REN JIAN 19

REN JIAN 19 is a 2004 freight ship. The Coast Guard has recorded 5 inspections since 2016, most recently in January 2023, along with 3 deficiencies.

Records from 2016 to 2023. Most recent: inspection, 3 January 2023.

Built
2004
Last inspected
3 January 2023
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 3 January 2023
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2016–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9280809
674338
Flag
CHINA
Maury page id
psix-674338

Documentation record

Tonnage as PSIX records it55495 - Dead Weight, Metric Ton
72273 - Displacement, Metric Ton
40952 - Convention (Subpart B), Gross Ton
40952 - Regulatory (Subpart C or D), Gross Ton
25095 - Convention (Subpart B), Net Ton
25095 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

STAR MINERVA Public Freight · MISLE 962748 · 1 August 2016 · activity 5970466BOCHEM LUXEMBOURG Tank Ship · MISLE 1370999 · 1 August 2016 · activity 5970466

Inspection history · 5

3 January 2023 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7615712
25 January 2022 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7385254
1 August 2016 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5970466
29 July 2016 Deficiency Check · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5956558
4 May 2016 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5868668

Deficiency record · 3

Engineering › Fuel Oil Service System › Filter
Issued 4 May 2016 Resolved
Wash-back filter IVO the purifier space was noted with excessive leaks causing a potential fire hazard. Filter shutdown and repairs to be completed to the satisfaction of class
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 July 2016
Resolution: CLASS REPORT RECEIVED RECTIFYING DEFICIENCY. SEE DOCS
Engineering › Fuel Oil Service System › Pump
Issued 4 May 2016 Resolved
Starboard #2 & Port #1 fuel pumps IWO purifier space noted with excessive leaks that promotes a fire safety hazard. Pumps shut down and repair must be completed to the satisfaction of Class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 July 2016
Resolution: CLASS REPORT RECEIVED, RECTIFYING DEFICIENCY. SEE DOCS
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 4 May 2016 Resolved
The 3-way for the sampline line of the OWS is malfunctioning that emits consistent spray of water when system is activated. System is shut down and repairs to be completed to the satisfaction of Class
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 July 2016
Resolution: CLASS REPORT RECEIVED RECTIFYING DEFICIENCY. SEE DOCS

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.