MAURY USCG vessel records
← All vessels

MAUNAWILI

Built
2004
Last inspected
23 May 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 23 May 2026
…with no type recorded17
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9268538
671400
Flag
UNITED STATES
Maury page id
psix-671400

Documentation record

Registered dimensions (L × B × D)661.5 ft × 105.6 ft × 63.6 ft
Registered tonnagegross 32,575 / net 14,558
ITC dimensions (L × B × D)661.5 ft × 105.6 ft × 63.6 ft
ITC tonnagegross 32,575 / net 14,558
BuilderKVAERNER PHILADELPHIA SHIPYARD INC · PHILADELPHIA, PA, UNITED STATES · built 2004
Hull materialSteel
PropulsionDiesel Direct
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portHONOLULU, HI
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 3 August 2026 · expires 31 August 2027
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it32575 - Convention (Subpart B), Gross Ton
14558 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 151 inspections, each with its date, unit and type; 49 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 151

23 May 2026 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8382825
15 May 2026 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8373519
28 April 2026 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8357519
30 March 2026 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8334402
16 March 2026 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8327058
6 March 2026 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8327594
4 March 2026 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8320146
28 February 2026 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8317743
23 February 2026 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8314448
22 February 2026 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8314733
20 February 2026 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8313078
2 February 2026 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8305064
23 January 2026 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8300669
20 January 2026 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8299030
5 January 2026 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8290327
22 December 2025 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8290302
24 November 2025 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8273550
24 October 2025 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8258981
14 October 2025 Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8251993
11 October 2025 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8250548
30 September 2025 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8244425
19 September 2025 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8234840
8 September 2025 Explosive Handling Operation-Administrative
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8229972
24 August 2025 Explosive Handling Operation-Administrative
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8219525
22 August 2025 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8215511
18 August 2025 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8231042
16 August 2025 Explosive Handling Operation-Administrative
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8208723
8 August 2025 ACP COI Oversight · Annual Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8186899
2 August 2025 Explosive Handling Operation-Administrative
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8202181
22 July 2025 Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8192122
7 June 2025 Explosive Handling Operation-Administrative
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8150581
2 June 2025 Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8150356
24 May 2025 Explosive Handling Operation-Administrative
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8142459
12 May 2025 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8133409
10 May 2025 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8132217
29 April 2025 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8123185
25 April 2025 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8117255
18 April 2025 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8114019
18 April 2025 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8114136
14 April 2025 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8111646
12 April 2025 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8108527
31 March 2025 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8102931
29 March 2025 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8101777
18 March 2025 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8095837
15 March 2025 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8106764
3 March 2025 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8087581
22 February 2025 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8084074
11 February 2025 Explosive Handling Operation-Administrative
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8078301
3 February 2025 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8073924
1 February 2025 Explosive Handling Operation-Administrative
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8072578
18 October 2024 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8087700
7 October 2024 Administrative Inspection · Annual Inspection · ACP Annual Oversight
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7956773
12 July 2024 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7957082
29 May 2024 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7923146
7 May 2024 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 8041709
2 May 2024 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7905090
16 February 2024 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7866423
5 February 2024 Administrative Inspection · ACP Drydock Oversight
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7860399
23 January 2024 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7853545
19 January 2024 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7850599
15 January 2024 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7848530
10 January 2024 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7847911
11 December 2023 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7837604
27 November 2023 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7830113
14 November 2023 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7824639
2 November 2023 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7819193
28 October 2023 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7819036
