DMT 141

DMT 141 is a 2004 tank barge. The Coast Guard has recorded 50 inspections since 2004, most recently in June 2021, along with 46 deficiencies — 2 with no resolution recorded — and 3 casualty investigations between 2007 and 2014.

Records from 2004 to 2021. Most recent: inspection, 10 June 2021.

Built
2004
Last inspected
10 June 2021
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the tow units, the recorded names, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 10 June 2021
…with no type recorded15
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 18 calendar years (2004–2021)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9269726
WDB7381
674456
Flag
UNITED STATES
Maury page id
psix-674456

Documentation record

Registered dimensions (L × B × D)487.0 ft × 80.0 ft × 36.5 ft
Registered tonnagegross 9,829 / net 9,829
ITC dimensions (L × B × D)466.1 ft × 80.0 ft × 36.5 ft
ITC tonnagegross 11,089 / net 6,918
BuilderBOLLINGER GRETNA LLC · GRETNA, LA, UNITED STATES · built 2004
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portCHESAPEAKE CITY, MD
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 21 May 2026 · expires 31 May 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it9829 - Regulatory (Subpart C or D), Gross Ton
11089 - Convention (Subpart B), Gross Ton
26280 - Displacement, Gross Ton
9829 - Regulatory (Subpart C or D), Net Ton
6918 - Convention (Subpart B), Net Ton
23585 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

50 inspections, each with its date, unit and type; 46 deficiencies with the resolution recorded against each; 2 vessels inspected with it, by name and date; 1 other recorded name, with years; 3 casualty investigations, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ONYX COAST Towing Vessel · MISLE 674459 · 25 August 2013 · activity 4697946DUPLICATE OF MORTON S. BOUCHARD IV (1154328) Towing Vessel · MISLE 688368 · 30 July 2007 · activity 3020692

Inspection history · 50

10 June 2021 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7221660
17 May 2021 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7199525
30 July 2020 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7020479
24 April 2019 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6669164
10 October 2018 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6558382
10 October 2018 Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6558622
17 August 2018 Administrative Inspection · MARPOL Annex II Examination · MARPOL Annex I Examination · COI Inspection · MTSA Verification · MARPOL Annex VI Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6515187
3 December 2017 In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6317160
31 July 2017 MTSA Verification · Periodic Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6226442
9 May 2017 Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6137341
17 January 2017 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6071838
22 August 2016 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5980156
1 August 2016 MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5955067
1 September 2015 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5232027
25 August 2015 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5216089
12 August 2015 MARPOL Annex VI Survey · MTSA Verification · MARPOL Annex I Examination · MARPOL Annex II Examination · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5212592
29 April 2014 Cargo Tank Internal · COI Inspection · Drydock Exam · Examination of Repairs · Internal Structural Exam · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4846389
5 February 2014 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4795380
28 October 2013 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4742675
25 August 2013 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4697946
2 August 2013 Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4668615
20 March 2012 MTSA Verification · Administrative Inspection · Periodic Inspection · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4268654
19 July 2011 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4087163
14 July 2010 MTSA Verification · MARPOL Annex II Examination · MARPOL Annex VI Survey · MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3791059
24 August 2009 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3575463
12 August 2009 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3563952
6 May 2009 COI Inspection · Administrative Inspection · MTSA Verification · MARPOL Annex VI Survey · Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3474546
12 January 2009 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3393136
31 October 2008 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3354977
23 October 2008 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3352772
2 July 2008 MARPOL Annex I Examination · MTSA Verification · MARPOL Annex V Examination · MARPOL Annex II Examination · Administrative Inspection · Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3254382
26 June 2008 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3248523
30 July 2007 Deficiency Check · Damage Survey · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3011756
30 July 2007 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3020692
4 April 2007 Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2901329
7 February 2007 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2868246
11 August 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2743880
26 July 2006 Annual Inspection · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2725230
17 April 2006 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2626349
15 March 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2603055
3 February 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2578897
14 July 2005 MARPOL Annex I Examination · Annual Inspection · MARPOL Annex II Examination · MARPOL Annex V Examination · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2426192
22 June 2005 MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2408436
14 March 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2309858
14 January 2005 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2276408
5 November 2004 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2235672
4 October 2004 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2213081
19 August 2004 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2175182
28 May 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2080685
5 April 2004 COI Inspection · Initial Certification
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2037595

