CARIBBEAN PRINCESS

CARIBBEAN PRINCESS is a 2004 passenger vessel (inspected). The Coast Guard has recorded 120 inspections since 2004, most recently in June 2026, along with 52 deficiencies and 12 operational controls.

Records from 2004 to 2026. Most recent: inspection, 18 June 2026.

Built
2004
Last inspected
18 June 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9215490 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
670768
Flag
BERMUDA
—
Maury page id
psix-670768

Inspections, by type

…with no type recorded57
Years with a record 22 calendar years (2004–2026)
The 120 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it112894 - Convention (Subpart B), Gross Ton
53296 - Displacement, Metric Ton
85676 - Convention (Subpart B), Net Ton
10046 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

DOUBLOON Passenger (Inspected) · MISLE 289346 · 24 January 2006 · activity 2577263

Inspection history · 120

18 June 2026 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8407578
7 June 2026 In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8393729
13 March 2026 COC-CVE Annual · PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8324093
28 October 2025 MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8259742
15 September 2025 PSC B · COC-CVE Quarterly
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8235013
28 March 2025 COC-CVE Annual · PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8101169
26 November 2024 COC-CVE Quarterly · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8035633
3 April 2024 PSC A · COC-CVE Annual
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7887890
25 October 2023 COC-CVE Annual · PSC A
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7814021
15 September 2023 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7794518
16 June 2023 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7716672
23 May 2023 COC-CVE Quarterly
Type not classified · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7693749
3 November 2022 COC-CVE Annual · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7584771
11 October 2022 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7579898
22 September 2022 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7564884
1 September 2022 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7548928
13 August 2022 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7532214
13 August 2022 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7541342
17 May 2022 COC-CVE Quarterly
Type not classified · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7451747
16 April 2022 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7432238
19 November 2021 PSC A · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7352201
5 April 2020 In-Service Inspection
Physical examination · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 6935495
1 April 2020 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6933927
8 March 2020 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6922476
1 November 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6858283
29 October 2019 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6856601
16 October 2019 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6837366
14 October 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6834667
27 September 2019 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6822355
25 September 2019 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6822083
22 September 2019 COC-CVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6817043
16 August 2019 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6785887
1 June 2019 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6700168
21 May 2019 In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6689466
20 May 2019 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6688748
6 April 2019 COC-CVE Quarterly · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6656343
8 October 2018 Ballast Water Examination · COC-CVE Annual · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6554824
18 September 2018 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6554096
9 May 2018 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6410215
11 April 2018 Ballast Water Examination · COC-CVE Quarterly · ISPS III Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6387798
1 April 2018 MARPOL Annex I Examination · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6382684
8 March 2018 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6370880
7 October 2017 Ballast Water Examination · COC-CVE Annual · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6280337
6 April 2017 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6118787
8 March 2017 COC-CVE Quarterly
Type not classified · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6101123
11 February 2017 Deficiency Check · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6087487
11 December 2016 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6055787
23 September 2016 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6010705
19 September 2016 Ballast Water Examination · COC-CVE Annual · ISPS I Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6004094
20 March 2016 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5914201
7 February 2016 COC-CVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5811940
29 October 2015 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5753480
26 October 2015 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5757341
14 October 2015 Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5742224
7 October 2015 Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5737506