23 October 2023 Periodic Inspection · Deficiency Check · ACP Annual Oversight
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7813907
16 October 2023 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7809325
14 October 2023 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7815541
6 October 2023 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7802049
30 September 2023 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7801108
25 September 2023 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7798337
25 September 2023 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7799563
21 September 2023 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7795963
5 August 2023 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7760823
28 July 2023 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7752171
22 July 2023 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7752037
11 July 2023 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7739763
8 July 2023 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7736842
26 June 2023 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7725040
12 May 2023 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7690183
18 April 2023 Explosive Handling Operation-Commercial
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7679961
7 March 2023 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7647302
6 September 2022 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7516062
8 July 2022 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7504182
14 June 2022 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7477347
24 May 2022 Underwater Inspection in lieu of Drydock
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7458612
21 February 2022 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7399631
5 October 2021 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7327385
20 September 2021 ACP Annual Oversight · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7316370
26 July 2021 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7294860
15 February 2021 Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7142047
20 January 2021 Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7127814
28 November 2020 Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7100871
19 November 2020 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7101055
15 November 2020 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7097618
31 October 2020 Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7084672
18 October 2020 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7079109
12 October 2020 Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7075769
28 September 2020 Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7067308
14 September 2020 Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7060070
31 August 2020 Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7047176
19 August 2020 Administrative Inspection · COI Inspection · Re-Inspection · ACP COI Oversight · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7037671
17 August 2020 Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7035730
7 August 2020 Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7024022
27 July 2020 Deficiency Check · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7018617
6 July 2020 Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6998911
6 July 2020 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7001227
5 July 2020 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7001245
28 June 2020 Administrative Inspection · Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6990626
26 June 2020 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6987941
26 May 2020 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6960837
4 May 2020 ACP Annual Oversight · Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6952534
16 December 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6876839
27 November 2019 Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6864059
23 November 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6862455
18 November 2019 Deficiency Check · ACP Additional Oversight – Risk Assessment · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6855216
15 November 2019 Deficiency Check · In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6856661
12 November 2019 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6854133
1 November 2019 Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6847072
17 October 2019 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6836913
15 October 2019 Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6834712
15 October 2019 Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6835185
30 September 2019 Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6824731
17 September 2019 Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6813932
3 September 2019 Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6803001
4 August 2019 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6773625
16 July 2019 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6751578
18 June 2019 ACP Drydock Oversight · Drydock Exam
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6684478
26 March 2019 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6618380
26 December 2018 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6602621
17 December 2018 Examination of Repairs · Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6599320
11 December 2018 Administrative Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6597831
5 December 2018 Deficiency Check · Administrative Inspection · Damage Survey
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6592694
3 December 2018 Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6593718
6 November 2018 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6577545
30 August 2018 ACP Annual Oversight · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6507292
20 June 2018 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6450319
27 December 2017 Damage Survey · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6329535
27 December 2017 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6347333
12 August 2017 Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6241979
8 August 2017 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6212327
20 June 2017 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6302147
24 April 2017 Underwater Inspection in lieu of Drydock
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6120014
24 April 2017 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6131943
29 August 2016 Administrative Inspection · ACP Annual Oversight
