Records from 2003 to 2026. Most recent: inspection, 18 May 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 31
18 May 2026
Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8354571
29 April 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8124079
2 May 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7895620
21 February 2024
Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7866115
23 May 2023
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7683871
18 April 2022
COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7430122
15 April 2022
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7431688
28 March 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7420509
24 May 2021
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7206510
24 June 2020
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6986519
25 March 2020
Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6931459
4 June 2019
DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6703023
5 June 2018
DAPI Audit · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6427997
6 February 2018
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6350093
19 June 2017
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6176512
11 February 2016
Hull Examination · Annual Inspection · Internal Structural Exam · DAPI Audit · Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5813217
5 June 2014
DAPI Audit · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4879406
21 June 2012
Simplified Stability Test · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4351328
22 May 2012
Annual Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4319129
27 February 2012
Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4251647
1 December 2011
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4199682
12 November 2010
Type not recorded
No type recorded · Station Atlantic City · USCG East District (CGD-E) · Activity 3890812
9 February 2010
Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3673924
10 June 2008
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3231713
25 February 2008
Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3151746
15 May 2007
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2931338
2 May 2006
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2637902
22 March 2006
Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2606734
25 May 2005
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2367310
7 September 2004
Administrative Inspection
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2190648
30 December 2003
Simplified Stability Test · Construction Oversight · Plan Review "T" Boat · COI Inspection · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2102537
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 May 2026
Resolved
The grab line around the ring life buoy is deteriorated. Replace grab line.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2026
Resolved 2 June 2026
Resolution: New grabine for ring life buoy installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 April 2025
Resolved
Provide positive shutoff valve for stbd side bilge pump.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2025
Resolved 5 May 2025
Resolution: Valve installed,
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 29 April 2025
Resolved
Renew hydrostatic release for EPIRB.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2025
Resolved 5 May 2025
Resolution: New hydrostatic release installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 May 2024
Resolved
A vessel not required to have a power driven fire pump must have at least three (3) two and one half (2.5) gallon buckets, with an attached lanyard, placed as to be easily available during an emergency.
Vessel did not have required fire buckets.
Provide (3) fire buckets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2024
Resolved 3 May 2024
Resolution: Vessel has 3 fire buckets onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boat inventory
Issued 23 May 2023
Resolved
Vessel shall be sufficiently maneuverable, arranged, and equipped to allow the crew to recover a helpless person from the water. Vessel must be equipped to conduct such operation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2023
Resolved 24 May 2023
Resolution: Vessel equipped with lifesling device to recover a helpless person.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 23 May 2023
Resolved
Vessel required to have EPIRB registered. Register EPIRB. Vessel restricted to < 3NM from shore.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2023
Resolved 1 June 2023
Resolution: EPIRB registered to ISLAND TIME
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 23 May 2023
Resolved
Vessel required to have EPIRB marked with vessel name.
Label EPIRB with sticker from registration.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2023
Resolved 1 June 2023
Resolution: EPIRB marked
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 23 May 2023
Resolved
Vessel has expired disposable hydrostatic release for EPIRB. Needs replacement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2023
Resolved 1 June 2023
Resolution: Hydro replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 May 2023
Resolved
An adult life jacket must be provided for each person on
board vessel. Vessel needs (1) Adult FPD. Vessel restricted to 41 adult passengers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2023
Resolved 1 June 2023
Resolution: PFD provided.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 23 May 2023
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2023
Resolved 1 June 2023
Resolution: Vessel received FCC Station License
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 23 May 2023
Resolved
Vessel which transport more than six passengers for hire must have a detail inspection of the radio installation once every 5 years. Vessel needs Communications Act Safety Radiotelephony Certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2023
Resolved 1 June 2023
Resolution: Vsl received FCC Comms Act Certificate
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 May 2023
Resolved
Each life jacket must be marked with the vessel's name in block capital letters. Stencil all FPDs.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2023
Resolved 1 June 2023
Resolution: PFD marked.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 23 May 2023
Resolved
The name of the vessel must be marked in clearly legible letters and numbers on each life float. Mark life float with vessel name.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2023
Resolved 1 June 2023
Resolution: Life float marked
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 May 2023
Resolved
Installation of portable fire extinguishers must be to the satisfaction of the [name withheld] all portable fire extinguisher brackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2023
Resolved 1 June 2023
Resolution: Brackets tightened
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 23 May 2023
Resolved
Each hatch exposed to the weather must be watertight. Tighten both hatches aft.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2023
Resolved 23 August 2023
Resolution: Hatchs are are watertight.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 May 2023
Resolved
Each floating waterlight on a vessel carrying one ring buoy must be attached to the lanyard with a corrosion-resistant clip. Vessel needs corrosion-resistant clip.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2023
Resolved 1 June 2023
Resolution: Corrosion clip provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 April 2022
Resolved
Each ring life buoy with a floating waterlight must secure the waterlight around the body of the ring life buoy. Marine Inspector observed waterlight not attached to ring buoy.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 April 2022
Resolved 5 July 2022
Resolution: operator installed new light to ring buoy.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 April 2022
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of electrical equipment and systems, including the following...Inspection of all lighting fixtures. Marine Inspector 04 observed deck light no operational.
