MAURY USCG vessel records
← All vessels

THE GETAWAY

Built
2003
Last inspected
17 April 2025
Documentation
Expired · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 17 April 2025
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDL5044
675196
Flag
UNITED STATES
Maury page id
psix-675196

Documentation record

Registered dimensions (L × B × D)39.3 ft × 10.0 ft × 6.3 ft
Registered tonnagegross 16 / net 13
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSAFE BOATS INTERNATIONAL LLC · PORT ORCHARD, WA, UNITED STATES · built 2003
Hull materialAluminum
PropulsionJet Drive
Hull shapeShip
Hull configurationMonohull
Hailing portKONA, HI
Endorsements, as the file codes themcw_un
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it16 - Simplified, Gross Ton
13 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 20 inspections, each with its date, unit and type; 39 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 1 other vessel inspected with it; 2 other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

KUOKOA KAI Passenger (Inspected) · MISLE 1097310 · 24 June 2018 · activity 6490727

Inspection history · 20

17 April 2025 Annual Inspection · Drydock Exam
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8113092
16 April 2024 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7895885
17 May 2023 DAPI Audit · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7690868
30 March 2023 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7659993
5 October 2022 In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7571666
14 April 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7403593
18 November 2021 In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7353334
13 April 2021 COI Inspection · Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7174036
2 April 2021 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7167785
23 December 2020 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7115843
10 June 2020 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6973130
19 April 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6666240
16 April 2019 Drydock Exam · COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6665006
24 June 2018 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6490727
23 May 2018 Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6421681
16 August 2017 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6248812
7 June 2017 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6168735
4 April 2017 Annual Inspection · Administrative Inspection · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6132509
29 November 2016 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6049283
10 May 2016 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5922726