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5986507
9 May 2016 Examination of Repairs · Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5870159
30 April 2016 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5867424
1 March 2016 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5813981
29 January 2016 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 5852974

Deficiency record · 49

07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 7 October 2024 Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures, other than power-operated watertight doors and those which are normally locked, shall be self-closing. The following 04 self-closing A-60 fire screen doors did not properly close and latch: 02 doors in the purifier room, 01 door in the engine casing near the boiler, and 01 door in the engine control room. 74SOLAS (01) II-2/30
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2024
Resolved 9 October 2024
Resolution: Received class report attesting to repair of the doors.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 7 October 2024 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a deign and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. MI identified exhaust leak on SSDG 4. 74 SOLAS (04) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2024
Resolved 9 October 2024
Resolution: Received class survey report attesting to repairs on SSDG 4.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 October 2024 Resolved
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards will be ensured. MI identified portable fan near boiler burner secured overhead via a ratchet strap and a fan installation near SSDG 3 with approximately 30 feet of cable hanging over the genset that was secured to an overhead pipe via a t-shirt.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 7 October 2024
Resolved 7 October 2024
Resolution: Portable electrical installations were removed.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 2 November 2023 Resolved
Fracture discovered between #3 double bottom port and #4 double bottom port ballast tanks. Temporary repairs made; NDT conducted to identify edges of crack and drill stop. Complete permanent repairs and submit ABS report of survey for repairs prior to departure. 46 CFR 91.45
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 6 November 2023
Resolved 3 November 2023
Resolution: Surveyor submitted report of repairs condutcted on fracture. Finding # 1703.0
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 23 October 2023 Resolved
The electrical power available shall be sufficient to supply all those services that are essential for safety in an emergency, due regard being paid to such services as may have to be operated simultaneously. A ground fault was discovered on the 110/220V emergency switchboard. 74 SOLAS (04) II-1/43.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2023
Resolved 27 October 2023
Resolution: Accepted as condition of class via ABS WO 6076905.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 23 October 2023 Resolved
The company should establish procedures, plans and instructions, including checklists as appropriate, for key shipboard operations concerning the safety of the personnel, ship and protection of the environment. The various tasks should be defined and assigned to qualified personnel. Identified 02 circuit breakers on the 110/220V switchboard secured for maintenance and/or inoperable. The circuit breakers were not logged in the Lock Out Tag Out Log nor properly secured with the appropriate tag as outlined in the vessel’s Lockout-Tagout Safety Procedures. 74 SOLAS (20) IX/1.3 ISM Code Part A/7
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 27 October 2023
Resolution: Accepted as condition of class via ABS WO 6076905.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 23 October 2023 Resolved
Means shall be provided to close all opening which may admit air to or allow gas to escape from a protected space. Portable electrical extension cord found routed through natural ventilation damper for Emergency Generator room. Extension cord removed in the presence of the attending Marine Inspector. 74 SOLAS (01) II-2/5.1.4
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 23 October 2023
Resolution: Accepted as condition of class via ABS WO 6076905.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 23 October 2023 Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures, other than power-operated watertight doors and those which are normally locked, shall be self-closing. The self closing device for the following fire screen doors was found to be inoperable: main stairway doors at decks 2, 3, 4, 6, Handling Room, Food Room, Emergency Gear Locker 2 (Incinerator Room), Engine Room Workshop Emergency Escape, Fuel Oil Purifier Room Aft. 74 SOLAS (01) II-2/30
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2023
Resolved 27 October 2023
Resolution: Accepted as condition of class via ABS WO 6076905.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 23 October 2023 Resolved
The construction of all doors and door frames in “A” class divisions shall be provide resistance to fire as well as to the passage of smoke and flame, as far as practicable, equivalent to that of the bulkheads in which the doors are located. Steering Gear Room fire screen door is missing fire-resistant insulating seal. Emergency Gear Locker 2 (Incinerator Room) has 02 holes drilled completely through the door jam where pre-existing self-closing device as mounted. 74 SOLAS (01) II-2/30
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2023
Resolved 27 October 2023
Resolution: Accepted as condition of class via ABS WO 6076905.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 23 October 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Discharge pressure gauge on the No. 2 Fire Pump found inoperable. 74 SOLAS (20) I/11
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2023
Resolved 27 October 2023
Resolution: Accepted as condition of class via ABS WO 6076905.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 23 October 2023 Resolved
Where penetrations of watertight bulkheads and internal decks are necessary for electrical cables, arrangements are to be made to maintain the watertight integrity. Multi cable transit for electrical cables penetrating the deck at the Engine Room entrance found to be constructed of incompatible components. 74 SOLAS (04) II-1/25-9.1
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2023
Resolved 27 October 2023
Resolution: Accepted as condition of class via ABS WO 6076905.
