RIO PARA

RIO PARA is a 2003 freight ship. The Coast Guard has recorded 22 inspections since 2004, most recently in October 2014, along with 7 deficiencies and 6 operational controls.

Records from 2004 to 2014. Most recent: inspection, 30 October 2014.

Built
2003
Last inspected
30 October 2014
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9262015 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
672459
Flag
ANTIGUA AND BARBUDA
—
Maury page id
psix-672459

Inspections, by type

…with no type recorded12
Years with a record 7 calendar years (2004–2014)
The 22 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it4462 - Regulatory (Subpart C or D), Gross Ton
4370 - Convention (Subpart B), Gross Ton
2132 - Convention (Subpart B), Net Ton
5600 - Dead Weight, Ton
8567 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 22

30 October 2014 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5015077
15 October 2010 PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3870391
14 October 2010 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3869943
11 January 2010 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3662199
23 February 2009 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3422210
12 October 2008 PII Safety Exam · ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3343058
1 October 2008 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3336400
11 July 2008 ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3264779
19 January 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3133081
23 September 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3063954
29 March 2007 PII Safety Exam · Administrative Inspection · ISPS II Exam · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2897328
5 March 2007 Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2881880
3 March 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2881338
23 September 2006 Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2785311
21 September 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2784044
10 September 2006 Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2861240
8 September 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2773154
27 April 2006 ISPS II Exam · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2638524
28 March 2006 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2618384
25 March 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2609366
16 March 2004 Passenger/Freight Vessel Examination · MARPOL Annex V Examination · Security Inspection · MARPOL Annex I Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2025762
13 March 2004 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2048525

Deficiency record · 7

Deck/Cargo › Mooring/Anchoring › Capstan
Issued 31 October 2014 Resolved
1330 - Winches and Capstans - The condition of the ship and it's equipment shall be maintained to conform with the present regulations and will remain fit to proceed to sea without danger. Vessel's port capstan is inoperable and has been sent off the vessel for repair - 74 SOLAS 09 cons. I/11.A
Action required: 705 - Other - as specified
Due 30 November 2014
Resolved 17 December 2014
Resolution: Verified proper operation of the vessel''s port capstan.
Electrical › Electric Generation Source (emergency) › Generator
Issued 31 October 2014 Resolved
1430 - Auxiliary Engines - Oil fuel pipes, valves, and fittings shall be of steel or other approved material. Emergency generator fuel supply line leading into the fuel strainer was repaired using a soft patch - 74 SOLAS 97 cons. II-2/15.2.8
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 November 2014
Resolved 4 December 2014
Resolution: Vessel provided Class Report attesting to the satisfactory repairs of the following system. Affected fuel line was removed and replaced with new line.
Deck/Cargo › Holds/Tanks › Ventilation Air Intake
Issued 31 October 2014 Resolved
1275 - Ventilation Air Pipes- The main inlets and outlets of all ventiliation systems shall be capable of being closed. Cargo hold #2 Aft vent severely wasted with hole - 74 SOLAS 97 cons. II-2/16.9
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 November 2014
Resolution: Conducted Def Check on Vessel, hole in vent has been repaired with clad weld.
Fire Fighting › International Shore Connection › Connection
Issued 12 October 2008 Resolved
Request VSL, stations the international shore connection within the vicinity of the fire main connection for easy access.
Action required: 705 - Other - as specified
Due 26 October 2008
Resolved 9 March 2009
Resolution: International shore connection has now been moved. Vessel was recommended, during their next class survey, to have class address the location of placement and make appropriate changes to the fire plan.
Navigation › Emergency Steering › Compass Reading for Emergency Steering
Issued 12 October 2008 Resolved
request vessel to post steering block diagram on bridge.
Action required: 705 - Other - as specified
Due 19 October 2008
Resolved 9 March 2009
Resolution: Steering block diagram has been installed in place on the bridge.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 1 October 2008 Resolved
Owner/operator has not received required authorization to operate on the navigable waters of the U.S. Nontank Vessel Response plans must meet the required elements IAW 33 USC 1321(j)(5)(D) for each Geographic Specific Area in which it operates.
Action required: 705 - Other - as specified
Due 31 October 2008
Resolved 9 March 2009
Resolution: Non-tank Vessel Response Plan authorization letter filed with plan and approved for several COTP zones with appropriate contact information for each zone/port.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 29 March 2007 Resolved
Food ration provisions found on freefall lifeboat were not air tight and were contaminated by air so they are considered expired.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 March 2007
Resolved 30 March 2007

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.