Deficiency record · 39

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 April 2024 Resolved
A pre-engineered fixed gas fire extinguishing system must automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. Starboard engine did not shutdown when pre-engineered fixed gas fire extinguishing system tested. Provide operational shutdown for re-engineered fixed gas fire extinguishing system. 46 CFR 181.420(a)(3)
Action required: 10 - Deficiency Rectified
Resolved 16 April 2024
Resolution: Demonstrated proper of fixed gas fire extinguishing system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 April 2024 Resolved
Gauges to indicate engine revolutions per minute (RPM), jacket water discharge temp, and lube oil pressure must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station. RPM gauge starboard side engine not operational. Make RPM gauge operational. 46 CFR 182.410(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2024
Resolved 22 May 2024
Resolution: New gauges provided.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 30 March 2023 Resolved
At each inspection of a vessel, the owner or managing operator shall be prepared to conduct tests including the following: Inspection and operation of through hull fittings and sea valves. Port side raw water through hull valve handle blocked by framing preventing ball valve from fully closing. Provide valve that fully closes through hull penetration. 46 CFR 176.802(a)(2)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 April 2023
Resolution: Valve handle cut and now valve fully closes.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 March 2023 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Vessel has both adult and child life jackets in same location. Properly mark child size life jacket stowage and ensure they are separated from the adult life jackets. 46 CFR 180.78
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2023
Resolved 24 April 2023
Resolution: Child life jacket stowage marked.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 March 2023 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. Marking not provided on exterior of space where life jackets stowed. Provide proper marking on exterior of container. 46 CFR 185.604(f)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2023
Resolved 24 April 2023
Resolution: Marking provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 March 2023 Resolved
Electrical equipment must be installed to protect from electrical hazards. Electrical wiring above helm has exposed and dead end wires. Electrical wire starboard side forward exposed and dead end. Properly remove or renew to make operational to prevent potential shock or fire hazards. 46 CFR 183.200
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2023
Resolved 9 May 2023
Resolution: Electrical wiring removed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 30 March 2023 Resolved
A hatch exposed to the weather must be watertight. Missing screws and securing devices/handles for inspection hatches. Hatch port side upper missing screws, and a few hatches missing securing handles allowing for water intrusion. Provide secure hatches and handle for each hatch. 46 CFR 179.360
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2023
Resolved 24 April 2023
Resolution: New hatches provided.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 March 2023 Resolved
A pre-engineered fixed gas fire extinguishing system must: Be installed in accordance with the manufacturer's instructions. Helm station alarm panel did not have the green pre-discharge light operational. Provide an operational light controller. 46 CFR 181.420 (a)(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2023
Resolved 24 April 2023
Resolution: New alarm panel provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 March 2023 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2023
Resolved 17 May 2023
Resolution: DAPI Audit conducted.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 April 2022 Resolved
All vessels must have navigation lights that are in compliance with Navigation Rules. Port side navigation light not operational. Provide operational Port nav light. No nighttime operations until corrected. 46 CFR 183.420
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2022
Resolution: New nav light installed.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 14 April 2022 Resolved
Each watertight bulkhead must be of sufficient strength to be capable of remaining watertight. Forward hull chain locker/loading door holed above waterline. 02 pin holes located on hull/bulkhead. Make permanent repairs to hull/bulkhead. 46 CFR 179.320
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2022
Resolved 14 May 2022
Resolution: Welded bulkhead.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 April 2022 Resolved
Vessel shall have at least 03 2.5 gallon fire buckets. Buckets onboard were 5 gallons. provide 2.5 gallon buckets. 46 CFR 181.610
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2022
Resolved 13 May 2022
Resolution: New buckets provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 April 2022 Resolved
Vessel does not currently meet the requirements of Work Instruction 31. Mandated crew posted on COI may not enter the water or act as lifeguard until policy and procedure provided. Provide written procedure. Work Instruction 31
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2022
Resolved 14 May 2022
Resolution: Work Instruction 31 Procedures provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 April 2022 Resolved
An adult life jacket must be carried for each person. Missing 01 life jacket. Provide 01 life jacket. Reduction in passenger count to 21. 46 CFR 180.71
Action required: 705 - Other - as specified
Resolved 12 May 2022
Resolution: Adult life jacket provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 April 2022 Resolved
The number and identification of the items stowed inside and their sizes must be marked in clearly legible 2 inch letters. Marking missing for life jackets in compartment forward of helm. Provide marking for life jackets. 46 CFR 185.604
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2022
Resolved 12 May 2022
Resolution: Marking provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 April 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers and crew from electrical hazards. Dead end wire found in the port starboard forward compartment. Remove unused electrical wiring and associated circuit protection and labeling. 46 CFR 183.200
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2022
Resolved 12 May 2022
Resolution: Unused electrical wiring and associated circuit protection and labeling removed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 April 2022 Resolved
Fuel shutoff stations must be marked in 1 inch clearly legible letters indication purpose of the valve. Fuel shutoff valve station not marked. Provide marking to show where fuel shutoff station is located. 46 CFR 185.608
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2022
Resolved 12 May 2022
Resolution: Marking provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 April 2022 Resolved
Battery installation must be protected from falling object. Batteries not in any box. Provide battery box for batteries. 46 CFR 183.354
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2022
Resolved 12 May 2022
Resolution: Battery box provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 April 2022 Resolved
