MAURY USCG vessel records Sign in
← All vessels

RAS MAERSK

RAS MAERSK is a 2003 tank ship. The Coast Guard has recorded 21 inspections since 2004, most recently in March 2014, along with 9 deficiencies and 5 operational controls.

Records from 2004 to 2014. Most recent: inspection, 8 March 2014.

Built
2003
Last inspected
8 March 2014
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9236999 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
671699
Flag
DENMARK
—
Maury page id
psix-671699

Inspections, by type

…with no type recorded9
Years with a record 6 calendar years (2004–2014)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it22184 - Convention (Subpart B), Gross Ton
9468 - Convention (Subpart B), Net Ton
29999 - Dead Weight, Ton
43716 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 21

8 March 2014 COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4809452
7 March 2014 ISPS I Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4811865
7 March 2014 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4812097
23 October 2008 COC-TVE Annual · Administrative Inspection · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3350181
31 October 2007 ISPS III Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3090737
30 October 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3090110
24 October 2007 COC-TVE Renew · ISM Exam · ISPS I Exam · PII Safety Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3085335
24 October 2007 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3086469
24 October 2007 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3086472
5 September 2006 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2769068
10 March 2006 ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2599802
5 August 2005 Type not recorded
No type recorded · Maritime Safety & Security Team New York (91106) · Activity 2452156
15 July 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2439298
30 May 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2373210
22 April 2005 COC-TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2340514
29 November 2004 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2250075
11 July 2004 ISPS II Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2128677
28 March 2004 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2033305
19 March 2004 Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2027327
16 March 2004 Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2025234
15 March 2004 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2024453

Deficiency record · 9

Engineering › Generator (propulsion/auxiliary-electric) › Battery
Issued 23 October 2008 Resolved
1499- Vessel's batteries for emergency generator have lost charge and cannot supply proper charge to start the emergency generator in the case of a loss of power.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 October 2008
Resolution: vessel has new batteries on board, batteries tested and working properly.
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 25 October 2007 Resolved
On 18Oct2007, while cleaning the oil discharge monitoring and control system, a glass tube in the system was broken renedering the system inoperative. Make proper repairs to the satisfaction of the IOPP certificate issuing authority prior to departure.
Action required: 705 - Other - as specified
Due 27 October 2007
Resolved 27 October 2007
Resolution: Per Vessel Classification Society Report dated 27OCT07: Repair parts have been ordered, conditional MARPOL certificate issued, ODME ops prohibited, retention of all contaminated water oboard via No. 7 Starboard/Slop tank for return voyage to Europe.
Construction/Loadline › Markings › Load Line Mark
Issued 25 October 2007 Resolved
The port and starboard loadlines are not easily identifyable due to rust. Paint the port and starboard loadlines in contrasting colors to the satisfaction of the ILLC issuing authority prior to 25Nov2007.
Action required: 705 - Other - as specified
Due 25 November 2007
Resolved 27 October 2007
Resolution: Per Vessel Class Report, 27Oct2007: Port and Starboard loadline marks have been repainted in contrasting color to vessel hull.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 25 October 2007 Resolved
The ship's freezer is inoperative. Make repairs to the satisfaction of the ship's flag state prior to departure.
Action required: 705 - Other - as specified
Due 27 October 2007
Resolved 27 October 2007
Resolution: Per Vessel Class Report 27Oct2007: Danish Maritime Authority granting single voyage back to Europe until repairs can be made to freezer; (3) 700 Litre chest type freezers provided for this voyage.
Communications › Radio Communications › EPIRB
Issued 25 October 2007 Resolved
The battery on the ship's EPIRB has expired. Provide a current battery for the EPIRB to the satifaction of the CSSR certificate issuing authority prior to departure.
Action required: 705 - Other - as specified
Due 27 October 2007
Resolved 27 October 2007
Resolution: Per Vessel Class Report 27Oct07: Vessels second EPIRB with battery expiration date of 31Oct2007 placed on bridge; Two new EPIRB''''s ordered to be delivered prior to 31OCT07; Both new EPIRBS clearing customs hold as of 27Oct07.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 24 October 2007 Resolved
While conducting a functional test on the oily water separator, the system could not properly demonstrate the recirculation/shut down function and it displayed an error code. Make proper repairs to the satisfaction of the IOPP issuing authority.
Action required: 705 - Other - as specified
Resolved 26 October 2007
Resolution: A relay in the system was identified as the problem and was replaced. The system was tested twice by USCG Marine Inspector with successful results.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 10 March 2006 Resolved
Support bracket for the Inert Gas Generator fuel nozzle housing is cracked at the bottom. Cite: SOLAS 74 A Ch. II-1/26.1
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 March 2006
Resolved 13 March 2006
Resolution: Witnessed swatisfactory repairs.
Navigation › Collision/Grounding Avoidance
Issued 15 March 2004 Resolved
ARPA labels missing, provide receipt for same prior to departing the port of NY. LEGACY COMPONENT DESC: Automatic Radar Plotting Aid (ARPA)
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 15 March 2004
Resolved 19 March 2004
Resolution: LABELS NOW AFFIXED TO THE SATISFACTION OF CLASS.
Pollution Prevention/Response › Prevention Equipment
Issued 15 March 2004 Resolved
ODME is not functional and must be repaired prior to departing the port of NY. LEGACY COMPONENT DESC: Cargo Monitor/Control System
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 March 2004
Resolved 19 March 2004
Resolution: ODME WAS TESTED AND FOUND SATISFACTORY BY CLASS.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.