND SEAL LEAKAGE AND MOTOR WIRING NOT INSTALLED PROPERLY ON EMERGENCY FIRE PUMP. 74SOLAS(01CONS) II-2/21 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 July 2016
Resolution: Verified rectified by USCG Marine Inspector. See attached Classification Society Report. See MISLE case 5930181.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 8 July 2016 Resolved
FIRE CONTROL PLAN DOES NOT LIST SELF CLOSING DOORS. 74SOLAS(01CONS) II-2/20.1 17AC
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 July 2016
Resolution: Verified rectified by USCG Marine Inspector. See attached Classification Society Report. See MISLE case 5930181.
Construction/Loadline › Markings › Load Line Mark
Issued 8 July 2016 Resolved
THE LOAD LINE WAS NOT PAINTED IN CONTRASTING COLORS. 66 ICLL I/8 40AC
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 July 2016
Resolution: Verified rectified by USCG Marine Inspector. See attached Classification Society Report. See MISLE case 5930181.
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 8 July 2016 Resolved
FOUND VESSEL TO BE SUBSTANDARD AND NONCONFORMING WITH THE APPLICABLE CONVENTIONS REGULATING THE VESSEL. 74SOLAS(14)IX/3.1 ISM PART A10.1
Action required: 705 - Other - as specified
Resolved 11 July 2016
Resolution: Verified rectified by USCG Marine Inspector. See attached Classification Society Report. See MISLE case 5930181.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.