Equipment installed must be suitable for the vessel and its operation and for the purpose intended. Both port and starboard reverse cylinder rams at transom showing severe corrosion. Either conduct thickness gauging or replace with new material. 46 CFR 182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2022
Resolved 31 May 2022
Resolution: Gauging report provided by third party mechanic. Corroded material is .223.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 April 2022 Resolved
Provision must be made for closing all supply and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. Both supply and exhaust openings could not be closed. Provide closure devices for both supply and discharge for ER exhaust. 46 CFR 182.465(h)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 April 2022
Resolution: Vent covers provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 April 2022 Resolved
Each EAP education program must include at least the following elements: display and distribution of informational material; display and distribution of a community service hot-line telephone number for crewmember assistance, and display and distribution of the employer's policy regarding drug and alcohol use in the workplace. Employer’s drug and alcohol policy not onboard the vessel. Place a copy of the policy onboard. 46 CFR 16.401(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2022
Resolved 13 May 2022
Resolution: Policy provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 April 2022 Resolved
Each EAP education program must include at least the following elements: display and distribution of informational material; display and distribution of a community service hot-line telephone number for crew member assistance, and display and distribution of the employer's policy regarding drug and alcohol use in the workplace. Hot-line number not posted on vessel. Post hot-line number on vessel. 46 CFR 16.401(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2022
Resolved 14 May 2022
Resolution: Hot-line number provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 April 2021 Resolved
Company/vessel did not have operational drug and alcohol program in place. Provide operational drug and alcohol program along with all associated components of the program. 46 CFR 16
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 April 2021
Resolution: Drug program operational.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 13 April 2021 Resolved
Pre-engineered fixed firefighting system visual and audible alarms not operational. Provide operational visual and audible alarms for the pre-engineered fixed firefighting system. 46 CFR 181.420 (b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 April 2021
Resolution: Alarms operational.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 April 2021 Resolved
Navigation stern light not operational. Provide operational navigation stern light. 33 CFR 83
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 April 2021
Resolution: Stern light operational.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 April 2021 Resolved
Retro-reflective tape missing from ring buoy. Provide retro tape on ring buoy. 46 CFR 185.604 (i)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 April 2021
Resolution: Retro tape provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 April 2021 Resolved
Master did not have FCC Marine Radio Operator Permit during inspection. Provide valid Marine Radio Operator Permit. 47 CFR 13.7
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2021
Resolved 20 April 2021
Resolution: Master provided MROP.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 13 April 2021 Resolved
Chart on vessel outdated. Light list outdated. No tide/current tables on board. Provide chart of area to be navigated, light list, and tide tables. 46 CFR 184.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2021
Resolved 20 April 2021
Resolution: New pubs provided.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 13 April 2021 Resolved
Compass light not operational. Provide operational compass light. 46 CFR 184.402
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2021
Resolved 20 April 2021
Resolution: Compass light provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 April 2021 Resolved
Emergency broadcast placard showing wrong call sign. Update emergency broadcast placard. 46 CFR 184.506
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2021
Resolved 28 May 2021
Resolution: Placard provided.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 13 April 2021 Resolved
Heat shielding on exhaust after turbo missing. Provide heat shielding to ensure minimum risk of injury to personnel. 46 CFR 182.430
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2021
Resolved 11 May 2021
Resolution: Heat shield provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 April 2021 Resolved
Port side power fluid system leaking from reverse cylinder component. Make repairs to stop leak of power fluid system. 46 CFR 182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2021
Resolved 23 April 2021
Resolution: Repair made to power fluid system.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 13 April 2021 Resolved
02 holes found in forward engine room/tank room bulkhead under helm seat. Make engine room/tank room vapor tight to ensure use of pre-engineered firefighting works when deployed and space is water tight to prevent ingress. 46 CFR 179.320
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2021
Resolved 11 May 2021
Resolution: Bulkhead vapor tight.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 13 April 2021 Resolved
Aluminum boat found with plastic hatch from helm to engine room. Remove plastic hatch and provide hatch of same material vessel is constructed of. 46 CFR 177.300
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2021
Resolved 11 May 2021
Resolution: Alumunum hatch provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 April 2021 Resolved
02 through hull ball valve knife edges showing corrosion and valve not fully closing. Provide fully operational through hull ball valves. 46 CFR 176.802
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2021
Resolved 23 April 2021
Resolution: New ball valves installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 April 2021 Resolved
Vessel FCC station license and safety certificate not updated with new vessel name and ownership. Provide updated FCC documents. 47 CFR 80.13
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2021
Resolved 27 May 2021
Resolution: FCC docs provided.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 June 2020 Resolved
Pre-engineered fire extinguishing system must have an audible alarm upon discharge in accordance with 46 CFR 181.420. Pre-engineered fire extinguishing system audible alarm failed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 December 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 June 2020 Resolved
A visual indicator must be provided at operating station to indicate when automatic bilge pump is running in accordance with 46 CFR 182.530. Engine compartment automatic bilge pump did not have a functioning running light at operating station.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 December 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 April 2019 Resolved
05 Personal Flotation Devices (PFDs) were found to be unserviceable. Replace PFDs in accordance with 46 CFR 180.71. Passenger count reduced to 17 passengers.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 April 2019
Resolution: 05 PFDs supplied.

Recorded names · 2

SEA FIRE II (2013), REEF EXPLORER (2017–2018). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.