← All vessels
CHEMBULK YOKOHAMA
CHEMBULK YOKOHAMA is a 2003 tank ship. The Coast Guard has recorded 47 inspections since 2004, most recently in October 2019, along with 39 deficiencies and 17 operational controls, 1 with no removal date recorded.
Records from 2004 to 2019. Most recent: inspection, 5 October 2019.
- Built
- 2003
- Last inspected
- 5 October 2019
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 39 recorded · 0 without a recorded resolution
- Controls
- 1 with no removal date recorded
Identity
9276248 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7OQ3
670510
Flag
MARSHALL ISLANDS
—
Maury page id
psix-670510
Inspections, by type
…with no type recorded22
Years with a record
14 calendar years (2004–2019)
The 47 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it11573 - Simplified, Gross Ton
11573 - Convention (Subpart B), Gross Ton
6084 - Simplified, Net Ton
6084 - Convention (Subpart B), Net Ton
21181 - Dead Weight, Metric Ton
26468 - Displacement, Metric Ton
11573 - Convention (Subpart B), Gross Ton
6084 - Simplified, Net Ton
6084 - Convention (Subpart B), Net Ton
21181 - Dead Weight, Metric Ton
26468 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 47
5 October 2019
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6828984
20 May 2019
COC-CHEM & TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6688343
21 April 2019
In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6667023
21 April 2019
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6667746
18 April 2019
ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6665079
2 July 2018
COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6464058
7 June 2018
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6436715
26 September 2017
Ballast Water Examination · COC-CHEM Annual · COE-Administrative · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6274285
10 June 2017
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6171245
2 June 2017
COE-Dockside
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6163551
12 February 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6086852
11 February 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6086473
2 October 2016
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6013189
1 October 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6013686
8 July 2016
ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5930181
6 July 2016
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5931485
14 April 2016
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5855399
15 December 2015
ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5782207
6 August 2015
NPV Safety Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5213906
5 August 2015
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5213939
13 July 2015
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5182866
20 May 2014
ISPS II Exam · COE-Dockside · Ballast Water Examination · COC-CHEM Renew
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4858251
15 May 2014
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4859261
19 September 2011
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4149204
20 January 2011
COC-CHEM Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3929747
31 October 2010
MARPOL Annex V Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3881673
30 October 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3877128
18 January 2010
Ballast Water Examination · MARPOL Annex VI Survey · MARPOL Annex II Examination · MARPOL Annex I Examination · COC-CHEM Renew · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3663425
17 January 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3663870
14 January 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3664168
30 July 2009
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3550620
22 July 2009
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3542675
6 April 2009
Administrative Inspection
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 3447077
3 February 2009
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3411868
23 January 2009
PII Safety Exam · Ballast Water Examination · COC-CHEM Annual · ISPS II Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3399108
12 November 2008
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3368748
16 August 2008
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3299922
7 March 2008
Ballast Water Examination · MARPOL Annex I Examination · ISPS III Exam · MARPOL Annex V Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3156756
27 December 2007
MARPOL Annex V Examination · MARPOL Annex I Examination · ISPS II Exam · COC-CHEM Renew · Ballast Water Examination · MARPOL Annex II Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3120401
4 October 2007
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3073128
26 January 2007
ISPS II Exam · COC-CHEM Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2862327
8 August 2006
ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2740095
24 February 2006
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2591522
18 November 2005
COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2535655
5 March 2004
Ballast Water Examination · Certificate of Compliance · Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2017944
4 March 2004
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2018652
4 March 2004
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2035547
Deficiency record · 39
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 April 2019
Resolved
74 SOLAS (14) I/II 17ac
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board.
