Records from 2016 to 2026. Most recent: inspection, 4 March 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 25
4 March 2026
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8319733
16 September 2025
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8235309
6 February 2025
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8075623
18 December 2024
Type not recorded
No type recorded · USCGC STINGRAY (WPB 87305) · USCG Heartland District (CGD-H) · Activity 8050329
3 January 2024
Drydock Exam · Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7844915
1 December 2023
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7833110
9 March 2023
Plan Review "T" Boat · Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7648486
24 October 2022
COI Inspection · Re-Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7578926
24 May 2022
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7458071
21 March 2022
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7431334
18 January 2022
Hull Examination · Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7381843
25 June 2021
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7270961
22 March 2021
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7162177
24 July 2020
Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7014958
14 February 2020
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6909105
22 January 2020
Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6897279
15 January 2020
Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6890176
6 March 2019
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6637290
7 February 2018
DAPI Audit · Administrative Inspection · Annual Inspection · Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6351316
24 April 2017
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6131836
3 March 2017
DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6098696
7 April 2016
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5849827
16 March 2016
Annual Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5835372
29 February 2016
Administrative Inspection · Simplified Stability Test
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5823790
29 January 2016
Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5807335
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 12 March 2026
Resolved
Vessel is required to have 1 life ring buoy of not less than 24 inches in diameter. This life ring buoy must be approved in accordance with 46 CFR 160.050. Vessel's life ring buoy was serviceable due to deterioration.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2026
Resolution: recieved picture evidence of rectification
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 12 March 2026
Resolved
Vessel's IBAs were not installed correctly. Painter line was not connected. Install and appropriately connect Painter Line
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2026
Resolution: recieved picture evidence of rectification
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 12 March 2026
Resolved
Vessel's hydrostatic release units for IBAs were expired. Hydrostatic release units must meet 46 CFR 160.062 or 46 CFR 160.162. Replace as appropriate.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2026
Resolution: recieved picture evidence of rectification
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 12 March 2026
Resolved
Vessel is required to have 6 day and 6 night visual distress signals meeting 46 CFR 160.021 (day) or 46 CFR 160.037 (day only) or 46 CFR 160.036 (day/night). Vessel did not have the appropriate number and type(s) of flares on-board. Ensure 12 total flares are present and of the appropriate type(s) are on the vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2026
Resolution: recieved picture evidence of rectification
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 12 March 2026
Resolved
Step down into tank room is beginning to de-laminate from the bulkhead. Repair or replace as appropriate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2026
Resolved 17 March 2026
Resolution: recieved picture evidence of rectification
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 5 March 2025
Resolved
Each launching appliance and each survival craft and rescue boat on a vessel must be in good working order and ready for immediate use before the vessel leaves port and at all times when the vessel is underway. Painter lines for both liferafts were disconnected from the weak links.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2025
Resolution: Received photos from operator detailing reconnected painter lines IAW manufacturer.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 5 March 2025
Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. More than 24 months has elapsed since the installation of the EPIRB hydrostatic release unit.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2025
Resolution: Received photos from operator detailing renewed hydrostatic release.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 30 January 2024
Resolved
Each vessel certified to operate on an oceans route in warm water must be provided with and inflatable buoy and apparatus of aggregate capacity to accommodate 67% of total persons permitted on board. Vessels IBA were off vessel to be serviced. Provide servicing report and proof of reinstalled IBA to include current hydrostatic releases. Vessel is restricted to not more than 3NM offshore.
46 CFR 180.202
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 February 2024
Resolved 16 February 2024
Resolution: Received photographic documentation for the life raft servicing, hydro and installation. Sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 January 2024
Resolved
An adult life jacket must be provided for each person carried on board a vessel and must be approved in accordance with either 160.002 -.005 or -.055 in sub-chapter Q. 10 of the vessels life jackets have deteriorated Solas retro-reflective material. Renew retro-reflective tape.
