CLIPPER MOON is a 2003 tank ship. The Coast Guard has recorded 32 inspections since 2016, most recently in April 2025, along with 7 deficiencies and 6 operational controls.
Records from 2016 to 2025. Most recent: inspection, 25 April 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it11053 - Regulatory (Subpart C or D), Net Ton 35012 - Convention (Subpart B), Gross Ton 11053 - Convention (Subpart B), Net Ton 44822 - Dead Weight, Ton 60681 - Displacement, Ton 35012 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page
32 inspections, each with its date, unit and type; 7 deficiencies with the resolution recorded against each; 6 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
PlansSign in
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 28 February 2023Resolved
On ships carrying flammable or toxic products or both, a water-spray system for cooling, fire prevention and crew protection should be installed to cover: boundaries of superstructures and deck houses normally manned, cargo compressor rooms, cargo pump room, storerooms containing high fire risk items and cargo control room, all facing the cargo area.
Marine Inspector witnessed a total of 17 nozzles on compressor room clogged; 4 aft, 5 starboard, 8 forward. As well as 9 nozzles clogged on middle row of superstructure.
74 SOLAS (2020) VII/13.1
IGC (93) 11.3.1.4
40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 28 February 2023
Resolved 21 March 2023
Resolution: Evidence of installation of new nozzles and piping system on superstructure was recieved. Attached class survey as well as video into deficiency documents.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 February 2022Resolved
Lighting Fittings should have pressurized fittings and enclosed or be of the flame proof type. PSCO observed 04 cracked light enclosures in the cargo machinery room.
74SOLAS(20)/13.1
IGC Code(93) 10.2.4.1
17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 21 February 2022
Resolved 20 February 2022
Resolution: Received photos of 4 newly installed LED light enclosures inside cargo machinery room.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 20 February 2022Resolved
For the spaces listed in 13.6.7 alarms should be activated for flammable products when the vapor concentrations reach 30% of the lower flammable limit. PSCO observed the fixed gas sampling system was reading the lower flammable limit incorrectly due to not being calibrated correctly. The span gas is propane with 35% LEL and the system was reading 40% LEL.
74SOLAS(20)VII 13.1
IGC Code(93) 13.6.10
10c
Action required: 10 - Deficiency Rectified
Due 20 February 2022
Resolved 20 February 2022
Resolution: Crew calibrated system. All sat.
A gas carrier shall comply with the requirements of the International Gas Carrier Code. Airlock doors should be self-closing and without any holding back arrangements. Outside airlock door was disconnected from self-closing arrangement. 74SOLAS(14)VII/13.1; IGC 93/3.6.2
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 12 February 2021
Resolved 12 February 2021
Resolution: Crew members reconnected self-closing arrangment on outside airlock door.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 27 October 2020Resolved
Changes in set pressures should be recorded in the ship's log and a sign posted in the cargo control room, if provided, and at each relief valve, stating the set pressure. Pressure relief valve signs on all tank domes were incorrect. Some had one relief valve marked at one setting but the other was marked as their seperate setting. 74SOLAS(14)VII/13.1 & IGC Code(1993)8.2.7.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 27 October 2020
Resolved 27 October 2020
Resolution: PSCO observed crew correct all pressure relief valve signs.
PSCO observed that the IOPP Form A lists that the vessel has a MEPC.60(33) oily water separator and oil content meter installed, but upon inspection of the OWS and OCM it was found that a MEPC.107(49) OWS and OCM are installed.
Action required: 10 - Deficiency Rectified
Resolved 26 December 2018
Resolution: Corrected IOPP issued by class while PSCO was still on board.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 December 2018Resolved
PSCO identified a strong cargo smell and recorded 56% LEL when standing in vacinity of No.1 cargo compressor. Identify and correct source of smell and high LEL prior to cargo operations.
Update 27 Dec 18: Make permanent repairs to equipment as identified by attending RO surveyor. (40 a,c)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 January 2019
Resolution: Cleared per attached class report
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.