The vessel experienced an equipment failure while transiting
the navigable waters of the United States which adversely
impacted its fitness and capability to safely maneuver the Port of Boston.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 7 June 2018
Resolved
0986-Bulkheads, operational damage- The condition of the ship shall conform with the provisions of the present regulations. Vessel reported heavy fuel oil on stbd anchor chain coming from 1 center heavy fuel tank. Vessel must submit repair plan with concurrence from Administration prior to departure. SOLAS 74 (a) 2014 Cons. I/11 (a) 17ab
Lifesaving › Lifeboat Equipment › Food Ration
Issued 2 October 2016
Resolved
0611-Lifeboat Inventory- Lifeboat shall consist of food ration totaling 10,000kj for each person the lifeboat is permitted to accommodate. PSCO Observed 04 rations out of 25 on port side lifeboat and 03 rations out of 25 on starboard side lifeboat were compromised. SOLAS III/34 LSA IV/4.4.8.12 - 17ac
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 2 October 2016
Resolved
1830-Cargo Transfer- Tank overfill control system shall give visual and audible tank overflow alarm. PSCO observed crew was unable to prove proper operation of overflow alarms on any of the cargo tanks. -SOLAS VII/10.1 IBC 15.19.7- Prior to cargo
Deck/Cargo › Holds/Tanks › Tank Pressure Monitoring Device
Issued 2 October 2016
Resolved
1830-Cargo Transfer- Pressure sensors fitted in each tank shall also provide alarm. PSCO observed that crew was unable to prove proper operation of any tank pressure alarm -SOLAS VII/10.1 IBC 8.3.3- Prior to Cargo
Deck/Cargo › Cargo Stowage › General
Issued 2 October 2016
Resolved
1836-Temperature Control-Means shall be provided for measuring cargo temperature. An alarm system shall be provided. PSCO observed that crew was unable to prove proper operation of high temp alarms. -SOLAS VII/10.1 IBC 7.1.5- Prior to Cargo which requires high temp alarms.
Fire Fighting › Miscellaneous Items › Materials for Overboard Outlets
Issued 2 October 2016
Resolved
0750-Fire Prevention- 04 Flame screens on HFO bunkering stations were found missing, wasted, or otherwise inoperable. -SOLAS II-2/15.2- Rectify within 7 days.
Documentation › Safety Management System › Company Responsibility/Authority Documentation
Issued 2 October 2016
Resolved
2550-Maintenance of Ship and Equipment- PSCO observed numerous discrepancies that were previously identified during COC exam 3 months earlier. Same master and officers present -SOLAS IX/3.1 ISM 10.1
Operations/Management › Pollution › Control of Garbage
Issued 2 October 2016
Resolved
2120-Garbage-PSCO observed vessel's garbage management plan does not specify garbage storage locations & sizes, ship specific collection procedures or garbage equipment on board. -MARPOL V/10- 10c
Operations/Management › Mandatory Ship Reporting Systems › Entry Report
Issued 11 July 2016
Resolved
Vessel failed to immediately report a hazardous condition to the US Coast Guard prior to arrival in the Port of Houston, TX.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 8 July 2016
Resolved