46 CFR 180.71
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 February 2024
Resolved 28 February 2024
Resolution: Attended vessel and observed renewed retro reflective tape on 10 life jackets.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 January 2024
Resolved
Each fire extinguisher on a vessel must be of an approved type and must me acceptable to the cognizant OCMI. 01 of the vessels fire extinguishers indicated in the red on the pressure gauge. Fire extinguisher is in excess of the required amount therefore either remove the extinguisher or have it serviced and replace on board.
46 CFR 180.500
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2024
Resolved 16 February 2024
Resolution: Received photographic documentation for the servicing of the fire extinguishers. Sat.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 30 January 2024
Resolved
Interconnected smoke detection and alarm system must be installed such that the actuation of alarm in one area results in both audible and visual alarms in all areas. System only alarmed on the bridge of the vessel. Make all stations operable. Additionally roving deckhand required on all trips. No overnight trips authorized until rectified.
46 CFR 181.405
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 February 2024
Resolved 28 February 2024
Resolution: Attended vessel and crew tested interconnected smoke alarms.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 30 January 2024
Resolved
A vessel on a oceans route must carry 6 hand red flares distress signals and 6 orange smoke distress signals. 6 signals were out of date. Route restricted to lakes, bays and sounds and rivers.
46 CFR 181.68
Action required: 705 - Other - as specified
Due 13 February 2024
Resolved 16 February 2024
Resolution: Received photographic documentation for the flares, Sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 January 2024
Resolved
Vessels of more than 7.9 meters shall have an operable floating water light. Water light battery was expired, renew battery. Restricted to daylight only operations.
46 CFR 180.70
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 February 2024
Resolved 16 February 2024
Resolution: Received photographic documentation for the in date approved battery lights, Sat.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 30 January 2024
Resolved
A appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts, U.S. Coast Pilot, Coast Guard light list and tide and current tables. Vessels charts and pubs are outdated. Provide up-to-date charts and pubs for vessels operating area.
46 CFR 184.420
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2024
Resolved 28 February 2024
Resolution: Attended vessel. Crew showed proof of updated charts and pubs. Marine Inspector found sat.
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 30 January 2024
Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels. Vessel could not provide satisfactory proof of random drug test program for all crewmembers.
46 CFR 16.230
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2024
Resolved 24 April 2024
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 30 January 2024
Resolved
Employee assistance programs must be conducted for the employer's crewmembers and supervisory personnel. Supervisory personnel must receive at least 60 minutes of training. Supervisor does not have a certificate of completion. Show completed course documentation.
46 CFR 16.401
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2024
Resolved 1 April 2024
Resolution: Received satisfactory objective evidence of supervisory training.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 January 2024
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection. Generator is missing machinery guard. Re-install machinery guard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2024
Resolved 16 February 2024
Resolution: Received photographic documentation for the reinstallaion of the machinery guards. Sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 3 January 2024
Resolved
Each watertight bulkhead must be of sufficient strength to be capable of remaining watertight with a head of water to the top of the bulkhead. Wires in the tank room to engine room have missing caulking. Renew caulking.
