Records from 2004 to 2025. Most recent: inspection, 10 April 2025.
Inspection history · 33
10 April 2025
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8109514
10 April 2025
COE-Administrative
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8109727
22 March 2025
COE-Administrative · Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8097881
18 June 2024
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7937493
5 April 2024
PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7890054
28 March 2024
Deficiency Check · Administrative Inspection · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7886255
25 April 2023
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7675334
12 April 2023
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7663079
24 August 2021
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7295030
26 April 2020
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6944053
24 February 2020
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6914957
2 September 2018
NPV Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6522319
25 August 2017
ISPS II Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6251280
3 August 2017
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6229575
10 December 2015
Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 5778921
3 November 2015
Administrative Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5756181
27 October 2015
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5748782
11 January 2011
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3925157
11 January 2011
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3925222
7 January 2011
ISPS II Exam · PII Safety Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3919345
6 January 2011
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3920345
10 April 2008
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3180642
19 March 2007
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2890348
14 April 2006
MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination · MARPOL Annex V Examination · PII Safety Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2621079
24 March 2006
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2609003
16 September 2005
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2494051
15 June 2005
Random ISPS/MTSA/PSC
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2391295
9 April 2005
Ballast Water Examination · PII Safety Exam · ISPS III Exam · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2326353
24 March 2005
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2319347
12 February 2005
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2291243
22 September 2004
ISPS II Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2201889
8 April 2004
Annual Inspection · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2037048
7 April 2004
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2253045
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 5 April 2024
Resolved
03104 - Water/Weathertight conditions - the arrangements shall ensure that the tightness can be maintained in any sea conditions. PSCO observed hydraulic fluid leaking from cargo hatch #4 control valves, amounting to about 1 gallon of hydraulic fluid in the catch pan.
ILLC Annex 1 Reg 16(4) 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 April 2024
Resolution: Received NKK class report #24NY0139 detailing rectification
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 5 April 2024
Resolved
11101 - Lifeboats - before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed leaking engine coolant line on #1 lifeboat during engine operational test.
74 SOLAS (20) III/20.2 10c
Action required: 10 - Deficiency Rectified
Resolved 5 April 2024
Resolution: Crew replaced fualty O-ring in colant line and attached new hose clamp.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 28 March 2024
Resolved
ALL THE STEERING GEAR COMPONENTS AND THE RUDDER STOCK SHALL BE OF SOUND AND RELIABLE CONSTRUCTION TO THE SATISFACTION OF THE ADMINISTRATION.
PSCO OBSERVED STARBOARD HYDRAULIC RAM FOR THE STEERING LEAKING HYDRAULIC OIL WHILE IN OPERATION AND AFTER THE SYSTEM WAS SHUT DOWN.
74 SOLAS (04) II-1/29.2.1 CODE 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 March 2024
Resolved 1 April 2024
Resolution: Recieved class report attaesting to installation of new seal on steering gear. No leaks observed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 March 2024
Resolved
FOR ANY VESSEL THAT IS EQUIPPED WITH BALLAST WATER TANKS AND BOUND FOR PORTS OR PLACES IN THE UNITED STATES: SUBMIT THE BALLAST WATER REPORT NO LATER THAN 6 HOURS AFTER ARRIVAL AT THE PORT OR PLACE OF DESTINATION, OR PRIOR TO DEPARTURE FROM THAT PORT OR PLACE OF DESTINATION, WHICHEVER IS EARLIER.
PSCO OBSERVED THAT NO BALLAST WATER REPORT WAS SUBMITTED WITHIN THE REQUIRED DEADLINE.
33 CFR 151.2060(b)(3) 15C
Condition: Invalid
Action required: 15 - Rectify deficiencies by next port
Due 5 April 2024
Resolved 5 April 2024
Resolution: Vessel submitted ballast water report in Sector St Petersburg AOR.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 27 October 2015
Resolved
1730- Oil filtering equipment reffered to in paragraph 2 of this regulation shall comply with paragraph 6 of this regulation. The MEPC 60 (33) OWS and OCM are currently unable to process bilge water from the holding tank to less than 15 ppm....See narrative for complete deficiency.
Action required: 15 - Rectify deficiencies by next port
Resolved 3 November 2015
Resolution: See attached class report
The above deficiency has been dealt with by: The crew cleaned the piping in the vicinity of the
OWS sensor. OWS operational test was carried out with positive results.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 27 October 2015
Resolved
0715- Heat detection systems shall be tested by means of suitable heat producing equipment. Crew on board were using lighters to test heat detectors in engine room. SOLAS 74 (2014) II-2/ 7.3.2 Action Taken 15ac
Action required: 15 - Rectify deficiencies by next port
Resolved 3 November 2015
Resolution: See attached class report
The above deficiency has been dealt with by: The vessel ordered a heat detector tester and it was delivered to the vessel.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 27 October 2015
Resolved
0750- The fire integrity of the divisions shall be maintained at openings and penetrations. Bulkhead in the engine room was found missing insulation at the wiring opening. Missing insulation compromises the integrity of the A-60 bulkhead for the steering gear room.
SOLAS 74(2014)II-2/9.1.3 Action taken 15ac
Action required: 15 - Rectify deficiencies by next port
Resolved 3 November 2015
Resolution: The above deficiency has been dealt with by: The crew reapplied fire stop on the forward and
after ends of the cable transit
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 27 October 2015
Resolved
0950- Accumulator batteries shall be suitably housed, and compartments used primarily for their accomodation. 12 accumulator batteries were inproperly stored on deck in the emergency generator room. SOLAS 74 (2004)II-1/45.9.1 Action taken 15ac
Action required: 15 - Rectify deficiencies by next port
Resolved 3 November 2015
Resolution: The above deficiency has been dealt with by: The vessel installed a battery storage compartment in the emergency generator room.