21 September 2015 COC-CVE Quarterly · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5725372
5 August 2014 Ballast Water Examination · COC-CVE Quarterly · MARPOL Annex I Examination · ISPS III Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4941119
22 June 2014 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4901313
20 June 2014 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4894308
18 June 2014 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4898346
14 June 2014 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4891244
1 March 2014 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4808289
26 February 2012 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4251173
25 February 2012 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4253639
20 February 2012 Ballast Water Examination · ISPS II Exam · COC-CVE Annual · PII Safety Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4247636
29 January 2012 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4280613
26 December 2011 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4214854
25 August 2011 COC-CVE Quarterly · ISPS III Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4123540
12 February 2011 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3946703
3 December 2010 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3903276
12 November 2010 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3890051
15 October 2010 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3871382
29 March 2010 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3719471
6 March 2010 ISPS II Exam · Ballast Water Examination · COC-CVE Annual · PII Safety Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3690505
28 February 2010 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3737500
23 January 2010 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3670011
25 April 2009 COE-Dockside
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3460313
18 March 2009 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3435836
7 March 2009 MARPOL Annex I Examination · ISPS II Exam · COC-CVE Annual · MARPOL Annex V Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3393762
8 February 2009 In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3414033
20 October 2008 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3348117
15 October 2008 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3348212
5 October 2008 NPV Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3338819
5 October 2008 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3339405
30 August 2008 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3312476
30 August 2008 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3321542
20 August 2008 COC-CVE Quarterly · ISPS II Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3303707
27 May 2008 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3228823
8 May 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3204359
6 March 2008 COC-CVE Annual · MARPOL Annex V Examination · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3159325
30 December 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3124558
9 December 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3114125
20 October 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3084375
27 September 2007 ISPS II Exam · COC-CVE Quarterly
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3067555
13 May 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2936958
15 March 2007 COC-CVE Annual · ISPS II Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2888666
27 January 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2862504
12 January 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2854768
1 October 2006 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2792742
19 September 2006 COC-CVE Quarterly
Type not classified · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2781759
16 June 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2681824
28 March 2006 ISPS II Exam · COC-CVE Annual
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2584088
24 January 2006 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2577263
10 December 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2559675
19 November 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2561109
25 October 2005 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2526900
7 October 2005 COC-CVE Quarterly
Type not classified · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2509808
31 May 2005 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2391452
22 May 2005 Random ISPS/MTSA/PSC
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2364532
21 May 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2374496
12 April 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2339422
29 March 2005 Random ISPS/MTSA/PSC · MARPOL Annex II Examination · MARPOL Annex V Examination · COC-CVE Annual
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2316368
15 March 2005 Random ISPS/MTSA/PSC
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2310289
30 November 2004 Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2250439
23 November 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2249426
15 November 2004 Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2241016
5 October 2004 COC-CVE Quarterly
Type not classified · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2213721
5 June 2004 MTSA/ISPS Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2088632
2 April 2004 Certificate of Compliance
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2043127
12 March 2004 Control Verification
Physical examination · Activities Europe · Activity 2038924

Deficiency record · 52

04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 13 March 2026 Resolved
