MAURY USCG vessel records
← All vessels

BITU EXPRESS

BITU EXPRESS is a 2002 tank ship. The Coast Guard has recorded 10 inspections since 2017, most recently in April 2024, along with 8 deficiencies.

Records from 2017 to 2024. Most recent: inspection, 4 April 2024.

Built
2002
Last inspected
4 April 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 4 April 2024
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2017–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9265689
670809
Flag
PANAMA
Maury page id
psix-670809

Documentation record

Tonnage as PSIX records it28323 - Convention (Subpart B), Gross Ton
11602 - Convention (Subpart B), Net Ton
59157 - Displacement, Metric Ton
49282 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

10 inspections, each with its date, unit and type; 8 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 10

4 April 2024 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7888776
25 March 2024 PSC B · COC-TVE Renew
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7883652
12 August 2022 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7531444
12 July 2022 COC-TVE Renew · PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7504406
5 March 2021 PSC B · Ballast Water Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7150754
27 August 2020 COC-TVE Renew · PSC A · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7043334
15 July 2019 ISPS II Exam · COC-CHEM & TVE Annual · PII Safety Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6744333
8 July 2019 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6750396
26 July 2018 Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6485318
19 February 2017 COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6089816

Deficiency record · 8

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 March 2024 Resolved
THERE SHALL BE AT LEAST ONE PORTABLE FOAM APPLICATOR UNIT COMPLYING WITH THE PROVISIONS OF THE FSS CODE. PSCO FOUND HOSE ON EDUCTOR DRY ROTTED AND TORN. CHIEF ENGINEER REPLACED ON THE SPOT.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 25 March 2024
Resolved 25 March 2024
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 March 2024 Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF PRESENT REGULATIONS TO ENSURE SHIP IN ALL RESPECTS PROCEED TO SEA WITHOUT DANGER TO SHIP OR PERSONS ON BOARD. PSCO OBSERVED EMERGENCY LIGHT ABOVE FORWARD LIFERAFT BROKEN OFF OF DEDICATED BRACKET AND BEING HELD ON WITH NYLON ROPE
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2024
Resolved 4 April 2024
Resolution: bracket cropped and renewed and light fixtures was replaced and tested.
02 - Structural Conditions › N/A - No Subsystem › Cargo tank vent system
Issued 25 March 2024 Resolved
FLAME SCREENS SHALL BE SINGLE SCREEN OF CORROSION-RESISTANT WIRE OF AT LEAST 30 BY 30 MESH OR TWO FITTED SCREENS OF AT LEAST 20 BY 20 WIRE MESH. SPACED NOT LESS THAN 1/2 INCH OR MORE THAN 1 AND 1/2 APART. PSCO OBSERVED HOLES IN FLAME SCREENS ON #2 STBD AND #3 PORT PV VALVES. PUMPMAN WAS ABLE TO REPLACE DURING INSPECTION.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 25 March 2024
Resolved 25 March 2024
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 27 August 2020 Resolved
07126 - Arrangements for distribution and utilization of the oil fuel shall be such as to ensure safety of the ship and persons onboard. MDE fuel injector on No. 6 cylinder head was found leaking. MDE pumps No. 2, 4, and 6 were also found leaking. 74SOLAS(01)II-2/15.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 August 2020
Resolution: Received Class report attesting to the proper repairs.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 August 2020 Resolved
07119 - The condition of the ship and it's equipment shall be maintained to conform w/ the provisions of present regulations to ensure the ship remains fit to proceed at sea without danger to ship or persons onboard. PSCO observed saturated lagging on No. 1 cargo pump pipe and oil accumulation on the deck where the pipe penetrates the deck above cargo pumps. 74SOLAS(14)I/11 33CFR156.120(p)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 August 2020
Resolution: Received class report stating that the No. 1 cargo line was isolated and placed out of service.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 27 August 2020 Resolved
07199 - The condition of the ship and it's equipment shall be maintained to conform w/ the provisions of present regulations to ensure danger to ship or persons onboard. PSCO observed loose wires to sensors for high temp on No. 1 cargo pump. Crew could not initially demonstrate test of No. 1 bearing high temp sensor and No. 1 casing over high sensor. Before the exam ended, ship's crew was able to demonstrate test of all alarms with satisfactory results. 74SOLAS(14)1/11
Action required: 10 - Deficiency Rectified
Resolved 27 August 2020
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 26 July 2018 Resolved
01117-IOPP-An International Oil Pollution Prevention Certificate shall be issued to any oil tanker of 10 gross tonnage and above and any other ships of 40 gross tonnage and above. PSCO identified that IOPP Supplement Form B records the incorrect quantity (25cm3) for the maximum throughput of OWS and does not provide of slop tanks on board. RO to provide corrected IOPP supplement to vessel. MARPOL Annex I/7 50 a
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 August 2018
Resolved 2 August 2018
Resolution: Vessel submitted corrected IOPP Certificate and Supplement identifying number of slop tanks and proper throughput for OWS.
Construction/Loadline › Hull › Side Shell
Issued 19 February 2017 Resolved
The vessel has a pinhole leak in the side shell, starboard side below the life boat in way of a fuel tank. Make temporary repairs to the satisfaction of the Class society and U.S Coast Guard, prior to departure from port.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 19 February 2017
Resolved 20 February 2017
Resolution: Cleared while onboard and with Class Report.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.