MAURY USCG vessel records Sign in
← All vessels

KYRIAKOULA

KYRIAKOULA is a 2003 tank ship. The Coast Guard has recorded 38 inspections since 2004, most recently in December 2017, along with 18 deficiencies and 6 operational controls.

Records from 2004 to 2017. Most recent: inspection, 11 December 2017.

Built
2003
Last inspected
11 December 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9265720 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
672577
Flag
LIBERIA
—
Maury page id
psix-672577

Inspections, by type

…with no type recorded12
Years with a record 11 calendar years (2004–2017)
The 38 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it40680 - Convention (Subpart B), Gross Ton
20376 - Convention (Subpart B), Net Ton
72354 - Dead Weight, Ton
86148 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 38

11 December 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6322061
24 October 2017 Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6293207
5 October 2017 COE-Administrative
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6281908
1 October 2017 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6278824
8 May 2017 COE-Dockside
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6136345
29 October 2016 Ballast Water Examination · ISPS II Exam · COC-TVE Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6026985
31 July 2016 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5958113
25 September 2015 COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5728905
10 July 2012 ISPS III Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4374007
9 July 2012 COE-Dockside
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4372912
6 July 2012 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4369592
7 May 2012 COE-Dockside
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4304292
13 August 2011 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4114359
6 August 2011 Ballast Water Examination · ISPS I Exam · COC-TVE Annual
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4103936
16 July 2009 MARPOL Annex VI Survey · COC-TVE Annual · MARPOL Annex I Examination · ISPS III Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3525744
15 January 2009 ISPS I Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3394549
12 January 2009 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3392710
11 September 2008 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3322671
7 May 2008 Ballast Water Examination · COC-TVE Renew · ISPS III Exam · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3197873
11 June 2007 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2958709
29 May 2007 ISPS II Exam · COC-TVE Annual · Deficiency Check · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2944534
28 May 2006 Type not recorded
No type recorded · Maritime Safety & Security Team LA/LB (91103) · Activity 2662700
26 May 2006 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2659768
10 April 2006 Ballast Water Examination · COC-TVE Renew · ISPS III Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2621972
12 October 2005 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2512535
15 September 2005 ISPS II Exam · NPV Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2493187
6 May 2005 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2351221
11 April 2005 Ballast Water Examination · COC-TVE Annual
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2331589
1 March 2005 NPV Safety Exam
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2301255
23 December 2004 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2264152
26 September 2004 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2205086
10 August 2004 Ballast Water Examination · ISPS II Exam
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2145396
30 July 2004 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2150548
28 July 2004 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2186458
28 July 2004 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2221656
31 March 2004 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2034985
23 March 2004 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2029541
23 March 2004 Certificate of Compliance
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2029606