EVERY CREW MEMBER WITH ASSIGNED EMERGENCY DUTIES SHALL BE FAMILIAR WITH THESE DUTIES BEFORE THE VOAGE BEGINS. MULTIPLE LIFE BOAT CREWS WERE UNFAMILIAR WITH THE LOCATION OF THEIR FOOD RATIONS & ENGINE FIRE EMERGENCY PRODEDURES. 74 SOLAS 01 II-2/12.1.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 March 2026
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 13 March 2026 Resolved
TWO MEANS OF ESCAPE SHALL BE PROVIDED FROM EACH MACHINERY SPACE. PSCO OBSERVED INOPERABLE ESCAPE DOOR FROM THE ENGINE ROOM TO I95. 74 SOLAS 01 II-2/28.3.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 March 2026
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 March 2026 Resolved
EACH SECTION OF SPRINKLERS SHALL BE CAPABLE OF BEING ISOLATED BY ONE STOP VALVE ONLY. THE STOP VALVE IN EACH SECTION SHALL BE READILY ACCESSIBLE AND ITS LOCATION SHALL BE CLEARLY AND PERMANENTLY INDICATED. PSCO OBSERVED VESSEL'S FIRE DOOR 15.3.01 LOCKED AND UNABLE TO BE OPENED BY CREW, WHICH BLOCKED ACCESS TO SECTION VALVES S86 & S87. 74 SOLAS (01) II-2/12.2.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 March 2026
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 13 March 2026 Resolved
DOORS AND DOOR FRAMES IN "B" CLASS DIVISIONS AND MEANS OF SECURING THEM SHALL PROVIDE A METHOD OF CLOSURE WHICH SHALL HAVE RESISTANCE TO FIRE EQUIVALENT TO THAT OF THE DIVISIONS. PSCO OBSERVED UNSAT DOOR LATCH ON DECK 7 MVZ 6 STBD SIDE, NOT ALLOWING THE DOOR TO MEET A "B" CLASS DIVISION.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2026
Resolved 23 March 2026
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 13 March 2026 Resolved
ANY REQUIRED AUTOMATIC SPRINKLER SHALL BE CAPABLE OF IMMEDIATE OPERATION AT ALL TIMES AND NO ACTION BY THE CREW SHALL BE NECESSARY TO SET IT IN OPERATION. PSCO OBSERVED IRREGULARITY IN AMPULE IN PANTRY DECK 10 MVZ 5.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2026
Resolved 23 March 2026
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 13 March 2026 Resolved
Doors and door frames in B class divisions and means of securing them shall provide a method of closure which have the resistance to fire equivalent to that of the division. PSCO observed a self-closing B-15 door not closing, and remaining open in Deck 5, art gallery. 74SOLAS(01)II-2/31.1.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2026
Resolved 23 March 2026
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 13 March 2026 Resolved
THE DAMPER SHALL BE PROVIDED WITH AN INDICATOR WHICH SHOWS WHETHER THE DAMPER IS OPEN OR CLOSED. PSCO OBSERVED NUMEROUS FIRE DAMPER INDICATOR LIGHTs WERE INOPERABLE AS FOLLOWS: #FS/ES06101/1; #CO/SS06101/1; #FS/ES06101/1; #CO/EG.08.3.01; #CO/EG.08.3.01/3; #CO/EG.08.3.01/5; #FD/EG16610/02; #FS/VE01603/1; #FS/VSO2101/1; #FS/VE02101/1; #FD/RP08302/1; #FD/AP08302/1. 74 SOLAS (01) II-2/16.2.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2026
Resolved 23 March 2026
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 13 March 2026 Resolved
ALL FIRE DOORS IN STAIRWAY ENCLOSURED, MAIN VERTICAL ZONE BULKHEADS AND GALLEY BOUNDARIES WHICH ARE NORMALLY KEPT OPEN SHALL BE CAPABLE OF RELEASE FROM A CENTRAL CONTROL STATION AND FROM A POSITION AT THE DOOR. PSCO OBSERVED FIRE SCREEN DOOR IN THE GALLEY DECK 6 INOPERABLE; AND SELF-CLOSING FIRE DOOR # FSD 4.7.15 AFT AT I-95 NOT CLOSING.
Action required: 10 - Deficiency Rectified
Resolved 13 March 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 13 March 2026 Resolved
A FOOD RATION TOTALING NOT LESS THAN 10,000 KJ FOR EACH PERSON THE LIFEBOAT IS PERMITTED TO ACCOMMODATE; THESE RATIONS SHALL BE KEPT IN AIRTIGHT PACKAGING AND STOWED IN A WATERTIGHT CONTAINER. PSCO OBSERVED LIFEBOAT RATIONS IN LIFEBOATS 5, 7, 10, 12, 22, AND 25 THAT LOST AIRTIGHT INTEGRITY. SOLAS(20) III/34 LSA CODE 4.4.8.12
Action required: 10 - Deficiency Rectified
Resolved 13 March 2026
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 16 September 2025 Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. PSCO observed second in command on lifeboat #24 unable to start the lifeboat. 74 SOLAS III/19.2.1
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 16 September 2025
Resolution: Training received on the spot. Deficiency rectified.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 28 March 2025 Resolved
Above the bulkhead deck there shall be at least two means of escape from each main vertical zone or similarly restricted space or group of spaces at least one of which shall give access to a stairway forming a vertical escape. PSCO found the sauna escape access door blocked and inoperable. 74SOLAS01/II-2/28.1.2.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2025
Resolved 29 March 2025
Resolution: Rectified with report to the CG
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 28 March 2025 Resolved
It shall be possible for each door to be opened and closed from each side of the bulkhead by one person only. PSCO found fire doors FSD 10.4.05 not latching and secondary door not activating, FSD 1 4.05 not latching and remaining in open position, and FSD6.2.02 at the theater closing too quick. 74SOLAS01/II-2/30.3
Action required: 10 - Deficiency Rectified
Resolved 28 March 2025
Resolution: Rectified prior finishing the exam.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 28 March 2025 Resolved
The provisions on the prevention of accidents and the protection of health in employment which may be applicable to the work of seafarers, and shall specify measurers for the prevention of accidents which are peculiar to maritime employment. PSCO found a raised ramp located by the rescue boat starboard side posing a tripping hazard. ILO-147/ PWSA 33USC1223(b).
