Records from 2016 to 2025. Most recent: inspection, 23 October 2025.
Documentation record
Registered dimensions (L × B × D)39.8 ft × 13.4 ft × 5.2 ft
Registered tonnagegross 13 / net 8
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJ W NOLAN AND SONS · ERIE, PA, UNITED STATES · built 1950
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPORT CLINTON, OH
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 14 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Regulatory (Subpart C or D), Gross Ton
8 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 15
23 October 2025
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8259812
25 September 2025
In-Service Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8240928
15 July 2025
Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8186728
3 October 2024
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8013945
21 March 2024
Drydock Exam · Deficiency Check · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7882743
21 September 2023
Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7798053
11 August 2022
COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7530637
2 September 2021
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7302727
5 November 2020
Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7090218
24 October 2019
Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6841199
19 December 2018
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6602102
26 November 2018
Simplified Stability Test · Annual Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6589833
15 September 2017
Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6267056
17 August 2017
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6236000
13 September 2016
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6000790
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 21 March 2024
Resolved
Identified a crack approximately 8" in length on the weather deck stbd. side forward of the collision bulkhead and a pinhole on the stbd. bow weather deck forward of railing stanchion. Provide repair plan to local OCMI.
46 CFR 176.802
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 April 2024
Resolved 24 April 2024
Resolution: Operator made proper repairs to the deck to ensure watertight integrity.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 March 2024
Resolved
Identified a thruway in the collision bulkhead below the weather deck the was not water-tight. Provide a repair plan to local OCMI.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 April 2024
Resolved 24 April 2024
Resolution: Operator sealed the thru way to make the collision bulkhead watertight.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 September 2021
Resolved
#2 Cylinder fuel line found leaking. Replace with new line prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 September 2021
Resolved 9 September 2021
Resolution: Fuel line had been replaced and no fuel was observed leaking during an operational test.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 2 September 2021
Resolved
EPIRB Battery found expired. New EPIRB on order and due within a few days. Vessel must operate within 3 NM of shore until new unit arrives.
Action required: 705 - Other - as specified
Due 9 September 2021
Resolved 9 September 2021
Resolution: Battery had been replaced.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 24 October 2019
Resolved
Starboard side rudder post packing gland leaking water through to the inside of the rudder compartment. Repair/Replace by April 03, 2020.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 April 2020
Resolved 5 November 2020
Resolution: Verified the rudder packing was repaired during Annual Inspection. All Sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 October 2019
Resolved
Great Lakes Radio Certificate Expired August 2019. Provide a copy of the new certification by October 31, 2019.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 October 2019
Resolved 25 October 2019
Resolution: Vessel Owner provide copies of the Great Lkes Radio agreement Certificate valid until 08/2020
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 17 August 2017
Resolved
Six life jackets were in unserviceable condition; two needed retro-reflective material replaced and four had deteriorated foam fill.
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 August 2017
Resolved 17 August 2017
Resolution: Retro-reflective material was renewed on the two life jackets needing it and the four other life jackets with the deteriorated foam fill were removed from service and replaced.
Engineering › Lubricating Oil Service System › Gauge
Issued 17 August 2017
Resolved
Engine oil pressure gauges did not work at the operating station.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 15 September 2017
Resolution: Oil pressure gauges now operational.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 17 August 2017
Resolved
Portable fire extinguisher at operating station needs to be placed in an approved bracket.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 15 September 2017
Resolution: Proper bracket has been installed.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 13 September 2016
Resolved
Provide current navigational chart for your vessels area of operation.
Due 19 September 2016
Resolved 21 September 2016
Resolution: Current chart was provided and placed onboard vessel.
Construction/Loadline › Structures › Door
Issued 13 September 2016
Resolved
Provide captive chains or similar device on all watertight hatches in accordance with 46CFR171.124(b)
Due 19 September 2016
Resolved 21 September 2016
Resolution: Captive chains were insatlled on watertight hatches.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 13 September 2016
Resolved
Replace cracked water light on starboard side life float.
Due 19 September 2016
Resolved 21 September 2016
Resolution: Approved water light was installed to replace cracked light found during inspection.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 13 September 2016
Resolved
Install bilge high water level alarm in aft compartment (steering/fuel tank space) ensuring the alarm is tied into existing visual and audible alarm feature.
Due 19 September 2016
Resolved 21 September 2016
Resolution: High water level alarm was installed and tested. Visual and audible alarm verified.