MAR ALMUDENA is a 1994 tank ship. The Coast Guard has recorded 16 inspections since 2004, most recently in February 2006, along with 28 deficiencies — 1 with no resolution recorded — and 1 operational control.
Records from 2004 to 2006. Most recent: inspection, 24 February 2006.
- Built
- 1994
- Last inspected
- 24 February 2006
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 28 recorded · 1 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9088938 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9HJT9
673252
Flag
SPAIN
—
Maury page id
psix-673252
Inspections, by type
The 16 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it4762 - Convention (Subpart B), Gross Ton
5942 - Simplified, Gross Ton
2818 - Convention (Subpart B), Net Ton
2818 - Simplified, Net Ton
12558 - Displacement, Ton
9776 - Dead Weight, Ton
5942 - Simplified, Gross Ton
2818 - Convention (Subpart B), Net Ton
2818 - Simplified, Net Ton
12558 - Displacement, Ton
9776 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 16
24 February 2006
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2591094
24 February 2006
Deficiency Check · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2591508
23 February 2006
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2590926
18 October 2005
Random ISPS/MTSA/PSC
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2516966
13 August 2005
ISPS II Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2461597
9 May 2005
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2353239
19 April 2005
Ballast Water Examination · COC-TVE Annual · MARPOL Annex I Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2338561
20 February 2005
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2297918
5 August 2004
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2156687
5 August 2004
Random ISPS/MTSA/PSC
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2161285
1 July 2004
ISPS II Exam
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2117614
29 June 2004
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2139391
5 May 2004
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2058761
28 April 2004
Administrative Inspection · Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2054654
24 March 2004
MARPOL Annex I Examination · Certificate of Compliance
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2029846
23 March 2004
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2029754
Deficiency record · 28
Operations/Management › Pollution › Compliance with Transfer Procedures
Issued 18 October 2005
Resolved
Provide Oil Transfer Procedures to comply with U. S. regulations, 33 CFR 155.700. Current bunkering procedures lack required info and are not indexed or X-referenced correctly.
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 19 April 2005
Resolved
Oil discharge monitoring equipment not operational. Device displays "Communication Error". To satisfaction of Class and Administration.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 19 April 2005
Resolved
Gangway accomodation ladder damaged by high seas. Master plans to Maintain 01 ladder. Provide aproval from flag state or Class that this is acceptable permanently. To the satisfaciton of Class and Administration.
Deck/Cargo › Cargo Heating › General
Issued 19 April 2005
Resolved
Valve handles for (02) for the thermal oil inlet ad outlet piping, fwd of the cargo pump room are missing and wasted. Renew Valve.To satisfaction of Class.
Deck/Cargo › Cargo Heating › General
Issued 19 April 2005
No resolution recorded
Heat shields for the thermal oil inlet and outlet valve piping and the stbd side discharge valve piping to the stbd manifold missing. To satisfaction of Class
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 19 April 2005
Resolved
Numerous Ladder rungs throught the ship are wasted and are a safety hazard. Renew all wasted (stair ) lungs.
Deck/Cargo › Ballast › Interface Detector
Issued 19 April 2005
Resolved
There are open wires on the Port and Stbd sides at unused transmitters for each Ballast tank. Repair the connection or remove the open wires.
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 19 April 2005
Resolved
Numerous lights in the cargo pump room do not have proper securing device where the cable enters the light housing. Provide proper electrical connections for each unsat light.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 19 April 2005
Resolved
Safe acces to te Bow does not apear to provide an equivalent of safety for bow acces. Provide statement from class society or flag state the current arrangement is satisfactory.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 19 April 2005
Resolved
Fire detection system in each Fwd locker space is inoperable. Make system operational or remove the system.
Documentation › Certificates/Documents › IOPP Certificate
Issued 19 April 2005
Resolved
Entries on section 5 of the IOPP certificate are incomplete.Indicate whether SBT or PI and regulations 13F and 13G apply to this vessel. To satisfaction of class
Lifesaving › Hand Flares › Not on Board
Issued 19 April 2005
Resolved
01 Hand Flare missing vessel must have 12 and only 11 are onboard.
Navigation › Electronic Positioning › GPS/DGPS Receiver
Issued 19 April 2005
Resolved
The securing Pin for the EPIRB located on the stbd side aft of the Bridge is broken rendering the epirb free to roll about. secure properly
Fire Fighting › Structural - A Class Divisions
Issued 24 March 2004
Resolved
Remove holdback hook from FSD #C-03 and T-02. LEGACY COMPONENT DESC: Openings - Fire Doors
Fire Fighting › Structural - A Class Divisions
Issued 24 March 2004
Resolved
Repair/Replace magnetic holdback devices on FSD B01 and B02 or keep doors closed at all times. LEGACY COMPONENT DESC: Openings - Fire Doors
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 24 March 2004
Resolved
Conduct a static liquid pressure test of transfer/bunkering system. LEGACY COMPONENT DESC: Transfer Hose
Documentation › Manuals/Policy Documentation
Issued 24 March 2004
Resolved
Provide bunker/oil transfer procedures. LEGACY COMPONENT DESC: Transfer Procedures
Documentation › Certificates/Documents
Issued 24 March 2004
Resolved
Flag state to update the minimum safe manning document to include required GMDSS operators (if any) LEGACY COMPONENT DESC: Minimum Safe Manning Document
Fire Fighting › International Shore Connection
Issued 24 March 2004
Resolved
Vessel has two international shore connections, vessel to provide an additional 4 washers to each ISC. LEGACY COMPONENT DESC: Washers
Fire Fighting › International Shore Connection
Issued 24 March 2004
Resolved
Vessel's fwd international shore connection requires new gasket. LEGACY COMPONENT DESC: Gasket
Fire Fighting › International Shore Connection
Issued 24 March 2004
Resolved
Vsl's ISC needs to be stowed IAW fire control plan or fire control plan needs to be updated to indicate ISC's current location.
Accommodation/Occupational Safety › Occupational Safety
Issued 24 March 2004
Resolved
Vsl to properly stow all compressed gas bottles.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 24 March 2004
Resolved
Flag state/class to verify repairs to heat shield on cargo line into cargo manifold. Repairs to be done as original. LEGACY COMPONENT DESC: Piping
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 24 March 2004
Resolved
Vsl to repair heat shield on thermal oil line located on main deck port side. Class/Flag to provide report of proper repairs. LEGACY COMPONENT DESC: Piping
Navigation › Piloting/Steering
Issued 24 March 2004
Resolved
Vsl to acquire a U.S. Coast Pilot [name withheld] COMPONENT DESC: US Coast Pilot
Documentation › Manuals/Policy Documentation
Issued 24 March 2004
Resolved
Class to review Cargo/Ballast manual and provide stamp of approval (if approved). LEGACY COMPONENT DESC: Cargo/Ballast System Instruction Manual
Communications › Alarms/Indicators
Issued 24 March 2004
Resolved
Vsl's general alarm does not work. Vsl to repair alarm to original. LEGACY COMPONENT DESC: General Alarm
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 24 March 2004
Resolved
Vsl has a leak on the port cargo line in the cargo pumproom. Vsl to isolate port cargo line and use only starboard line to discharge or load cargo. Vsl to make permament repairs. Flag/Class to attend vsl to verify repairs. A written report to be submitted to MSO [name withheld] attesting to proper repairs LEGACY COMPONENT DESC: Transfer Hose