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 23 October 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The yellow flashing strobe light outside of the Fuel Oil Purifier Room found to be inoperable. 74 SOLAS (20) I/11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2023
Resolved 27 October 2023
Resolution: Accepted as condition of class via ABS WO 6076905.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 23 October 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Excessive oil accumulation found under the Main Engine, Diesel Generator 1, Diesel Generator 2, Diesel Generator 3, and Diesel Generator 4. 74 SOLAS (20) I/11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2023
Resolved 27 October 2023
Resolution: Accepted as condition of class via ABS WO 6076905.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 October 2023 Resolved
No electrical equipment shall be installed in any space where flammable mixtures are liable to collect or in compartments such as paint lockers, unless the Administration is satisfied that such equipment: is appropriately certified for safe usage in the dusts, vapours or gases likely to be encountered. Explosion proof light fixture mounted outside of the paint locker found with unauthorized repairs. 74 SOLAS (04) II-1/45.10.4
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2023
Resolved 27 October 2023
Resolution: Accepted as condition of class via ABS WO 6076905.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 October 2023 Resolved
Electrical installations shall be such that all electrical auxiliary services necessary for maintaining the ship in normal operational and habitable conditions will be ensured without recourse to the emergency source of electrical power. Forward mooring winch electrical motor controller found without dripshield. 74 SOLAS (04) II-1/40.1.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2023
Resolved 27 October 2023
Resolution: Accepted as condition of class via ABS WO 6076905.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 23 October 2023 Resolved
The means for securing and maintaining weathertightness shall be to the satisfaction of the administration. The arrangements shall ensure that the tightness can be maintained in any sea conditions. Two cargo hold vent trunks (CL at the aft end of bay 18, and CL at the fwd end of bay 34) were found in poor condition and unable to be secured. ICLL(88)II/16(4)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2023
Resolved 23 October 2023
Resolution: Accepted as condition of class via ABS WO 6076905.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 23 October 2023 Resolved
The means for securing and maintaining weathertightness shall be to the satisfaction of the administration. The arrangements shall ensure that the tightness can be maintained in any sea conditions. Two ventilation trunks on the aft mooring deck found seized in the open position (vent numbers 85 & 114). ICLL(88)II/16(4)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 27 October 2023
Resolution: Vents were lubricated and freed, proper operation demonstrated.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 October 2023 Resolved
Maintenance, testing and inspections of life-saving appliances shall be carried out in a manner having due regard to ensuring reliability of such appliances. Onboard life-jacket found with an expired water light battery. 74SOLAS (20) III/20.3.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 23 October 2023
Resolution: Waterlight replaced in kind.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 6 September 2022 Resolved
Except as provided in paragraph 4.2.2, two means of escape shall be provided from each machinery space of category A. In particular, one of the following provisions shall be complied with: Self-closing fire doors of the same fire integrity standards shall be fitted in the enclosure. The self-closing fire door leading into the steering compartment would not close, preventing the sealing of an A-0 boundary. ABS Finding 1635.0
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2022
Resolved 12 September 2022
Resolution: Self-closing fire door leading into the steering compartment was adjusted by ships crew and proven operational and considered satisfactory. See Class Report uploaded to Documents.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 6 September 2022 Resolved
The system shall be supplemented by either a public address system, complying with the requirements of paragraph 7.2.2 of the Code or other suitable means of communication. Public address system on Deck 2 was intermittently operable. ABS Finding 1635.0
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2022
Resolved 12 September 2022
Resolution: An operational test of the public address system on 02 deck was carried out, loud and clear, and considered satisfactory. See Class report uploaded to Documents.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 September 2022 Resolved
The purpose of this regulation is to suppress and swiftly extinguish a fire in the space of origin. For this purpose, the following functional requirements shall be met: fire-extinguishing appliances shall be readily available. Fire station 21 had inoperable nozzle bale. ABS Finding 1635.0
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2022
Resolved 12 September 2022
Resolution: Fire station 21 nozzle was renewed, operationally tested and considered satisfactory. See Class report uploaded to Documents.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 12 October 2020 Resolved
46 CFR 92.05-1 / 16ac - CONSTRUCTION OF THE VESSEL SHALL BE SUCH AS TO MINIMIZE FIRE HAZARDS. AN APPROXIMATE 10" CRACK WAS INDENTIFIED IN THE MGO DAY TANK BOTTOM. THE CRACK IS ALONG A WELD SEAM WHERE THE TANK'S INBOARD LONGITUDINAL BULKHEAD MEETS THE TANK BOTTOM AND TRANSVERSE FRAME. COMPLETE APPROPRIATE REPAIRS TO CRACKED WELD.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 October 2020
Resolved 19 October 2020
