MAURY USCG vessel records
← All vessels

CHLOE D

CHLOE D is a 2002 freight ship. The Coast Guard has recorded 8 inspections since 2024, most recently in December 2025, along with 5 deficiencies and 1 operational control.

Records from 2024 to 2025. Most recent: inspection, 15 December 2025.

Built
2002
Last inspected
15 December 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 December 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 2 calendar years (2024–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9241190
675057
Flag
LIBERIA
Maury page id
psix-675057

Documentation record

Tonnage as PSIX records it27779 - Convention (Subpart B), Gross Ton
14769 - Convention (Subpart B), Net Ton
39418 - Dead Weight, Ton
51309 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 8

15 December 2025 In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8283458
6 December 2025 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8278437
10 October 2024 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8017206
14 June 2024 Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7935077
21 April 2024 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7898822
29 February 2024 Deficiency Check · PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7871632
27 February 2024 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7871194
26 February 2024 Deficiency Check · PSC B · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7870095

Deficiency record · 5

04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 15 December 2025 Resolved
Where emergency source of power is a generator, it shall be started automatically... PSCO observed portable generator installation (approved by flag and class) not capable of automatic start. SOLAS 74 (2014) II-1/43.3.1.2
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 13 January 2026
Resolved 14 January 2026
Resolution: Stisfactory Ro report submitted.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 February 2024 Resolved
FIRE EXTINGUISHING APPLIANCES SHALL BE KEPT IN GOOD ORDER AND BE AVAILABLE FOR IMMEDIATE USE AT ALL TIMES. PSCO OBSERVED LOOSE VALVE ACTUATORS ON MULTIPLE CO2 CYLINDERS ON VESSELS FIXED HIGH PRESSURE CO2 SYSTEM.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 February 2024
Resolution: HOUSTON PSC RECIEVED TECH & CLASS REPORT STATING VESSELS FIXED HIGH PRESSURE CO2 SYSTEM IS FULLY OPERATIONAL. TECH REPORT AND CLASS REPORT IN DOCUMENTS.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 26 February 2024 Resolved
EVERY OIL FUEL PIPE, WHICH, IF DAMAGED, WOULD ALLOW OIL TO ESCAPE FROM A STORAGE, SETTLING, OR DAILY SERVICE TANK SHALL BE FITTED WITH A COCK OR VALVE DIRECTLY ON THE TANK CAPABLE OF BEING CLOSED FROM A SAFE POSITION OUTSIDE THE SPACE. PSCO OBSERVED THE MDO SERVICE TANK AND DAILY LUBE OIL TANK'S QUICK CLOSING ARRANGEMENT USE AND NOT RESET FOR READILY AVAILABLE USE. BOTH THE FUEL OIL AND LUBE OIL VALVES WERE IN THE OPEN POSITION.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 February 2024
Resolved 26 February 2024
Resolution: VALVES WERE RESET.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 February 2024 Resolved
A MAIN ELECTRIC LIGHTING SYSTEM WHICH SHALL PROVIDE ILLUMINATION THROUGHOUT THOSE PARTS OF THE SHIP NORMALLY ACCESSIBLE TO AND USED BY PASSENGERS OR CREW SHALL BE SUPPLIED FROM THE MAIN SOURCE OF ELECTRICAL POWER. PSCO OBSERVED MULTIPLE EMERGENCY AND COMMON ELECTRICAL LIGHTS EXTINGUISHED. ADDITIONALLY CASING WERE FOUND TO BE CRACKED.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 February 2024
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 26 February 2024 Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. PSCO OBSERVED SEVERE WASTAGE TO CARGO LASHING PLATFORMS CREATING HOLES IN THE DECK PLATING. ADDITIONALLY PSCO OBSERVED MISSING SAFETY CHAINS AND MIDDLE/BOTTOM RUNGS MISSING FROM RAILINGS IN-BETWEEN CARGO HOLDS. FINALLY, PSCO OBSERVED DOGS ON MULTIPLE CARGO HOLDS NATURAL VENTILATION HATCHES SEIZED REQUIRING CREW MEMBERS TO USE A HAMMER TO OPERATE.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 26 May 2024
Resolved 14 June 2024
Resolution: Vessel crew cropped and renewed portions of deck and added safety chains between cargo holds.

Ownership record