FIRE DAMPERS WERE INOPERABLE AND HAD POST INSTALLATION ALTERATIONS IN BOTH MACHINERY AND ACCOMMODATION SPACES. 74SOLAS(01CONS.)II-2/16.11.1 30ABC
Fire Fighting › Fire Hoses › Condition
Issued 8 July 2016
Resolved
FIRE FIGHTING HOSES WERE FOUND IN MACHINERY SPACES AND ON DECK WITH DRY ROTTED O-RINGS AND UNSERVICEABLE FITTINGS. FIRE EXTINGUISHERS WERE NOT INSPECTED WITHIN THE PAST 3 MONTHS. 74SOLAS(01CONS.)II-2/21
74SOLAS(01CONS.)II-2/4.6.1
74SOLAS(01CONS.)II-2/4.7.1
74SOLAS(01CONS.)II-2/6.5 30ABC
Fire Fighting › Structural - A Class Divisions › Doors
Issued 8 July 2016
Resolved
OVER 10 A-0 BOUNDARIES COMPROMISED WITH HOLD BACKS ON REQUIRED SELF CLOSING DOORS. 74SOLAS(01CONS.)II-2/47.2 30ABC
Fire Fighting › Structural - A Class Divisions › Doors
Issued 8 July 2016
Resolved
EXTENSION CORD LEADING FROM EMERGENCY GENERATOR ROOM OUT AN A-0 BOUNDARY DOOR THROUGH A PASSAGEWAY, AND INTO ANOTHER A-0 BOUNDARY DOOR CONNECTED TO VENTILATION FAN TO COOL REFRIGERATION UNITS. EXTENSION CORD DOES NOT ALLOW FOR SELF CLOSING DOORS TO CLOSE AND SEAL PROPERLY. 74SOLAS(01CONS.)II-2/47.1
74SOLAS(04CONS)II-1/35 30ABC
Fire Fighting › Miscellaneous Items › Materials for Overboard Outlets
Issued 8 July 2016
Resolved
FLAME SCREENS ON HFO BUNKERING STATION WERE FOUND TO BE WASTED AND/OR MISSING. ADDITIONALLY, THE VALVE HANDLES ON PORT AND STARBOARD BUNKERING STATIONS WERE STRIPPED, WASTED, AND INOPERABLE. 74SOLAS(01CONS.)II-2/15.2 30ABC
Lifesaving › Inflatable Liferafts › Painter
Issued 8 July 2016
Resolved
STARBOARD LIFE RAFT PAINTER WAS ATTACHED TO CRADLE AND NOT TO THE WEAK LINK PREVENTING IT FROM BEING FREE FLOATING. 74SOLAS(14)III/34 LSA CODE A IV/4.1.6.1 30ABC
Lifesaving › Lifeboat › Rudder/Tiller/Steering
Issued 8 July 2016
Resolved
PORT AND STARBOARD LIFEBOAT RUDDER MOUNTS WARPED APPROXIMATELY 2 DEGREES DUE TO IMPROPER SECURING. 74SOLAS(14)III/34 LSA CODE A IV/4.4.7.2 30ABC
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 8 July 2016
Resolved
ALL AUDIBLE & VISUAL HIGH LEVEL ALARMS ON DECK WERE INOPERABLE. MULTIPLE HIGH LEVEL & OVERFILL ALARMS BOTH AUDIBLY AND VISUALLY, INOPERABLE IN THE CARGO CONTROL ROOM. 46CFR39.2007( C)(3)
74SOLAS(14)VII/10.1
IBC CODE 15.19.6 IBC CODE 15.19.7.2 30ABC
Accommodation/Occupational Safety › Ventilation › General
Issued 8 July 2016
Resolved
ATMOSPHERIC CONDITIONS INSIDE STEERING GEAR ROOM FOUND TO BE OF LOW OXYGEN CONTENT. VENTILATION FAN ON FANTAIL FOUND TO BE INOPERABLE. 74SOLAS(04CONS)II-1/35 30ABC
Fire Fighting › Fixed Deck Foam System › Valves
Issued 8 July 2016
Resolved
FOAM LINE ISOLATION VALVE SEIZED. 74SOLAS(01CONS)II-2/61.9 30ABC
Engineering › Compressed Air System (control) › Valve
Issued 8 July 2016
Resolved
THE DATA PLATE ON THE AIR PRESSURE SYSTEM RELIEF VALVE WAS ILLEGIBLE. 74SOLAS(04CONS)II-1/34.1 17AC
Fire Fighting › Self-contained Breathing Apparatus › Air Supply (minutes)
Issued 8 July 2016
Resolved
DISPLAYED CERTIFICATE FOR AIR COMPRESSOR USED FOR REFILLING SCBA BOTTLES EXPIRED IN 2015. 74SOLAS(14)VII/10.1
IBC CODE 14.2.6 17AC
Engineering › Freshwater System (air cooling) › Piping
Issued 8 July 2016
Resolved
FRESHWATER GENERATOR, AIR CONDITIONING SUPPLY MAIN, TOILET SUPPLY PIPE LEAKING DUE TO CORROSION ON PIPE, SOFT PATCH INSTALLED. 74SOLAS(04CONS)II-1/26.1 17AC