Action required: 10 - Deficiency Rectified
Resolved 28 March 2025
Resolution: Deficiency rectified prior finishing the exam.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 26 November 2024 Resolved
Two means of escape shall be provided from each machinery space. PSCO observed evacuation route fire door (1.5.04) in purifier room was unable to be opened due to pressure and ventilation in the space. 74 SOLAS (01) II-2/28.3.1 Code 50bc
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 December 2024
Resolved 23 December 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 November 2024 Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. PSCO observed water dripping out of light fixture above computer area into containment bucket in the printer room. 74 SOLAS (04 II-1/45.1.3 Code 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 26 November 2024
Resolution: Vessel technicians found potable water pipe leaking from crack in pipe. Technicians applied a soft patch to leak, cleaned leaked water, and replaced light fixture with dry one.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 November 2024 Resolved
Fire hoses shall be of non-perishable material approved by the Administration and shall be sufficient in length to project a jet of water to any of the spaces in which they may be required to be used. Each hose shall be provided with a nozzle and the necessary couplings. In interior locations in passenger ships carrying more than 36 passengers fire hoses shall be connected to the hydrants at all times. PSCO observed fire hose not connected to fire main in the MBR room. 74 SOLAS (01) II-2/4.7.1 Code 10c
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 26 November 2024
Resolution: Fire hose attached to station
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 26 November 2024 Resolved
Doors and door frames in "B" class divisions and means of securing them shall provide a method of closure which shall have resistance to fire equivalent to that of the divisions, ecept that ventilation openings may be permitted in the lower portion of such doors. Where such opening is in or under a door the total net area of any such opening or openings shall not exceed 0.05 m2. When such opening is cut in a door it shall be fitted with a grill made of non-combustible material. PSCO observed B-15 doors 15709, by room c306, aft crew stairway deck 15, and hospital space door 4404 with damaged hinges that would not shut and allow for the passage of flame. 74 SOLAS (01) II-2/31.1.1 Code 10c
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 26 November 2024
Resolution: Doors were repaired.
10 - Safety of Navigation › N/A - No Subsystem › Gyro compass
Issued 26 November 2024 Resolved
All ships of 500 gross tonnage and upwards shall have a gyro-compass heading repeater, or other means, to supply heading information visually at the emergency steering position. STBD side steering room gyro-compass was displaying error code. 74 SOLAS (20) V/19.2.5.2 Code 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 26 November 2024
Resolution: Vessel technician recalibrated repeater.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 26 November 2024 Resolved
The construction of all doors and door frames in "A" class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame, as far as practicable, equivalent to that of the bulkheads in which the doors are situated. PSCOs observed FSD 6.1.03 for room 6123 "Daily paint store" being held open with a hold-back device preventing this door from providing resistance to fire as well as smoke. Door was held open by a coat hanger. 74 SOLAS (01) II-2/30.2 Code 10c
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 26 November 2024
Resolution: Coat hanger removed.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 26 November 2024 Resolved
All life saving appliances and arrangements shall comply with the applicable requirements of the code thje marking required on liferafts shall be SOLAS "A" pack in block capitals od the Roman alphabet. PSCO's observed 04 life rift containers without SOLAS "A" pack markings. 74 SOLAS (20) III/34 LSA Code 4.1.5.2 Code 50bc
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 December 2024
Resolved 19 December 2024
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 3 April 2024 Resolved
Stairways and ladders shall be arranged to provide ready means of escape to the lifeboat and liferaft embarkation deck from all the passenger and crew spaces and from spaces in the which the crew is normally employed, other than machinery spaces. PSCO found multiple crew cabin cooridoors being obstructed by service carts and personal belongings preventing an immediate access to the emergency exits. Also, on deck four, there were several areas with maintenance equipement and boxes of supplies preventing crew from having access to means of escape. 74SOLAS(2001 CONS.)II-2/28.1 10C
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 4 April 2024
Resolution: Staff captain had crew remove items from passageways clearing means of escape to the satisfaction of the US Coast Guard.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 25 October 2023 Resolved