46 CFR 179.320
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2024
Resolved 16 February 2024
Resolution: Received photographic documentation for the corrected bulkhead penatration, Sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 October 2022
Resolved
A vessel must be provided with bilge pumps in accordance with 46 CFR Table 182.520(a). Submersible electric bilge pump in engine room was inoperable. Repair or replace and provide proof of operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 November 2022
Resolved 3 November 2022
Resolution: Received video of operational bilge pump and bilge alarm.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 26 October 2022
Resolved
A vessel with more than one passenger deck and overnight accommodation must have the public address system operable from the operating station. Aft stbd speaker was inoperable and hindered PA capabilities. Repair or replace and provide proof of operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 November 2022
Resolved 3 November 2022
Resolution: Received video of operational aft speaker.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 29 March 2021
Resolved
Radiotelephony certificate is expired, renew certificate.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 29 April 2021
Resolved 9 April 2021
Resolution: Receive Documentary evidence of Safety Radiotelephony Cert.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 March 2021
Resolved
Life buoy battery is expired, replace battery.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 12 April 2021
Resolved 1 April 2021
Resolution: Documentary evidence sent with picture of the newly purchased life buoy battery.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 29 March 2021
Resolved
Alcohol test swabs expired, replace swabs.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 April 2021
Resolved 19 April 2021
Resolution: Received documentary evidence of alcohol swabs repalced with new, experation daty 30APR22
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 March 2020
Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46CFR164.018 and approved lights.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 10 March 2020
Resolution: Life jackets noted were relabeled with approved SOLAS retroreflective tape and lights as needed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 March 2020
Resolved
Each ring life buoy must be marked in clearly legible block capital letters with vessels name and be marked with Type II retroreflective material approved in 46CFR164.018.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2020
Resolved 10 March 2020
Resolution: Life Ring relabeled with approved SOLAS tape and required markings
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 9 March 2020
Resolved
A Vessel must carry adequate and up to date charts to make safe navigation possible.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2020
Resolved 20 April 2020
Resolution: Vessel purchased new charts.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 9 March 2020
Resolved
Each watertight bulkhead must be of sufficient strength to be capable of remaining watertight with a head of water to the top of the bulkhead. Make through-holes watertight located in stbd aft corner of tank void to lazarette void.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2020
Resolved 10 March 2020
Resolution: Through holes filled, made watertight, all satisfactory
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 January 2020
Resolved
Vessel owner informed the CG that he replaced the engines, shafts and props. Owner was issued an 835 and was informed that he can not operate with passengers until sea trials along with DVTP's could be performed on the vessel.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 January 2020
Resolved 3 March 2020
Resolution: Conducted successful sea trials and DVTPs on the M/V ENTERTAINER.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 5 March 2018
Resolved
System had a fault on the installed fire detection system
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 March 2018
Resolved 8 March 2018
Resolution: batteries for the control panel had to be replaced. Vessel also had a technician come to check entire system.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 5 March 2018
Resolved
only zones would show up on the control panel when a space would alarm. However there was no way to identify which zone went to which space. Update location on the display so that space correspondes with zones.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 March 2018
Resolved 8 March 2018
Resolution: Vessel had technician come out and reassign the proper space on vessel to zone and alarm.
Communications › Audible Communications › Horn/Whistle
Issued 5 March 2018
Resolved
Vessel's horn is inoperable
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 March 2018
Resolved 5 March 2018
Resolution: Vessel corrected def on the spot, fixed a loose wire
Electrical › Lighting (emergency) › Lighting Fixture
Issued 5 March 2018
Resolved
Emergency lighting at the bottom of berthing stairs was inoperable.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 March 2018
Resolved 8 March 2018
Resolution: Replaced light fixture
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 5 March 2018
Resolved
Vessel did not have a copy of navigational rules on board.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 April 2018
Resolved 8 March 2018
Resolution: Inspector saw vessel had obtained a copy of navigational rules.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 5 March 2018
Resolved
EPIRB has not been tested monthly
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 April 2018
Resolved 8 March 2018
Resolution: Inspector verified CAPT was logging EPIRB test, also questioned the CAPT again on when he is required to test and where it should be logged.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 5 March 2018
Resolved
CAPT could not show proof of his supervisory DAPI training
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 April 2018
Resolved 8 March 2018
Resolution: CAPT showed proof of DAPI certificate, 60 minutes of training.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 30 March 2017
Resolved
Provide documentation that drug and alcohol background checks are being completed. 49 CFR 40.25
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 April 2017
Resolved 24 April 2017
Resolution: Documentation provided.
Communications › Radio Communications › EPIRB
Issued 30 March 2017
Resolved
Conduct monthly EPIRB operational test. 46 CFR 185.728
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 April 2017
Resolved 30 March 2017
Resolution: Master conducted satisfactory EPIRB test during inspection, completed required documentation and was informed of the requirement to conduct and maintain monthly testing records.
Navigation › Piloting/Steering › Marine Charts
Issued 30 March 2017
Resolved
Provide updated charts for the areas where the vessel operates. 46 CFR 184.410/420
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 April 2017
Resolved 24 April 2017
Resolution: New charts purchased.
