MAURY USCG vessel records Sign in
← All vessels

CABO SOUNION

CABO SOUNION is a 2004 tank ship. The Coast Guard has recorded 35 inspections since 2004, most recently in March 2014, along with 7 deficiencies and 10 operational controls.

Records from 2004 to 2014. Most recent: inspection, 12 March 2014.

Built
2004
Last inspected
12 March 2014
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9275737 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
672606
Flag
MARSHALL ISLANDS
—
Maury page id
psix-672606

Inspections, by type

…with no type recorded20
Years with a record 10 calendar years (2004–2014)
The 35 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it40038 - Convention (Subpart B), Gross Ton
20190 - Convention (Subpart B), Net Ton
82849 - Displacement, Ton
69636 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 35

12 March 2014 Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4811183
7 February 2012 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4240347
12 August 2011 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4113784
20 February 2010 Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3681853
26 January 2010 COE-Offshore · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3670414
10 July 2009 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3530520
26 March 2009 ISPS II Exam · COC-TVE Annual · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3440342
20 March 2009 COE-Dockside
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3437352
18 July 2008 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3272030
16 July 2008 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3269365
6 July 2008 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3258937
2 July 2008 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3255063
25 April 2008 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3196796
23 February 2008 COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3151970
19 December 2007 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3118378
28 September 2007 Ballast Water Examination · ISPS II Exam · COC-TVE Annual
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3067610
25 September 2007 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3066116
20 February 2007 Random ISPS/MTSA-No PSC
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2874611
30 October 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2810503
27 October 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2809624
27 September 2006 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2788623
24 September 2006 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2785932
20 March 2006 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2605622
20 March 2006 COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2607035
21 September 2005 Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2497887
11 August 2005 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2459313
5 August 2005 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2452844
28 June 2005 COC-TVE Annual · ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2406018
8 March 2005 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2305617
8 February 2005 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2288554
20 December 2004 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2262761
17 December 2004 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2261582
14 August 2004 ISPS II Exam · Ballast Water Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2165901
20 March 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2031253
19 March 2004 Tank Vessel Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2027692

Deficiency record · 7

Documentation › Certificates/Documents › International Air Pollution Prevention Certificate
Issued 12 March 2014 Resolved
MARPOL 2011 cond. ANNEX VI Reg. 6.1 - An IAPP certificate shall be issued after an initial or renewal survey in accordance with the provisions of Regulation 5. Vessel does not have a valid/issued IAPP on board. 40(a)(c)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 March 2014
Resolution: A new IAPP Certificate was issued by ABS and delivered to the ship. The certificate has been scanned and entered into documents.
Navigation › Collision/Grounding Avoidance › Radar
Issued 12 August 2011 Resolved
Vessel requested inbound LOD for the COTP zone LA/LB. A techincian has been scheduled to attend the vessel while in port.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 August 2011
Resolution: CLASS REPORT SHOWED THAT X-BAND RADAR WAS REPLACED WITH A NEW, TYPE-APPROVED 3CM RADAR SYSTEM
Deck/Cargo › Vapor Control Systems › Fixed Vapor Collection Arms
Issued 26 March 2009 Resolved
1199 - Other (Cargo) - Vessel's port side vapor control line flanges on cargo manifold are missing the required studs at the top of each flange. Each vapor flange is required to have a one inch long, 0.5 inch diameter stud at the top of the flange. Vessel needs to install studs in all vapor control line flanges on both manifolds to the satisfaction of Coast Guard. 46CFR39.20-1(e)
Action required: 705 - Other - as specified
Due 9 April 2009
Resolved 10 July 2009
Resolution: Received proper documentation satisfying the requirement.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 28 September 2007 Resolved
Vessel is using Gamazine for the sewage treatment plant instead of chlorine. Chlorine is the only chemical mentioned in the manufacturer's manual. Verification is to be provided by the manufacturer and class that the use of Gamazine vice chlorine is acceptable. Note: No chlorine test kit on board for required weekly testing.
Action required: 15 - Rectify deficiencies by next port
Resolved 29 October 2007
Resolution: Sodium Hypoclorite is now being used for the MSD and a test kit has been placed on board.
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 28 September 2007 Resolved
Vessel is not using the ballast water handling log as per ballast water management plan. Sediment has not been recorded by previous chief officers.
Action required: 705 - Other - as specified
Resolved 28 September 2007
Resolution: Discussed with Master and current [name withheld] about starting recording procedures.
Navigation › Collision/Grounding Avoidance › Automatic Radar Plotting Aid (ARPA)
Issued 25 September 2007 Resolved
Received notification that the 3cm radar onboard the vessel is inoperable. Vessel must have a certified technician make repairs and fax a copy of the report to the USCG.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2007
Resolution: Received satisfactory tech report that repairs have been made.
Engineering › Freshwater System (jacketwater cooling) › Suction Strainer
Issued 30 October 2006 Resolved
Vessel suffered a "Compromise of propulsion/power"
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 October 2006
Resolution: Normal function was restored prior to docking, after suction strainers were cleaned. Suction strainers were found to be heavily clogged with fish. ABS submitted class report attesting that machinery is operating properly.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.