Action required: 705 - Other - as specified
Due 20 April 2022
Resolved 5 July 2022
Resolution: operator installed new deck lights on board.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 18 April 2022
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date Charts of large enough scale to make safe navigation possible.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 April 2022
Resolved 5 July 2022
Resolution: operator sent photo of charts onboard vsl
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 March 2020
Resolved
Install double hose clamps on nonmetallic fuel hoses.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2020
Resolved 5 June 2020
Resolution: Received email with pictures of hose clamps installed.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 19 June 2017
Resolved
EKO01: Provide new retroreflective material for all (8) child life jackets onboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 June 2017
Resolved 20 June 2017
Communications › Radio Communications › VHF Radiotelephone
Issued 16 June 2016
Resolved
Provide DSC capability.
Action required: 705 - Other - as specified
Due 26 August 2016
Resolved 29 June 2016
Resolution: Owner provided e-mail with picture of MMSI number programmed into VHF radio.
Communications › Radio Communications › EPIRB
Issued 22 May 2012
Resolved
Vessel is restricted to operating within 3 miles of shore until NOAA registration for EPIRB is provided.
Action required: 705 - Other - as specified
Due 31 May 2012
Resolved 23 May 2012
Resolution: O/O provided copy of NOAA EPIRB registration showing expiry date of 5/22/14.
Stability › Intact Righting Energy › General
Issued 1 December 2011
Resolved
based on a new Assumed Average Weight per Person (AAWPP) of 185lbs per person. The new regulations came into effect on December 01, 2011 (Federal Register Vol. 75, No. 239). Based on the new AAWPP your vessel has been restricted to the following passenger count: 34 passengers and 2 crew.
Action required: 705 - Other - as specified
Due 14 May 2013
Resolved 14 May 2013
Resolution: Vessel had new stability test on 21 June 2012.
Navigation › Piloting/Steering › Marine Charts
Issued 16 May 2007
Resolved
Update or replace chart #12136.
Condition: Improper/Lack of Maintenance
Due 30 May 2007
Resolved 18 June 2007
Resolution: Received verbal confirmation chart replaced.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 May 2007
Resolved
Replace expired eyewash and aspirin.
Condition: Improper/Lack of Maintenance
Due 30 May 2007
Resolved 18 May 2007
Resolution: Received fax confirming aspirin and eyewash replaced.
Lifesaving › Lifefloat › Lifeline
Issued 15 May 2007
Resolved
Replace grabline and pendants on lifefloat. Vsl restricted from operating limited coastwise until corrected.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 18 June 2007
Resolution: Received electronic photos of replaced grabline and pendants.
Lifesaving › Hand Flares › Not on Board
Issued 15 May 2007
Resolved
Provide 3 orange smoke signals prior to operating limited coastwise.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 18 May 2007
Resolution: Received faxed receipt for 3 orange smoke flares.
Lifesaving › Hand Flares › Quantity
Issued 25 May 2005
Resolved
Provide 3 additional red hand flares and 3 additional orange smokes (total of 6 each should be on board). Vessel restricted to a Lakes, Bays, and Sounds Route until item corrected.
Action required: 705 - Other - as specified
Due 26 June 2005
Resolved 26 May 2005
Resolution: O/O purchased flares and provided receipt for the same. Flares expire in 2008.
Engineering › Fuel Oil Service System › Valve
Issued 25 May 2005
Resolved
Provide emergency shutoff valves for port and starboard engines and label the same.
Action required: 705 - Other - as specified
Due 26 June 2005
Resolved 26 May 2005
Resolution: O/O installed shutoff valves at each filter and labeled "Emergency Fuel Shutoff". Photos and materials invoice included as part of case file.
Electrical › Lighting (service) › Lighting Fixture
Issued 25 May 2005
Resolved
Repair/Replace inoperable overhead light fixture starboard side aft.
Action required: 705 - Other - as specified
Due 25 June 2005
Resolved 30 June 2005
Resolution: O/O stated that fixture has been replaced with a new one and that it is operational. Vessel was unavailable for inspection due to being underway.
Communications › Radio Communications › VHF Radiotelephone
Issued 24 June 2004
Resolved
Provide FCC operator permits for Masters.
Due 1 August 2004
Resolved 15 July 2004
Resolution: Received fax copy of satisfactory FCC test results for [name withheld] and [name withheld].
Communications › Radio Communications › VHF Radiotelephone
Issued 24 June 2004
Resolved
Provide valid FCC safety certificate.
Due 24 July 2004
Resolved 15 July 2004
Resolution: Received fax copy of Safety Certificate issued 07JUL04 to expire on 07JUL09 for FISH FINDER II.