Deficiency record · 46

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 24 April 2019 No resolution recorded
Barge rep reported that the inert gas system is inoperable. Barge must repair the inert gas system and prove operation prior to carrying or discharging cargoes requiring IG.
Action required: 705 - Other - as specified
14 - Pollution Prevention › 146 - MARPOL Annex VI › Other (MARPOL Annex VI)
Issued 19 October 2018 No resolution recorded
Ships engaged on international voyages with engines over 130kW/175 horsepower installed on vessels constructed on or after January 1, 2000 are required to have a valid EIAPP Certificate issued by the Environmental Protection Agency (EPA). The #1 and #2 SSDG appear to be 175KW and the prime mover should be listed on the vessels IAPP. The vessel was unable to produce a EIAPP certificate for the engines. The Vessel shall not proceed on an international voyage until corrected.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2019 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 October 2018 Resolved
Prove proper operation of the over-speed trip on the #1 SSDG. The over-speed trip failed to shutdown the engine when ships crew opened fuel rack.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 October 2018
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 17 August 2018 Resolved
To maintain a valid Certificate of Inspection, you must complete your annual and periodic inspections with the periods specified in 46CFR31.10-17(a). The Certificate of Inspection on the B. No. 242 has lapsed due to the fourth annual inspection not being completed. The barge shall be in a Gas Free state, determined by a certified Marine Chemist, and a letter from the company shall be sent to Sector New York, stating the location of the barge. Prior to moving the barge, Sector New York shall be notified.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 September 2018
Resolution: Vessel's COI exam was conducted 10SEPT18 and Temp COI was issued.
Deck/Cargo › Inert Gas System › Deck Distribution System
Issued 3 December 2017 Resolved
During operational test of the system, the crew was unable to successfully operate the system. An Inert Gas System technician shall be on board while it is in operation until crew can show competence in operating the system, and also provide a report attesting that the system is operating as intended.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 January 2018
Resolved 10 September 2018
Resolution: Witnessed all shutdowns of IGS with technician.
Lifesaving › Lifebuoys › Serviceable
Issued 3 December 2017 Resolved
he retro reflective tape on the vessels life buoys are deteriorated and ineffective, shall replace in kind.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 December 2017
Resolved 4 December 2017
Resolution: Vessel submitted picuters of newly installed retro reflective tape on life buoys.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 3 December 2017 Resolved
The vapor piping on board the vessel was not grounded to the hull as required by the regulations. The vapor piping must be suitably grounded to the satisfaction of the attending Marine Inspector.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 January 2018
Resolved 10 September 2018
Resolution: Walked the length of the vapor control system.
Deck/Cargo › Mooring/Anchoring › Anchoring Arrangement
Issued 3 December 2017 Resolved
The anchors quick release mechanism is missing (pelican hook).
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 3 December 2017
Resolved 4 December 2017
Resolution: Vessel submitted pictures of newly installed pelican hook on anchor.
Deck/Cargo › Inert Gas System › Scrubber Tower
Issued 22 August 2016 Resolved
Automatic closure valve on IG scrubber is inoperable; (manual valve in line is operational). Isolate valve control from system and repair to original configuration.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 November 2016
Resolved 13 January 2017
Resolution: Closure valve was replaced in kind. Witnessed operation of the unit with no defeciencies.
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 22 August 2016 Resolved
Water heater for deck water seal has broken conduit to power supply. Isolate heater from the electrical system and repair to original configuration.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 November 2016
Resolved 13 January 2017
Resolution: Water heater unit was replaced in kind. Witnessed operation of the unit. Heater brought back in-line with main electrical system.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 1 August 2016 Resolved
Repair or replace toilet exhaust according to manufacturer specs (smoke filling up bathroom - venting next to port hole)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 22 August 2016
Resolution: Exhaust leak ID'd and repaired.
Deck/Cargo › Vapor Control Systems › Vessel Vapor Overpressure/Vacuum Protection
Issued 1 August 2016 Resolved
P/V on mast riser openly venting and no reseating.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 22 August 2016
Resolution: P/V was serviced with operational check complete.
Engineering › Diesel Engine (auxiliary) › Block
Issued 1 August 2016 Resolved
Excessive oil on all prime movers. Wipe down as necessary.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 22 August 2016
Resolution: Prime movers cleaned.
Engineering › Diesel Engine (auxiliary) › Block
Issued 1 August 2016 Resolved
Replace oil lagging on prime movers (Service Generators #1 & #2)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 22 August 2016
Resolution: Lagging on prime movers was found to be clean and serviceable.
