Records from 2016 to 2024. Most recent: inspection, 9 April 2024.
Inspection history · 6
9 April 2024
COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7887517
21 May 2019
Ballast Water Examination · ISPS III Exam · COC-CHEM & TVE Annual
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6686252
9 July 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6472684
4 July 2018
Ballast Water Examination · COC-CHEM & TVE Renew · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6459544
23 August 2017
COC-CHEM & TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6248055
22 May 2016
ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5883353
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 4 July 2018
Resolved
9900- (Other Clearly Hazardous)The condition of the ship and its equipment shall be mainted to confirm with the provisions of the present regulations to ensure the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed hydraulic oil leaking from solenoid valves #1P, #2p, #4s, #3 main and #2 main of framo cargo pumps. Active Leaking has resulted in coating the valves, pipe lines, and deck area of fire protection room with hydraulic oil presenting a fire hazard. SOLAS 74(a) 2014 Cons. I/11 action taken 50.a.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 August 2018
Resolved 7 July 2018
Resolution: PSC NOLA received a class report from DNV-GL satisfying the requirement.
Lifesaving › Lifeboat › Embarkation/Disembarkation Capabilities
Issued 23 August 2017
Resolved
0610 - Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. The starboard side lifeboat was lowered and could not be properly cradled and returned to the stowed position. 74SOLAS(14)III/20.2 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 August 2017
Resolved 23 August 2017
Resolution: Received Class [name withheld] attesting to the proper operation of the falls.
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 23 August 2017
Resolved
0950 - After any survey of the ship has been completed, no change shall be made in the items covered by the survey without the sanction of the Administration. An air conditioning unit was rigged on the portside birdge wing. The condition of the wiring poses an electrical hazard. 74SOLAS(14)I/11(b) 50AC
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 September 2017
Resolved 23 August 2017
Resolution: Received Class [name withheld] attesting to wiring of the air conditioner.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 23 August 2017
Resolved
0950 - Cables and wiring shall be installed and supported in such a manner as to avoid chafing or other damage. The air conditioning unit installed on the portside bridge wing had wiring that was not suficiently supported. 50AC
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 September 2017
Resolved 23 August 2017
Resolution: Received Class [name withheld] attesting to proper installment of the air conditioner.
Fire Fighting › Structural - Main Vertical Zones › General
Issued 23 August 2017
Resolved
0710 - Protection of openings in fire protection divisions shall be kept in good order to ensure their performance. Fire door 3F B-Deck would not close properly. 74SOLAS(14)II-2/41.2.1.1.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 September 2017
Resolved 23 August 2017
Resolution: Vessel's crew repaired closure device on door and demonstrated proper operation to the satisfaction of attending Coast Guard inspectors.
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 23 August 2017
Resolved
1820 - The alarms required in paragraphs 19.1.5, 19.1.6 and 19.1.8 shall be fitted in the machinery space and cargo control room as provided. No audible alarms for IGS would sound in the cargo control room. 74SOLAS(01)II-2/62.19.6 50AC
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 September 2017
Resolved 23 August 2017
Resolution: The IGS is approved in accordance with the requirements of the Classification Rules, SOLAS Ch. II-2, Reg 4.5.5 and the FSS Code. This is also confirmed with the IGS approval documentation onboard.