Resolution: Repairs completed under ABS oversight.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 24 August 2020 Resolved
Not less than two lifebuoys shall be provided with lifebuoy self-activating smoke signals and be capable of quick release from the navigation bridge. Lifebuoys located on the port and stbd bridge wings were missing their quick release pins, thereby preventing quick release access. SOLAS (2014) III/7.1.3
Action required: 10 - Deficiency Rectified
Resolved 24 August 2020
Resolution: Quick release pins were properly replaced during the inspection.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 24 August 2020 Resolved
Structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these divisions shall be kept in good order so as to ensure their required performance if a fire occurs. Discovered air flowing through numerous A-60 door boundaries within the stair to house vertical zone. SOLAS (2014) II-2/14.2.1.1.1
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 September 2020
Resolution: Class verified the temporary repair of noted fire doors in staircase by fitting additional sealing gasket. Doors are to be repaired permanently to the satisfaction of the attending surveyor pending the order and arrival of new doors.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 August 2020 Resolved
Structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these divisions shall be kept in good order so as to ensure their required performance if a fire occurs. Discovered missing fire block for cable penetrations in the E-instruments room on O-1 deck. SOLAS (2014) II-2/14.2.1.1.1
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 September 2020
Resolution: Class verified that the fire block for cable penetrations was refitted, surveyed, and complete.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 27 July 2020 Resolved
Operational readiness. All life saving appliances shall be in working order and ready for immediate use. After bow only drop of lifeboat, padeye foundations examined when re-stowed. Transom edge behind aft hook had a 1-2" crack on centerline with freshly chipped paint at the edges. USCG, Class, Master and Chief Mate felt appropriate to have authorized service provider verify this was acceptable (cosmetic or surface) and not structural.(SOLAS 2009 Consolidated, CHIII Reg 20.2)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2020
Resolved 7 August 2020
Resolution: Corrected by Class
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 18 November 2019 Resolved
The construction of all doors and door frames in “A” class divisions, with means of securing them when closed, shall provide resistance to fire as to the passage of smoke and flame, as far as practicable, equivalent to that of the bulkheads in which the doors are situated. The Fire Screen Door for the interior ladder well to the navigation bridge (A-0) with installed security lock prevents door from sealing adequately against the threshold. Door should prevent passage of smoke and flame for one hour; current arrangement allows the passage of air from ladder well into the navigation bridge.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 December 2019
Resolved 16 December 2019
Resolution: Received documenatation (Finding Number 1564.0) from ABS attesting to the correction of the deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 18 November 2019 Resolved
The construction of all doors and door frames in “A” class divisions, with means of securing them when closed, shall provide resistance to fire as to the passage of smoke and flame, as far as practicable, equivalent to that of the bulkheads in which the doors are situated. The Fire Screen Door from the interior ladder well into Deck 6 (A-0) has an inoperable door latch, preventing the self-closing door from latching closed per design and requirement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 December 2019
Resolved 16 December 2019
Resolution: Received documenatation (Finding Number 1564.0) from ABS attesting to the correction of the deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 18 November 2019 Resolved
Each immersion suit or anti-exposure suits must be marked in such a way as to identify the person or vessel to which it belongs. AB Benoit’s immersion suit was not marked with the vessel’s name.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 December 2019
Resolved 16 December 2019
Resolution: Received documentation (Finding Number 1564.0) from ABS attesting to the correction of the deficiency.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 18 November 2019 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 December 2019
Resolved 6 January 2020
Resolution: Master completed crew change out.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 18 November 2019 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The bench grinder in the Bosun Locker does not have the required safety shield / guard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 December 2019
Resolved 16 December 2019
Resolution: Received documentation (Finding Number 1564.0) from ABS attesting to the correction of the deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 18 November 2019 Resolved
Satisfactory means (in the form of guard rails, lifelines, gangways, or underdeck passages) shall be provided for the protection of the crew in getting to and from their quarters, the machinery space, and all other parts used in the necessary work of the ship.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 December 2019
Resolved 19 November 2019
Resolution: Corrected, rails installed on the E/R platform after recent repair project.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 18 November 2019 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. The muster station and all associated fire-fighting appliances located adjacent to the incinerator space (protected by an active CO2 system) does not have proper boundary in the event of an accidental release of CO2 in to the space. SOLAS 2014, CH II-2, Reg. 14.2.1.2