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 30 March 2017
Resolved
Provide battery operated smoke detector in fwd compartment and replace with permanent at next servicing. 46 CFR 177.410(c)(3)
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 April 2017
Resolved 24 April 2017
Resolution: Smoke detector purchased and mounted.
Documentation › Logs/Records › Logbook (official)
Issued 30 March 2017
Resolved
Provide documentation that the fire, man overboard, and abandon ship drills are being conducted quarterly. 46 CFR 185.520
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 March 2017
Resolved 30 March 2017
Documentation › Markings/Placards › Warning Signs
Issued 30 March 2017
Resolved
Provide appropriate breaker and signage derating generator to 80% of rated amperage. 46 CFR 183.320.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 April 2017
Resolved 24 April 2017
Resolution: Rating derated placard posted.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 30 March 2017
Resolved
Provide ground wire on fuel fill. 46 CFR 182.445
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 April 2017
Resolved 24 April 2017
Resolution: Ground wire installed.
Documentation › Certificates/Documents › Stability Letter
Issued 30 March 2017
Resolved
Post emergency instructions and stability letter at operating station. 46 CFR 185.510
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 April 2017
Resolved 24 April 2017
Resolution: Instructions posted.
Communications › Radio Communications › VHF Radiotelephone
Issued 30 March 2017
Resolved
Have FCC rep program all radios with MMSI number and connect GPS to radios. 47 CFR 80
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 April 2017
Resolved 24 April 2017
Resolution: Radio MMIS number on radio, registered.
Communications › Radio Communications › VHF Radiotelephone
Issued 30 March 2017
Resolved
Post SSB frequencies next to radios to be used in emergencies. 46 CFR 176.800
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 April 2017
Resolved 24 April 2017
Resolution: Frequency channels posted.
Engineering › Pressure Vessel › Relief Valve
Issued 16 March 2016
Resolved
Vessel's hot water tank has a pressure relief device with a set pressure of 150 psi. Replace device with one set at no more than 100 psi. IAW 46 CFR 182.320.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 March 2016
Resolved 7 April 2016
Resolution: Installed 100 psi relief valve.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 16 March 2016
Resolved
Vessels alcohol testing devices were expired. Obtain new, non-expired, approved alcohol testing devices. IAW 46 CFR 185.212 and 46 CFR 4.06-15.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2016
Resolved 7 April 2016
Resolution: Provided new, valid alcohol testing devices.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 16 March 2016
Resolved
Vessel has a freezer kept in the accommodation space. Secure freezer from shifting/movement. IAW 46 CFR 176.830
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 March 2016
Resolved 7 April 2016
Resolution: Freezer secured with brackets mounted on deck.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 March 2016
Resolved
Vessel has a cut/dead end wire in a fwd compartment. Remove wire or properly cap and enclose it. IAW 46 CFR 183.200.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2016
Resolved 7 April 2016
Resolution: Removed unused wires.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 16 March 2016
Resolved
Vessel has two electrical outlets near its "galley" sink without drip proof covers. Install drip proof covers on outlets. IAW 46 CFR 183.210.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2016
Resolved 7 April 2016
Resolution: Installed outlet covers.
Fire Fighting › Structural - B Class Divisions › Main Galleys
Issued 16 March 2016
Resolved
Vessel has a portable deep-fat fryer on board, without B-15 class fire boundaries. Either remove fryer or install B-15 class fire boundaries. IAW 46 CFR 177.410.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 March 2016
Resolved 7 April 2016
Resolution: Removed deep-fat fryer from vessel.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 16 March 2016
Resolved
Vessel has plastic waste receptacles on board. Remove and/or replace with non-combustable type waste receptacles. IAW 46 CFR 177.405.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 March 2016
Resolved 7 April 2016
Resolution: Purchased metal liner to place inside plastic/rubber trashcan for fantail. Removed receptacle from "galley".
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 16 March 2016
Resolved
Vessel had life jacket stowage in the forward "V" berthing area. Ensure life jacket stowage is marked/labeled. IAW 46 CFR 180.78 and 46 CFR 185.604.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 March 2016
Resolved 7 April 2016
Resolution: Lifejacket stowage properly labeled.