The activation of any detector or manually operated call point shall initiate a visual and audible fire signal at the control panel and indicating units. If the signals have not received attention within 2 min an audible alarm shall be automatically sounded throughout the crew accommodation and service spaces, control stations and machinery spaces of category A. The manually operated call point on deck 7, number 31 105, was tested and received no visual or audible signal at the control panel or at the unit. After failure of the testing unit, crewmember broke the glass on the manually operated call point, still no audible or visual was shown on the control panel or on the unit.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2023
Resolved 25 October 2023
Resolution: Crewmember replaced the manally call point panel and broken glass. PSCO's returned and tested the manual call point and witnessed the audible and visual alarm on both the control panel and on the unit.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 September 2022 Resolved
On voyages of less than 96 hours, an NOA must be submitted before departure, but at least 24 hours prior to entry. Vessel failed to properly submit NOA prior to entry to Sector SENE COTP Zone, from previous port of Baltimore, MD
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 1 September 2022
Resolved 1 September 2022
Resolution: PSCO informed vessel of reporting requirements. Vessel submitted eNOA prior to departure.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 17 May 2022 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs in the protection of openings and penetrations in divisions. Two B15 fire doors leading to the "Bell Box" galley space on Deck 11, Zone 6 were found with rags tied around the door latch and handle preventing the door from securely closing. 74 SOLAS 20 II-2/14.2.1
Action required: 10 - Deficiency Rectified
Due 17 May 2022
Resolved 17 May 2022
Resolution: Rags were removed from the door latch and handle and discussed with crew.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 17 May 2022 Resolved
The purpose of this regulation is to provide means of escape so that persons onboard can safely and swiftly escape to the embarkation deck. The following functional requirements shall be met: safe escape routes shall be provided and additional aids for escape shall be provided to ensure adequate design for emergency situations. On deck 11, zone 6 in the "Bell Box" galley space, the chef's office has no installed PA system and a window which was blocked by papers and signage. This installation does not allow for immediate notification in event of emergency when door is shut. 74 SOLAS 20 II-2/13.1.3
Action required: 10 - Deficiency Rectified
Due 17 May 2022
Resolved 17 May 2022
Resolution: Papers and signage were removed from the window and discussed with crew.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 19 November 2021 Resolved
Indicating units shall, as a minimum, denote the section in which a detector or manually operated call point has operated...One indicating unit shall be located on the navigation bridge. Manual calls points 3.98 and 1.2 indicated local activation, but no indication was received on the bridge. SOLAS 01 II-2/13
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 November 2021
Resolution: Crew electricians were able to identify that the navigation bridge had a fault via the alarm log. Once the fault was corrected, the manual call points were tested again and the navigation bridge received audible notification.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 19 November 2021 Resolved
Occurrence of a fault condition shall initiate a visual and audible fault signal at the control panel. Manual call point and smoke alarms in the incinerator room did not alarm at the indicating unit located on the bridge. Smoke detectors 01.1 and 03.125 were not being received on the bridge as activated. SOLAS 01 II-2/13.1.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 November 2021
Resolution: Crew electricians were able to identify that the navigation bridge had a fault via the alarm log. Once the fault was corrected, the smoke detectors in the incinerator space were tested again and the navigation bridge received audible notification.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 19 November 2021 Resolved
Furniture shall not be permitted in the passenger and crew corridors forming escape routes in cabin areas. PSCO's observed a series of trolleys stowed in a crew cabin corridor, by crew stateroom 4307, chairs and boxes located on the forward crew corridors on deck 4, and extra chairs in the corridor located inside the medical space on deck 4. SOLAS 01 II-2/41-2.4.10
Action required: 10 - Deficiency Rectified
Resolved 19 November 2021
Resolution: Crew removed the the trolleys by crew cabin 4307, in the forward crew corridors on deck, and extra chairs in the medical corridor.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 22 September 2019 Resolved
Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. PSCO observed the #21 lifeboat was not operational when tested during drills due to faulty starter. 17c 74 SOLAS (14) III/20.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 September 2019