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 December 2019
Resolved 16 December 2019
Resolution: Received documentation (Finding Number 1564.0) from ABS attesting to the correction of the deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 15 November 2019 Resolved
Containers, brackets, racks, and other similar stowage locations for life-saving equipment shall be marked with symbols in accordance with the recommendation of the Organization, indicating the devices stowed in that location for that purpose. 02 lifebuoy placards on the port side and 02 lifebuoy placards on the starboard side near adjacent to holds 3 and 5 were missing. SOLAS III(2014)/Reg 20.10
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2019
Resolved 18 November 2019
Resolution: Corrected.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Operational procedures for engines or equipment
Issued 4 August 2019 Resolved
Those ships using separate fuel oils to comply with paragraph 4 and entering or leaving an ECA shall have a procedure showing how fuel oil change over is done. Vessel shall update fuel oil system drawing and change over procedure to reflect valve alignments for operation on both HFO and MGO. MARPOL VI 14.6
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2019
Resolved 21 August 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 4 August 2019 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of present regulations. Diesel generator high pressure fuel oil supply relief valve shall be serviced and pop tested.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2019
Resolved 21 August 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 26 March 2019 Resolved
The main inlets and outlets of all ventilation systems shall be capable of being capable closed from outside the spaces being ventilated. Prove proper operation of/repairs of ventilation closures on pilothouse, steering gear, and cargo holds.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 27 March 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 March 2019 Resolved
Repair broken cable penetration on port lifeboat deck under ladder.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 27 March 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 26 March 2019 Resolved
Provide means for independent verification of lube oil pressure and engine RPM on ship's service diesel generators and emergency diesel generator.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 March 2019
01 - Certificates & Documentation › 013 - Documents › Unattended Machinery Spaces (UMS) Evidence
Issued 26 March 2019 Resolved
Provide approved PSTP for boiler flame failure.
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 March 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 December 2018 Resolved
Port anchor windlass system is inoperable making the port anchor unready for deployment
Action required: 17 - Rectify deficiencies prior to departure
Due 26 December 2018
Resolved 27 December 2018
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 11 December 2018 Resolved
Fire damper to #1 cargo hold sustained damage from container loading and is inop.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 December 2018
Resolution: Repaired to satisfaction of ABS surveyor.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 30 August 2018 Resolved
Inboard port side life raft was found to be improperly installed due to painter not being attached to hydrostatic weak link, but to lower frame link.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 30 August 2018
Resolution: Painter atteched to weak link on hydrostatic release, all sat.
Engineering › Diesel Engine (auxiliary) › Pump, High Pressure (fuel injection)
Issued 27 December 2017 Resolved
Make permanent repairs to #3 diesel generator and test IAW periodic test procedures.
Action required: 705 - Other - as specified
Due 28 December 2017
Resolved 28 December 2017
Resolution: Repairs completed and generator tested satisfactory.
Engineering › Fuel Oil Service System › Valve
Issued 8 August 2017 Resolved
Make permanante repairs to main engine fuel isolation valve. Prove proper operation.
Action required: 60 - Rectify deficiencies prior to movement
Due 8 August 2017
Resolved 8 August 2017
Resolution: Proper operation was proved. Fuel pressure dropped on the engine side of the valve.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 8 August 2017 Resolved
Make A-60 bulkhead in fan space located on aft house bulkhead as designed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 15 August 2017
Resolution: Recieved/reviewed ABS survey showing satisfaction of the above deficiency. Vessel is enrolled in ACP.
Engineering › Compressed Air System (start air) › Valve
Issued 24 April 2017 Resolved
Replace all relief valves for pressure vessels identified to be set above the maxium allowable working pressure. Tanks identified: HP Buffer tank, working air, control air, start air #1, start air #2, and emergency generator start air.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 August 2017
Resolved 15 August 2017
Resolution: Recieved/reviewed ABS survey showing satisfaction of the above deficiency. Vessel is enrolled in ACP.
Engineering › Compressed Air System (control) › Valve
Issued 24 April 2017 Resolved
Install new relief valves with a substantial lifting device.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 August 2017
Resolved 15 August 2017
Resolution: Recieved/reviewed ABS survey showing satisfaction of the above deficiency. Vessel is enrolled in ACP.
Engineering › Compressed Air System (start air) › Compressor
Issued 24 April 2017 Resolved
Replace relief valves for start air compressors (2nd stage relief valves)(33bar) and start air header (34 bar).
Action required: 705 - Other - as specified
Due 15 August 2017
Resolved 15 August 2017
Resolution: Recieved/reviewed ABS survey showing satisfaction of the above deficiency. Vessel is enrolled in ACP.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.