Communications › Internal Communications System › Sound-powered Telephone
Issued 8 July 2016
Resolved
EMERGENCY COMMUNICATIONS FROM REMOTE ENGINE CONTROL STATION NON-EXISTENT. 74SOLAS(04CONS)II-1/37.1
74SOLAS(04CONS)37.2 17AC
Electrical › Electrical Distribution System (service) › Switchboard
Issued 8 July 2016
Resolved
FRAMO POWER PACK ELECTRICAL PANEL HAS BROKEN NON-CONDUCTIVE GRAB RAIL. 74SOLAS(04CONS)II-1/45.1.3 17AC
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 8 July 2016
Resolved
BONDING STRAPS MISSING OR INADEQUATE. 74SOLAS(14)VII/10.1
IBC CODE 10.2 17AC
Engineering › Pressure Vessel › Piping
Issued 8 July 2016
Resolved
FRAMO PUMP HYDRAULIC LINE ISOLATION VALVE SEIZED AND INOPERABLE. 74SOLAS(04CONS)II-1/26.1 17AC
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 8 July 2016
Resolved
TANK 7 STARBOARD TEMPERATURE SENSOR IS INOPERABLE. 74SOLAS(14)VII/10.1
IBC CODE 7.1.5 17AC
Deck/Cargo › Holds/Tanks › Tank Pressure Monitoring Device
Issued 8 July 2016
Resolved
TANK 7 STARBOARD PRESSURE MONITORING SYSTEM INOPERABLE. 74SOLAS(14)VII/10.1
IBC CODE 8.3.3 17AC
Deck/Cargo › Holds/Tanks › Ullage
Issued 8 July 2016
Resolved
TANK 7 STARBOARD UNABLE TO MEASURE ULLAGE. 74SOLAS(14)VII/10.1
IBC CODE 13.1.1 17AC
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 8 July 2016
Resolved
GLAND SEAL LEAKAGE AND MOTOR WIRING NOT INSTALLED PROPERLY ON EMERGENCY FIRE PUMP. 74SOLAS(01CONS) II-2/21 17AC
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 8 July 2016
Resolved
FIRE CONTROL PLAN DOES NOT LIST SELF CLOSING DOORS. 74SOLAS(01CONS) II-2/20.1 17AC
Construction/Loadline › Markings › Load Line Mark
Issued 8 July 2016
Resolved
THE LOAD LINE WAS NOT PAINTED IN CONTRASTING COLORS. 66 ICLL I/8 40AC
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 8 July 2016
Resolved
FOUND VESSEL TO BE SUBSTANDARD AND NONCONFORMING WITH THE APPLICABLE CONVENTIONS REGULATING THE VESSEL. 74SOLAS(14)IX/3.1 ISM PART A10.1
Documentation › Certificates/Documents › Certificate of Compliance (Fish)
Issued 23 January 2009
Resolved
VESSEL CONDUCTED CARGO OPERATIONS WITH AN INVALID COC. VESSEL DID NOT HAVE ANN EXAM DUE 27 DEC 2008.
Navigation › Emergency Steering › Compass Reading for Emergency Steering
Issued 23 January 2009
Resolved
VESSEL RUDDER INDICATOR COULD NOT BE READ FROM THE BRIDGE OR IN THE STEERING ROOM. VESSEL IS TO MAKE PROPER REPAIRS TO THE SATISFACTION OF CLASS AND PROVIDE ATTESTATION TO LOCAL OCMI.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 27 December 2007
Resolved
Noted 5' X 25' X 3/8" plate steel lying on its side attached to the walkway railing aft of the midship crane. Plate is presently secured with poor condition line. Properly store plate.
Navigation › Piloting/Steering › Maneuvering Information Fact Sheet
Issued 24 December 2007
Resolved
Provide updated maneuvering fact sheet IAW 33 CFR 164.35 (G) (5) to include bow thrusters.
Deck/Cargo › Mooring/Anchoring › Mooring Line/Hawser
Issued 24 December 2007
Resolved
Noted AFT STBD mooring line heavily frayed. Renew the line.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.