MAURY USCG vessel records Sign in
← All vessels

WEST BAY

WEST BAY is a 2004 freight ship. The Coast Guard has recorded 33 inspections since 2004, most recently in April 2025, along with 8 deficiencies and 3 operational controls.

Records from 2004 to 2025. Most recent: inspection, 10 April 2025.

Built
2004
Last inspected
10 April 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9278868 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
674679
Flag
HONG KONG
—
Maury page id
psix-674679

Inspections, by type

…with no type recorded10
Years with a record 14 calendar years (2004–2025)
The 33 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it30124 - Convention (Subpart B), Gross Ton
17738 - Convention (Subpart B), Net Ton
60772 - Displacement, Metric Ton
52451 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MICHAEL BRANDON Commercial Fishing Vessel · MISLE 189445 · 11 January 2011 · activity 3925222

Inspection history · 33

10 April 2025 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8109514
10 April 2025 COE-Administrative
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8109727
22 March 2025 COE-Administrative · Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8097881
18 June 2024 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7937493
5 April 2024 PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7890054
28 March 2024 Deficiency Check · Administrative Inspection · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7886255
25 April 2023 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7675334
12 April 2023 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7663079
24 August 2021 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7295030
26 April 2020 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6944053
24 February 2020 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6914957
2 September 2018 NPV Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6522319
25 August 2017 ISPS II Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6251280
3 August 2017 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6229575
10 December 2015 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 5778921
3 November 2015 Administrative Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5756181
27 October 2015 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5748782
11 January 2011 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3925157
11 January 2011 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3925222
7 January 2011 ISPS II Exam · PII Safety Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3919345
6 January 2011 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3920345
10 April 2008 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3180642
19 March 2007 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2890348
14 April 2006 MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination · MARPOL Annex V Examination · PII Safety Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2621079
24 March 2006 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2609003
16 September 2005 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2494051
15 June 2005 Random ISPS/MTSA/PSC
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2391295
9 April 2005 Ballast Water Examination · PII Safety Exam · ISPS III Exam · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2326353
24 March 2005 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2319347
12 February 2005 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2291243
22 September 2004 ISPS II Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2201889
8 April 2004 Annual Inspection · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2037048
7 April 2004 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2253045

Deficiency record · 8

03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 5 April 2024 Resolved
03104 - Water/Weathertight conditions - the arrangements shall ensure that the tightness can be maintained in any sea conditions. PSCO observed hydraulic fluid leaking from cargo hatch #4 control valves, amounting to about 1 gallon of hydraulic fluid in the catch pan. ILLC Annex 1 Reg 16(4) 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 April 2024
Resolution: Received NKK class report #24NY0139 detailing rectification
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 5 April 2024 Resolved
11101 - Lifeboats - before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed leaking engine coolant line on #1 lifeboat during engine operational test. 74 SOLAS (20) III/20.2 10c
Action required: 10 - Deficiency Rectified
Resolved 5 April 2024
Resolution: Crew replaced fualty O-ring in colant line and attached new hose clamp.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 28 March 2024 Resolved
ALL THE STEERING GEAR COMPONENTS AND THE RUDDER STOCK SHALL BE OF SOUND AND RELIABLE CONSTRUCTION TO THE SATISFACTION OF THE ADMINISTRATION. PSCO OBSERVED STARBOARD HYDRAULIC RAM FOR THE STEERING LEAKING HYDRAULIC OIL WHILE IN OPERATION AND AFTER THE SYSTEM WAS SHUT DOWN. 74 SOLAS (04) II-1/29.2.1 CODE 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 March 2024
Resolved 1 April 2024
Resolution: Recieved class report attaesting to installation of new seal on steering gear. No leaks observed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 March 2024 Resolved
FOR ANY VESSEL THAT IS EQUIPPED WITH BALLAST WATER TANKS AND BOUND FOR PORTS OR PLACES IN THE UNITED STATES: SUBMIT THE BALLAST WATER REPORT NO LATER THAN 6 HOURS AFTER ARRIVAL AT THE PORT OR PLACE OF DESTINATION, OR PRIOR TO DEPARTURE FROM THAT PORT OR PLACE OF DESTINATION, WHICHEVER IS EARLIER. PSCO OBSERVED THAT NO BALLAST WATER REPORT WAS SUBMITTED WITHIN THE REQUIRED DEADLINE. 33 CFR 151.2060(b)(3) 15C
Condition: Invalid
Action required: 15 - Rectify deficiencies by next port
Due 5 April 2024
Resolved 5 April 2024
Resolution: Vessel submitted ballast water report in Sector St Petersburg AOR.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 27 October 2015 Resolved
1730- Oil filtering equipment reffered to in paragraph 2 of this regulation shall comply with paragraph 6 of this regulation. The MEPC 60 (33) OWS and OCM are currently unable to process bilge water from the holding tank to less than 15 ppm....See narrative for complete deficiency.
Action required: 15 - Rectify deficiencies by next port
Resolved 3 November 2015
Resolution: See attached class report The above deficiency has been dealt with by: The crew cleaned the piping in the vicinity of the OWS sensor. OWS operational test was carried out with positive results.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 27 October 2015 Resolved
0715- Heat detection systems shall be tested by means of suitable heat producing equipment. Crew on board were using lighters to test heat detectors in engine room. SOLAS 74 (2014) II-2/ 7.3.2 Action Taken 15ac
Action required: 15 - Rectify deficiencies by next port
Resolved 3 November 2015
Resolution: See attached class report The above deficiency has been dealt with by: The vessel ordered a heat detector tester and it was delivered to the vessel.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 27 October 2015 Resolved
0750- The fire integrity of the divisions shall be maintained at openings and penetrations. Bulkhead in the engine room was found missing insulation at the wiring opening. Missing insulation compromises the integrity of the A-60 bulkhead for the steering gear room. SOLAS 74(2014)II-2/9.1.3 Action taken 15ac
Action required: 15 - Rectify deficiencies by next port
Resolved 3 November 2015
Resolution: The above deficiency has been dealt with by: The crew reapplied fire stop on the forward and after ends of the cable transit
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 27 October 2015 Resolved
0950- Accumulator batteries shall be suitably housed, and compartments used primarily for their accomodation. 12 accumulator batteries were inproperly stored on deck in the emergency generator room. SOLAS 74 (2004)II-1/45.9.1 Action taken 15ac
Action required: 15 - Rectify deficiencies by next port
Resolved 3 November 2015
Resolution: The above deficiency has been dealt with by: The vessel installed a battery storage compartment in the emergency generator room.

Ownership record