Deficiency record · 18

Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 24 October 2017 Resolved
1830-Vessel unable to prove proper operation of the #2 COP emergency shutdown from the manifolds or cargo control room. Vessel is prohibited from using #2 COP to discharge cargo. 33 CFR 155.780. Prior to cargo. ac
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 October 2017
Resolved 11 December 2017
Resolution: PSC NOLA received a class report from ABS satisfying the requirement.
Lifesaving › Rocket Parachute Flares › General
Issued 24 October 2017 Resolved
0640-Navigation bridge contained only 09 parachute flares. Vessel stated they were expended during a previous pirate attack. 74SOLAS(14) III/6.3 17ac
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 24 October 2017
Resolved 27 October 2017
Resolution: Vessel provided documentation that flares were purchased and delivered to the vessel.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 24 October 2017 Resolved
1730-PSCO noted OWS overboard discharge piping was wasted and holed. 74SOLAS(14) I/11. 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 24 October 2017
Resolved 11 December 2017
Resolution: PSC NOLA received a class report from ABS satisfying the requirement.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 29 May 2007 Resolved
Garbage Management Plan is not properly implemented in engine room and areas in accomodation space. Garbage is segregated properly, but color code scheme for waste cans are not the same as in the plan. Plan also identifies a garbage grinder that the ship does not have. Update/ implement plan to class/flag satisfaction.
Action required: 705 - Other - as specified
Due 12 June 2007
Resolved 11 June 2007
Resolution: Received class report attesting to the corrections made to the vessel''s Garbage Management Plan. Class report is in case documentation.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 29 May 2007 Resolved
High level / overfill alarm must be indicated in black letters beneath the alarm apparatus. Letters have been painted over and are barely visible from the main deck. Address the satisfaction of class/flag.
Action required: 705 - Other - as specified
Due 5 June 2007
Resolved 6 June 2007
Resolution: Received class report detailing that letters had been painted appropriately to the satisfaction of class representative.
Documentation › Safety Management System › Reports and Analysis Procedures
Issued 29 May 2007 Resolved
No reports were made to the company / DPA for the following patches / temporary repairs: 1) Stbrd side low temperature cooling pipe (lower level engine room) 2) OWS pump fresh water suction pipe. Rectify to the satisfaction of class / flag .
Action required: 705 - Other - as specified
Due 12 June 2007
Resolved 11 June 2007
Resolution: Received class report attesting to the repairs made to soft patches found in the engine room. Class survey report is in case documentation.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 29 May 2007 Resolved
3 food rations (required by LSA Code ch. 4/4.4.8.12) in port lifeboat have lost their vacuum seal. Loss of seal may cause rations to mold/rot. Replace to satisfaction of class/flag.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 May 2007
Resolution: Received class report indicating that additional rations were taken on board prior to vessel''''s departure from the San Francisco Bay.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 29 May 2007 Resolved
Fire fighting outfit pants (required by FSS Code 2.1.1.1) are in disrepair and may not adequately protect the skin from heat. Deteriorated laminate from pants is peeling away. Replace to the satisfaction of class/flag.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 May 2007
Resolution: Received class report indicating that an additional suit was obtained prior to vessel''s departure from port.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 11 April 2006 Resolved
Two fire fighting suits pants deteriorated. Laminate from pants is peeling off. Replace suits 74Solas II-2 Reg 10.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 May 2006
Resolution: Rcvd fax reciept for 3 new firefighting suits.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 April 2006 Resolved
Self igniting light on lifebuoy on port side amid ship has corroded battery and does not ignite. Replace light. 74Solas III Reg 7.1.3
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 May 2006
Resolution: Rcvd fax reciept for purchase of new batteries for the self igniting light.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 11 April 2006 Resolved
Number 3 cargo pump does not work properly in accordance with emergency stopping procedures. Vessel is not authorized to use #3 cargo pump during discharge operations until repairs made to the satisfaction of class. 33CFR155.780
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 May 2006
Resolution: Rcvd fax of class report stating No. 3 Cargo Oil Pump has been repaired and is now working properly.
Deck/Cargo › Inert Gas System › Venting System
Issued 15 September 2005 Resolved
IGS Oxygen Analyzer is Inoperable. Repair to the satisfaction of Class Society. Crew is to make routine rounds of the IGS & log O2 Content of IGS Output. Must be fixed prior to next US port.
Action required: 705 - Other - as specified
Resolved 12 October 2005
Resolution: Received a class report stating that the IGS system was in proper operation.
Lifesaving › Lifeboat Equipment
Issued 23 March 2004 Resolved
14 lifeboat food ration packages not properly sealed. LEGACY COMPONENT DESC: Food Ration
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 March 2004
Resolution: Recieved fax report correcting food rations.
Deck/Cargo › Holds/Tanks
Issued 23 March 2004 Resolved
Both combustible gas meters not operating properly LEGACY COMPONENT DESC: Portable Gas Measuring Equipment
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 March 2004
Resolution: Recieved fax technical report of service on portable gas measuring equipment.
Fire Fighting › Structural - A Class Divisions
Issued 23 March 2004 Resolved
3 firedoors did not properly self close LEGACY COMPONENT DESC: Openings - Fire Doors
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 23 March 2004
Resolution: Ship''s crew made proper repairs prior to boarding team departing ship
Fire Fighting › Self-contained Breathing Apparatus
Issued 23 March 2004 Resolved
EEBD in lower level of cargo pump room was not properly charged
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 March 2004
Resolution: Replaced EEBD with a properly charged one prior to departing ship after boarding.
Deck/Cargo › Vapor Control Systems
Issued 23 March 2004 Resolved
Provide proof from Class society that vessels vapor collection system meets 46 CFR part 39 and Title 33 CFR section 155.750(d). Also verify completion of outstanding class society review comments (ABS submittal 362894YH). LEGACY COMPONENT DESC: Vapor Recovery Unit
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 March 2004
Resolution: Recieved fax from Class Society that states the vessel collection system meets 46 CFR 39 and 33 CFR 155.750(d).
Documentation › Manuals/Policy Documentation
Issued 23 March 2004 Resolved
Provide oil transfer procedures are to meet requirements of 33 CFR 155.730 LEGACY COMPONENT DESC: Transfer Procedures
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 March 2004
Resolution: Ship has approved transfer procedures onboard

Ownership record