Resolved 22 September 2019
Resolution: 10c -Starter was replaced and engine on #21 lifeboat started prior to conclusion of exam.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 22 September 2019 Resolved
The appropriate time of closure for hinged fire doors shall be no more than 40s and no less than 10s from the beginning of their movement with the ship in the upright position. PSCO observed FSD 11.4.12 closed too slow, FSDs 7.4.09 and 7.3.09 closed too fast, and FSDs 16.7.05 and 14.7.08 did not close. 50ac 74 SOLAS (01) II-2/30.4.2
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2019
Resolved 26 September 2019
Resolution: Vessel provided documentation from class attesting that repairs have been made to the fire doors 11.4.12,7.4.09, 7.3.09, 16.7.05, and 14.7.08
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 June 2019 Resolved
Main and auxiliary machinery essential for the propulsion, control and safety of the ship shall be provided with effective means for its operation and control. Port propulsion motor suffered a failure of the aft regulator control card. 74 SOLAS(04 CONS) CH.II-1/REG 31.1
Action required: 10 - Deficiency Rectified
Resolved 1 June 2019
Accommodation/Occupational Safety › Heating › Radiator
Issued 11 April 2018 Resolved
9900-Electric Radiators shall be fitted with an element so exposed that clothing, curtains or other similiar materials can not be scorched or set on fire by heat from the element. Heating element id in a fixed position causin scorching on the bulkhead in the Sauna. Solas (01) II-2/18.3 - 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2018
Resolved 9 May 2018
Resolution: LR - Mens sauna starboard dk 16 electric radiator now relocated away from bulkhead/wooden panelling and permanently affixed to deck by means of mechanical fastening.
Fire Fighting › Structural - A Class Divisions › Service Spaces
Issued 11 April 2018 Resolved
0750- A class divisions are those divisions formed by bulkheads and decks which comply with the following: They shall be insulated with approved Non-combustable material. PSCO observed torn/missing insulation in fan room port and stbd side on deck 16. SOLAS (01) II-2/13.3 - 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2018
Resolved 9 May 2018
Resolution: LR - Deck 16 port and starboard fan rooms numbers 16601 and 16602 now examined. Insulation material in way of fan room doors has been repaired by ships crew with non-combustible insulation material.
Fire Fighting › Means of Escape › Blocked
Issued 11 April 2018 Resolved
Below the bulkhead deck two means of escape at least one of which shall be independent of watertight doors. PSCO observed closed gate device in pressig room preventing means of escape. SOLAS (01) II-2/28.1.1 - 16AC
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2018
Resolved 9 May 2018
Resolution: LR - Pressing room dk 2 midships examined and found with gate device permanently removed in way of starboard side.
Engineering › Electric Propulsion System › Winding
Issued 6 April 2017 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Port propulsion electrical aft motor coils 171, 172, and 173 were found damaged by the end winding area indicating insulation breakdown. 74Solas Ch1/Reg11(a)
Action required: 705 - Other - as specified
Due 31 October 2019
Resolved 1 June 2019
Resolution: Class Attestation received stating Windings on Port Aft Pod tested and found satisfactory along with control card replacement. No limitations.
Personnel › Training › Proficiency in Survival Craft
Issued 11 March 2017 Resolved
0925: The person in charge of the survival craft shall see that the crew under his command are acquainted with their duties. At least 5 lifeboats were observed during abandon ship drill with either the person in charge or second-in-command not knowing how to start the lifeboat. 74SOLAS(14)III/10.5 17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 March 2017
Personnel › Training › Passenger Safety
Issued 11 March 2017 Resolved
0299: Seafarers shall receive safety fam & basic training IAW A-VI/1 of STCW. Designated stairway guides do not have the basic training completed as required by STCW(11)VI/1.2. Full def located in narrative. STCW(11)VI/1.1 40bc
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 March 2017
Resolution: Flag/Company provided info to satisfy def.
Engineering › Engine Controls (Electric/Electronic) › Software
Issued 11 February 2017 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to wnsure that the ship in all respects will remain fit top proceed to sea without danger to the ship or the persons on board. The aft motor on starboard side engine was reported as not operational. 17ac
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 11 February 2017
Resolved 11 February 2017
Resolution: It was verified, and attested to in class report, by LR that the motor stopped due to a software issue, not a mechanical issue. System is completely operational. Class report received, and copy of alarms from the ECR system were obtained (see documents).