Electrical › Electric Generation Source (service) › Ground Detection
Issued 1 August 2016 Resolved
Service Generator #3 ground detection panel lights not functioning.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 22 August 2016
Resolution: Ground detection serviced and functioning properly.
Engineering › Diesel Engine (auxiliary) › Bearing
Issued 1 August 2016 Resolved
Demonstrate low lube oil shutdowns on service generators.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 22 August 2016
Resolution: Low lube shutdowns completed.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 1 August 2016 Resolved
Distribution panel 3phase/120V in service generator space (A,B,C phase lights) inoperable.
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 22 August 2016
Resolution: Phase lights repaired and operational.
Engineering › Pressure Vessel › Marking and Stamping
Issued 1 August 2016 Resolved
Data plate on UPV unreadable. Provide new plate.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 22 August 2016
Resolution: new plate was furnished.
Engineering › Pressure Vessel › Relief Valve
Issued 1 August 2016 Resolved
P/V on UPV could not be demonstrated to properly operate. Demonstrate P/V operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 22 August 2016
Resolution: P/V was checked and operational.
Deck/Cargo › Inert Gas System › IGS Scrubber
Issued 1 August 2016 Resolved
Automated closure valve on water intake line for IG scrubber broken. Repair or replace.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 22 August 2016
Resolution: Closure valve removed from system.
Deck/Cargo › Vapor Control Systems › Vessel Vapor Overpressure/Vacuum Protection
Issued 1 August 2016 Resolved
Demonstrate proper operation of all tank P/V's. All appear to be constantly venting.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 22 August 2016
Resolution: Tank P/Vs checked and operational.
Deck/Cargo › Vapor Control Systems › Vessel Vapor Overpressure/Vacuum Protection
Issued 1 August 2016 Resolved
P/V's not marked with pressure or vacuum settings. Provide documentation attesting to proper settings.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 22 August 2016
Resolution: P/Vs labeled with appropriate setting.
Deck/Cargo › Inert Gas System › IGS Scrubber
Issued 1 August 2016 Resolved
Port side scrubber/ballast pump excessively leaking when in operation. Repair or replace packing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 September 2016
Resolved 22 August 2016
Resolution: Packing replaced to control leakage.
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 1 August 2016 Resolved
Repair exposed wiring on deck water seal sensor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 22 August 2016
Resolution: "Sensor" was found to be deck water heater. Isolated heater from circuit and tagged out system.
Electrical › Electric Generation Source (service) › Generator
Issued 1 August 2016 Resolved
Repair wiring (exposed/loose) as necessary on service generators.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 22 August 2016
Resolution: All exposed wires on service generator replaced or repaired.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 12 August 2015 Resolved
Each generator prime mover must have an overspeed device independent of normal operating governor & must shutdown automatically upon loss of lube oil. Generator tests could not be conducted. Must prove operation to attending CG inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 August 2015
Resolved 14 September 2015
Resolution: Each generator prime mover has an overspeed device independent of normal operating governor & shutdown automatically upon loss of lube oil. Generator tests were conducted satisfactorily to attending CG inspector.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 12 August 2015 Resolved
Machinery capable of injuring personnel shall be provided with adequate guards. #3 house generator guards have detached & is currently zip tied. Must make repairs to satisfaction of CG inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 September 2015
Resolved 14 September 2015
Resolution: Zip ties from #3 house generator guard have been removed and duly fastened.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 12 August 2015 Resolved
Vessel has inert gas system onboard barge; cannot test system. Must prove operations of alarms to attending CG inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 August 2015
Resolved 14 September 2015
Resolution: Vessel inert gas system has been properly operated and tests conducted satisfactorily to attending CG inspector.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 19 May 2014 Resolved
Ensure life ring lines (both rings) are in serviceable condition IAW 46 CFR 199.70.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 May 2014
Resolved 22 May 2014
Resolution: Verified replacement of deteriorated grab lines.
Engineering › Generator (propulsion-electric) › Overcurrent Devices Circuitry
Issued 19 May 2014 Resolved
Ensure #2 generator is fully operational IAW 46 CFR 111.12-1.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 May 2014
Resolved 22 May 2014
Resolution: Completed over speed, low lube oil, & high water temp. test, all SAT.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 19 May 2014 Resolved
Ensure high level alarm visual indicator is working properly IAW 46 CFR 39.20-7(d).
Action required: 705 - Other - as specified
Due 21 May 2014
Resolved 22 May 2014
Resolution: Tested operation of 1-8 P&S cargo tank high level alarms.
Operations/Management › Ballast Water Managment › Ballast Water Discharge
Issued 19 May 2014 Resolved
Ensure P6 ballast valve open/close indicator is functioning properly IAW 46 CFR 56.20-9.
