← All vessels
RIO PARA
RIO PARA is a 2003 freight ship. The Coast Guard has recorded 22 inspections since 2004, most recently in October 2014, along with 7 deficiencies and 6 operational controls.
Records from 2004 to 2014. Most recent: inspection, 30 October 2014.
- Built
- 2003
- Last inspected
- 30 October 2014
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 7 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9262015 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V2BU9
672459
Flag
ANTIGUA AND BARBUDA
—
Maury page id
psix-672459
Inspections, by type
The 22 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it4462 - Regulatory (Subpart C or D), Gross Ton
4370 - Convention (Subpart B), Gross Ton
2132 - Convention (Subpart B), Net Ton
5600 - Dead Weight, Ton
8567 - Displacement, Ton
4370 - Convention (Subpart B), Gross Ton
2132 - Convention (Subpart B), Net Ton
5600 - Dead Weight, Ton
8567 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 22
30 October 2014
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5015077
15 October 2010
PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3870391
14 October 2010
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3869943
11 January 2010
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3662199
23 February 2009
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3422210
12 October 2008
PII Safety Exam · ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3343058
1 October 2008
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3336400
11 July 2008
ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3264779
19 January 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3133081
23 September 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3063954
29 March 2007
PII Safety Exam · Administrative Inspection · ISPS II Exam · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2897328
5 March 2007
Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2881880
3 March 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2881338
23 September 2006
Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2785311
21 September 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2784044
10 September 2006
Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2861240
8 September 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2773154
27 April 2006
ISPS II Exam · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2638524
28 March 2006
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2618384
25 March 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2609366
16 March 2004
Passenger/Freight Vessel Examination · MARPOL Annex V Examination · Security Inspection · MARPOL Annex I Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2025762
13 March 2004
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2048525
Deficiency record · 7
Deck/Cargo › Mooring/Anchoring › Capstan
Issued 31 October 2014
Resolved
1330 - Winches and Capstans - The condition of the ship and it's equipment shall be maintained to conform with the present regulations and will remain fit to proceed to sea without danger. Vessel's port capstan is inoperable and has been sent off the vessel for repair - 74 SOLAS 09 cons. I/11.A
Electrical › Electric Generation Source (emergency) › Generator
Issued 31 October 2014
Resolved
1430 - Auxiliary Engines - Oil fuel pipes, valves, and fittings shall be of steel or other approved material. Emergency generator fuel supply line leading into the fuel strainer was repaired using a soft patch - 74 SOLAS 97 cons. II-2/15.2.8
Deck/Cargo › Holds/Tanks › Ventilation Air Intake
Issued 31 October 2014
Resolved
1275 - Ventilation Air Pipes- The main inlets and outlets of all ventiliation systems shall be capable of being closed. Cargo hold #2 Aft vent severely wasted with hole - 74 SOLAS 97 cons. II-2/16.9
Fire Fighting › International Shore Connection › Connection
Issued 12 October 2008
Resolved
Request VSL, stations the international shore connection within the vicinity of the fire main connection for easy access.
Navigation › Emergency Steering › Compass Reading for Emergency Steering
Issued 12 October 2008
Resolved
request vessel to post steering block diagram on bridge.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 1 October 2008
Resolved
Owner/operator has not received required authorization to operate on the navigable waters of the U.S. Nontank Vessel Response plans must meet the required elements IAW 33 USC 1321(j)(5)(D) for each Geographic Specific Area in which it operates.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 29 March 2007
Resolved
Food ration provisions found on freefall lifeboat were not air tight and were contaminated by air so they are considered expired.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.