Engineering › Generator (propulsion-electric) › Circuit Board
Issued 11 December 2016 Resolved
Main and Auxiliary machinery essential for the propulsion and safety of the ship shall be provided with effective means for its operation and control. Forward starboard propulsion motor not operational due to defective control panel. 74SOLAS(04)II-1/31.1 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 December 2016
Resolution: Class report received/accepted, def cleared.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 21 September 2015 Resolved
Fire doors in Main Vertical Zones shall be self closing. Multiple fire screen doors did not close properly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 September 2015
Resolved 22 September 2015
Resolution: Vessel corrected all identified fire screen doors prior to the completion of the exam.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 5 August 2014 Resolved
Machinery space of category A shall be adequately ventilated so that an adequate supply of air is maintained to the space for the operation of the machinery. In both the port and starboard emergency generator spaces the bulkhead mounted ventilation louvers did not open properly in order to maintain proper ventilation to the space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 August 2014
Resolved 14 October 2015
Resolution: The ship''s crew serviced the louvers so that they opened and closed properly in order to properly ventilate the space.
Fire Fighting › Structural Fire Protection - General › Superstructure Construction
Issued 20 February 2012 Resolved
Structural fire proctection missing above access doors to battery room, emergency generator room, and fan room. SOLAS Reg II-2 9 1.3
Action required: 705 - Other - as specified
Due 20 March 2012
Resolved 6 March 2012
Resolution: Fire protectection added.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 20 February 2012 Resolved
Structural fire proctection between WFT room and ventilation room deck 6 missing. SOLAS II-2 9.3
Action required: 705 - Other - as specified
Due 20 March 2012
Resolved 6 March 2012
Resolution: Fire procetection added.
Fire Fighting › Ventilation Systems › Operating Controls
Issued 20 February 2012 Resolved
Fire damper close indicators not operational deck 8, deck 5/7 main stairs, and deck 4 embarkation.
Action required: 705 - Other - as specified
Due 20 March 2012
Resolved 6 March 2012
Resolution: Fire damper indicators operational.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 20 February 2012 Resolved
Fire Screen Door 11-6-02 not labeled and closed immediately.
Action required: 705 - Other - as specified
Due 20 March 2012
Resolved 6 March 2012
Resolution: FSD labeled and closing.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 8 February 2009 Resolved
Submit plans for all changes made to the vessel during the Jan 2009 dry-dock to the Marine Safety Center for review.
Condition: Unknown
Due 15 February 2009
Resolved 26 May 2009
Resolution: Company provided documentation that plans were submitted.
Fire Fighting › Structural - B Class Divisions › Doors
Issued 7 October 2005 Resolved
Provide classification society acceptance of B15 joiner door (missing) in way of Cambusa. Deck 4, Zone 7.
Due 4 November 2005
Resolved 21 October 2005
Resolution: Def corrected
Deck/Cargo › Cargo Stowage › General
Issued 5 October 2004 Resolved
Provide class acceptance of storage areas located in stairwells to disco in vicinity of decks 16 & 17.
Due 5 December 2004
Resolved 30 November 2004
Deck/Cargo › Cargo Stowage › General
Issued 5 October 2004 Resolved
Provide class acceptance of storage in stairwell portside deck 14.
Due 5 December 2004
Resolved 30 November 2004
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 5 October 2004 Resolved
Provide arrows to indicate direction of opening for all fire screen doors.
Due 5 December 2004
Resolved 30 November 2004
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 5 October 2004 Resolved
Fire screen door 6.7.07 to remain closed until deck is repaired to assure proper automatic closure.
Due 13 October 2004
Resolved 19 October 2004
Resolution: Verified proper door closure.
Construction/Loadline
Issued 12 March 2004 Resolved
Properly stow all lifeboat/tender boat equipement and perform fire and lifeboat drills using the port lifeboats at the vessel's first U.S. port of call.
Action required: 705 - Other - as specified
Due 30 March 2004
Resolved 30 March 2004

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.