Action required: 705 - Other - as specified
Due 21 May 2014
Resolved 22 May 2014
Resolution: Verified proper functioning of the valve.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 29 July 2013 Resolved
Renew 1, 2, 3, ballast (for both Port and Stbd side) scuttles at next Dry Dock Exam.
Action required: 705 - Other - as specified
Due 6 May 2014
Resolved 19 May 2014
Resolution: A total of 12 ballast scuttles were cropped and renewed during May 2014 drydock period.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 July 2013 Resolved
Replace forward anchor light.
Action required: 705 - Other - as specified
Due 16 August 2013
Resolved 6 August 2013
Engineering › Diesel Engine (propulsion-electric) › Seal
Issued 29 July 2013 Resolved
Cargo pump engines & Generator engines all have excessive oil leaks; repair/replace defective gaskets, seals, or other components for leaking issues.
Action required: 705 - Other - as specified
Due 2 November 2013
Resolved 28 October 2013
Resolution: Rcvd third party tech report attesting to the replacement of gaskets for generators.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 29 July 2013 Resolved
Provide proof/testing cert of cargo piping gauges.
Action required: 705 - Other - as specified
Due 16 August 2013
Resolved 2 August 2013
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 29 July 2013 Resolved
reapir or replacedefective pin on CO2 Extinguisher for forward most paint locker.
Action required: 705 - Other - as specified
Due 16 August 2013
Resolved 2 August 2013
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Overspeed Device
Issued 29 July 2013 Resolved
Demonstrate satisfactory operation of generator and main engine overspeed & lube oil shutdowns.
Action required: 705 - Other - as specified
Due 2 November 2013
Resolved 28 October 2013
Resolution: Rcvd third party tech report attesting to the successful testing of the Genset''s over speed and lube oil shutdowns.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 29 July 2013 Resolved
Demonstrate satisfactory operation of all alarms and shutdowns for IG system.
Action required: 705 - Other - as specified
Due 2 November 2013
Resolved 28 October 2013
Resolution: Rcvd third party tech report attesting to maintenance and testing of IG system and all alarms.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 19 July 2011 Resolved
Vessel does not have bunkering drip sample station at bunkering fuel tank inlet.
Action required: 705 - Other - as specified
Due 20 August 2011
Resolved 25 July 2011
Resolution: Vessel provided proof of installation of drip sample valve.
Engineering › Generator (propulsion/auxiliary-electric) › Auto Transformer Circuitry
Issued 14 May 2009 Resolved
Conduct overspeed tests of # 1 & 2 generators utilizing an accurate method i.e. hand held tachometer timing gun etc.
Action required: 705 - Other - as specified
Due 13 June 2009
Resolved 11 June 2009
Resolution: Received technician report from company attesting that overspeed tests on both gensets were conducted utilizing a handheld tachometer. This satisfies 835 requirement.
Documentation › Certificates/Documents › Engine IAPP Certificate
Issued 6 May 2009 Resolved
Provide Certificate, voyage limited to Domestic until EIAPP is provided.
Action required: 705 - Other - as specified
Resolved 14 July 2010
Resolution: Vessel provided valid EIAPP certificates. Conducted IAPP survey, sat.
Construction/Loadline › Hull › Hull Plating
Issued 30 July 2007 Resolved
Prior to moving the vessel, submit dive survey, and salvage/float plan (temp repairs) for the safe movement from Albany, NY to Staten Island, NY where the vessel is to be made gas free and permanent repairs made to the satisfaction of attending Coast Guard Marine inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 July 2007
Resolution: Vsl submitted dive survey, permitted to transfer vsl to Staten Island, NY for gas freeing and drydocking.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 14 July 2005 Resolved
Provide span/0% calibration gas to check gas analyzer to the IGS and conduct checks IAW manufacturers instruction. SOLAS CH II-2 Reg. 62/18
Due 28 July 2005
Resolved 22 July 2005
Resolution: Received conformation that the required apparatus was received onboard.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Communications
Issued 14 July 2005 Resolved
MSO providence identified a communication shortfall at the manifold due to machinery noise on 05NOV04. Vessel still has not addressed problem. Provided improved communications to the manifold.
Due 3 August 2005
Resolved 22 August 2005
Resolution: Received conformation that the vessel has adopted the use of specialized radio equipment to mitigate the machinery noise.
Lifesaving › Inflatable Liferafts
Issued 5 April 2004 Resolved
Liferafts must be stowed in accordance with 46CFR199.130. Specifically, liferafts must be stowed to permit manual release from its securing arrangements, drop into the water from the deck on which it is stowed and is on a platform adjacent to the rail or bulwark. Centerline liferafts are unaccep.
Action required: 705 - Other - as specified
Resolved 28 April 2004
Resolution: Marine inspector witnessed deployment test. Total time took 1minute 9 seconds for port life float and accom ladder.

Casualty record · 3

30 July 2007Routine · role: Involved in a Marine Casualty · activity 3020692
25 August 2013Routine · role: Involved in a Marine Casualty · activity 4697946
5 February 2014Routine · role: Acknowledged Pollution Source · activity 4795380
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

B. NO. 242 (2007–2014). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.